Manual · Microscan
Microscan Edge-to-Edge Backlight Manual
Manual2 pagesPDF 296 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Two-page configuration guide (P/N 83-230006 Rev C) for the Nerlite Edge-to-Edge Backlight Series illuminators. It lists the backlight versions by size, color and continuous or strobe operation, the hardware needed to run them, and how to wire them to a power supply or an NL-2XX series lighting controller.
- What it is
- Backlight illuminators for continuous or strobe operation p. 1
- Sizes
- BL 47X59, BL 71X88, BL 100X100 and BL 50X200 p. 1
- Colors
- Red, white, blue and infrared versions, in continuous and strobe types p. 1
- Part numbers
- NER-011659300G to NER-011659641G p. 1
- Power
- Lights that need no controller: 24VDC +/- 1%; NL-2XX controllers: 24 to 48VDC p. 2
- Connector
- 4 pin male M12 on M12 models: pin 1 positive, pin 3 negative, shell to chassis ground, pins 2 and 4 unused p. 2
- Hardware
- Backlight; DSP60 24VDC 2.5A DIN mount power supply; NL-200 series lighting controller; 4 pin M12 female to flying leads cable p. 1
- Cable
- M12F to flying leads, 4.5M [15FT], connects the backlight to the power supply or controller p. 2
- Strobe limits
- At maximum rated current: pulse width 1mS maximum, duty cycle 6% maximum p. 2
- Power cords
- AC power cords for the power supply in US, EU and UK versions p. 2
What this manual walks you through
- Choosing a backlight by size, color and continuous or strobe operation p. 1
- Connecting a backlight to a power supply alone or with an NL-200 controller p. 1
- Setting the strobe current on an NL-2XX lighting controller p. 2
- Wiring flying leads and M12 connectors to the supply or controller p. 2
Good to know
- With an NL-2XX controller in strobe mode, set the current rating to 10% of the light's specified current; then 1000% brightness gives 100% of rated current. p. 2
- Models with separate fan circuits need 24VDC on the fan circuit at all times while the light runs. p. 2
- Some lights need both channels of the NL-2XX controller, and the two channels may need different current settings. p. 2
Questions this manual answers
How do I wire the M12 connector of a Nerlite edge-to-edge backlight?
Pin 1 goes to the positive output of the power supply or controller, pin 3 to the negative output, and the shell to chassis ground; pins 2 and 4 are not used. p. 2
What voltage does the edge-to-edge backlight need?
Lights that need no controller take 24VDC +/- 1%; the NL-2XX series controllers take 24 to 48VDC. p. 2
How do I set the strobe current on an NL-2XX controller for this backlight?
Set the current rating to 10% of the current the guide specifies for the light, so that 1000% brightness gives full rated current without damage. p. 2
What sizes does the edge-to-edge backlight come in?
BL 47X59, BL 71X88, BL 100X100 and BL 50X200. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Nerlite Edge-to-Edge Backlight Series Illuminators Configuration Guide
Continuous Operation Part Number NER-011659300G
Description
Continuous Current
BNER-011659300Gontinuous
NER-011659301GNER-011659301GobeNER-011659310G
BNER-011659310Gontinuous
NER-011659311GBL 47X59 White StrobeNER-011659320G
BL 47X59 Blue Continuous
NER-011659321GBL 47X59 Blue StrobeStrobe Current93mANANA2.67A201mANANA3.34A170mANANA3.00ANER-011659340G
BL 47X59 Infrared Continuous
140mANANER-011659341G
BL 47X59 Infrared Strobe
NA4.00ANER-011659400G
BL 71X88 Red Continuous
170mANANER-011659401GBL 71X88 Red StrobeNER-011659410G
BL 71X88 White Continuous
NER-011659411GBL 71X88 White StrobeNER-011659420G
BL 71X88 Blue Continuous
NER-011659421GBL 71X88 Blue StrobeNER-011659440G
BL 71X88 Infrared Continuous
NER-011659441G
BL 71X88 Infrared Strobe
NER-011659500G
BL 100X100 Red Continuous
NER-011659501GBL 100X100 Red StrobeNER-011659510G
BL 100X100 White Continuous
NER-011659511G
BL 100X100 White Strobe
NER-011659520G
BL 100X100 Blue Strobe BL 100X100 Infrared Continuous
5.01A NANA9.00A310mANANA9.00A220mANANA7.50A155mANANA
BL 100X100 Blue Continuous
NER-011659521G NER-011659540G
NA 330mANANA9.98A320mANANA9.98A250mANANER-011659541G
BL 100X100 Infrared Strobe
NA
7.99A
BL 50X200 Red Continuous
155mANANER-011659601G
BL 50X200 Red Strobe BL 50X200 White Continuous
NER-011659611GBL 50X200 White StrobeNER-011659620G
BL 50X200 Blue Continuous
NER-011659621GBL 50X200 Blue StrobeNER-011659640G
BL 50X200 Infrared Continuous
NER-011659641G
BL 50X200 Infrared Strobe
NA4.99A350mANANA9.98A320mANANA
NL-2XX Optional (Used only if Intensity and/or Ethernet Control Is Desired)
Figure AFigure BFigure AFigure BFigure AFigure BFigure AFigure BNANA7.99ANL-2XX (Required)7 7 7 7 Figure BFigure AFigure BFigure AFigure B7 7Figure B7Figure B77 7 Figure BFigure AFigure BFigure AFigure BFigure AFigure BFigure AFigure B7 7Figure B7 7Figure BFigure AFigure BFigure AFigure BFigure AFigure BFigure AFigure BFigure AFigure BFigure AFigure B
Connection Notes Reference Number (See the Connection Notes on back of page)
7 Figure B7 7Figure B7Figure B77 7 Figure B7 7Figure B7 7Figure B7 7Figure B9.98A250mAStrobe OperationFigure B4.99A350mA
NER-011659600G NER-011659610G
Fan Cooled
No Controller Required (Can be Connectet Directly to 24VDC)
7 7Figure B7Figure B77
If using this product in strobe mode with an NL-2XX Series Lighting Controller, refer to the warning on the back of this document.
