Two-page configuration guide (P/N 83-230006 Rev C) for the Nerlite Edge-to-Edge Backlight Series illuminators. It lists the backlight versions by size, color and continuous or strobe operation, the hardware needed to run them, and how to wire them to a power supply or an NL-2XX series lighting controller.

What it is
Backlight illuminators for continuous or strobe operation p. 1
Sizes
BL 47X59, BL 71X88, BL 100X100 and BL 50X200 p. 1
Colors
Red, white, blue and infrared versions, in continuous and strobe types p. 1
Part numbers
NER-011659300G to NER-011659641G p. 1
Power
Lights that need no controller: 24VDC +/- 1%; NL-2XX controllers: 24 to 48VDC p. 2
Connector
4 pin male M12 on M12 models: pin 1 positive, pin 3 negative, shell to chassis ground, pins 2 and 4 unused p. 2
Hardware
Backlight; DSP60 24VDC 2.5A DIN mount power supply; NL-200 series lighting controller; 4 pin M12 female to flying leads cable p. 1
Cable
M12F to flying leads, 4.5M [15FT], connects the backlight to the power supply or controller p. 2
Strobe limits
At maximum rated current: pulse width 1mS maximum, duty cycle 6% maximum p. 2
Power cords
AC power cords for the power supply in US, EU and UK versions p. 2

What this manual walks you through

  • Choosing a backlight by size, color and continuous or strobe operation p. 1
  • Connecting a backlight to a power supply alone or with an NL-200 controller p. 1
  • Setting the strobe current on an NL-2XX lighting controller p. 2
  • Wiring flying leads and M12 connectors to the supply or controller p. 2

Good to know

  • With an NL-2XX controller in strobe mode, set the current rating to 10% of the light's specified current; then 1000% brightness gives 100% of rated current. p. 2
  • Models with separate fan circuits need 24VDC on the fan circuit at all times while the light runs. p. 2
  • Some lights need both channels of the NL-2XX controller, and the two channels may need different current settings. p. 2

Questions this manual answers

How do I wire the M12 connector of a Nerlite edge-to-edge backlight?

Pin 1 goes to the positive output of the power supply or controller, pin 3 to the negative output, and the shell to chassis ground; pins 2 and 4 are not used. p. 2

What voltage does the edge-to-edge backlight need?

Lights that need no controller take 24VDC +/- 1%; the NL-2XX series controllers take 24 to 48VDC. p. 2

How do I set the strobe current on an NL-2XX controller for this backlight?

Set the current rating to 10% of the current the guide specifies for the light, so that 1000% brightness gives full rated current without damage. p. 2

What sizes does the edge-to-edge backlight come in?

BL 47X59, BL 71X88, BL 100X100 and BL 50X200. p. 1

The file

Size and text

Pages2
PDF296 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Microscan Edge-to-Edge Backlight Manual

The text of page 1, from the PDF itself

Nerlite Edge-to-Edge Backlight Series Illuminators Configuration Guide

Continuous Operation Part Number NER-011659300G

Description

Continuous Current

BNER-011659300Gontinuous

NER-011659301GNER-011659301GobeNER-011659310G

BNER-011659310Gontinuous

NER-011659311GBL 47X59 White StrobeNER-011659320G

BL 47X59 Blue Continuous

NER-011659321GBL 47X59 Blue StrobeStrobe Current93mANANA2.67A201mANANA3.34A170mANANA3.00ANER-011659340G

BL 47X59 Infrared Continuous

140mANANER-011659341G

BL 47X59 Infrared Strobe

NA4.00ANER-011659400G

BL 71X88 Red Continuous

170mANANER-011659401GBL 71X88 Red StrobeNER-011659410G

BL 71X88 White Continuous

NER-011659411GBL 71X88 White StrobeNER-011659420G

BL 71X88 Blue Continuous

NER-011659421GBL 71X88 Blue StrobeNER-011659440G

BL 71X88 Infrared Continuous

NER-011659441G

BL 71X88 Infrared Strobe

NER-011659500G

BL 100X100 Red Continuous

NER-011659501GBL 100X100 Red StrobeNER-011659510G

BL 100X100 White Continuous

NER-011659511G

BL 100X100 White Strobe

NER-011659520G

BL 100X100 Blue Strobe BL 100X100 Infrared Continuous

5.01A NANA9.00A310mANANA9.00A220mANANA7.50A155mANANA

BL 100X100 Blue Continuous

NER-011659521G NER-011659540G

NA 330mANANA9.98A320mANANA9.98A250mANANER-011659541G

BL 100X100 Infrared Strobe

NA

7.99A

BL 50X200 Red Continuous

155mANANER-011659601G

BL 50X200 Red Strobe BL 50X200 White Continuous

NER-011659611GBL 50X200 White StrobeNER-011659620G

BL 50X200 Blue Continuous

NER-011659621GBL 50X200 Blue StrobeNER-011659640G

BL 50X200 Infrared Continuous

NER-011659641G

BL 50X200 Infrared Strobe

NA4.99A350mANANA9.98A320mANANA

NL-2XX Optional (Used only if Intensity and/or Ethernet Control Is Desired)

Figure AFigure BFigure AFigure BFigure AFigure BFigure AFigure BNANA7.99ANL-2XX (Required)7 7 7 7 Figure BFigure AFigure BFigure AFigure B7 7Figure B7Figure B77 7 Figure BFigure AFigure BFigure AFigure BFigure AFigure BFigure AFigure B7 7Figure B7 7Figure BFigure AFigure BFigure AFigure BFigure AFigure BFigure AFigure BFigure AFigure BFigure AFigure B

Connection Notes Reference Number (See the Connection Notes on back of page)

7 Figure B7 7Figure B7Figure B77 7 Figure B7 7Figure B7 7Figure B7 7Figure B9.98A250mAStrobe OperationFigure B4.99A350mA

NER-011659600G NER-011659610G

Fan Cooled

No Controller Required (Can be Connectet Directly to 24VDC)

7 7Figure B7Figure B77

If using this product in strobe mode with an NL-2XX Series Lighting Controller, refer to the warning on the back of this document.

Hardware Required Item 1 2 3 