Hardware Required Item 1 2 3 4
1
Description Edge-To-Edge Series Backlights Power Supply DSP60 24VDC 2.5A DIN Mount NL-200 Series Lighting Controller Cable 4 Pin M12 Female To Flying Leads
Part Number NER-011659XXXG NER-011504100 98-000152-0X NER-030029100
3
Figure A Edge-to-Edge Backlight Series Illuminator with power supply
2- POWER + INPUT2
- 12V. 1.4A (UNFUSED)
- POWER OUTPUT
4
Figure B Edge-to-Edge Backlight Series Illuminator with NL-200 and power supply
14P/N 83-230006 Rev C
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
NERLITE Edge-to-Edge Backlight Series Illuminators
AC Power Cord US AC Power Cord EU AC Power Cord UK CBL, M12F-FLYING LEADS, 4.5M [15FT]
NER-030028300 NER-030028400 NER-030028500 NER-030029100
Power Cord For Power Supply Power Cord For Power Supply Power Cord For Power Supply Connect Backlight To Power Supply Or Controller
WARNING! When connecting a strobe light to an NL-2XX Series Lighting Controller, you must set the current rating to 10% of the current specified for the light in this document. The NL-2XX Series Controller allows the operator to set the brightness (current) to 1000% in strobe mode. By setting the initial current rating to 10% of the light’s specified current, a brightness setting of 1000% results in the light receiving 100% of its rated current. This will provide maximum light output without damaging the light. Note: Certain lights require both channels of the NL-2XX Series Lighting Controller. Channel 1 and Channel 2 may have different current specifications on some models. Be sure each channel is set correctly as specified in this document. General Notes: 1. Those lights that do not require a controller require 24VDC +/- 1%. 2. The NL-2XX series controllers require 24 to 48VDC. 3. The cable on all flying lead models is terminated with three, five, or seven leads. Each lead is labeled. See “Connection Notes” for connection instructions. 4. For all models with M12 connectors, the connector is a 4 pin, male, M12 connector. See “Connection Notes” or connector pin out and connection instructions. 5. All models with separate fan circuits must have 24VDC connected to the fan circuit at all times when the light is operating. 6. When operating in strobe mode at the maximum rated current, the maximum pulse width = 1mS and the maximum duty cycle = 6%. See the NL-2XX series controllers’ manual for pulse width and duty cycle limitations under various conditions. Connection Notes: 1. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” or “SHLD” to chassis ground. 2. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the power supply or controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground. 3. Connect the lead labeled “V+1” to the positive(+) output terminal of channel 1 on an NL-2XX series controller. Connect the lead labeled “GND1” to the negative(-) output terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “V+2” to the positive(+) outpt terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “GND2” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Shield” to chassis ground 4. Connect the lead labeled “+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “-” to the negative(-) output terminal of the power supply or controller. Connect the cable’s braided shield to chassis ground. 5. Connect the lead labeled “DOAL V+” to the positive(+) output terminal of channel 1 on an NL-2XX series controller. Connect the lead labeled “DOAL GND” to the negative(-) output terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “Ring V+” to the positive(+) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Ring GND” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground. 6. Connect the two leads labeled “RING 1, 2 V+” & “RING 3 V+” to the same positive(+) output terminal of the power supply or controller. Connect the two leads labeled “RING 1, 2 -” & “RING 3 -” to the same negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” to chassis ground. 7. Connect Pin 1 of the M12-M connector to the positive(+) output terminal of the power supply or controller. Connect Pin 3 of the M12-M connector to the negative(-) output terminal of the power supply or controller. Connect the shell of the M12-M connector to chassis ground. Pins 2 and 4 are not used.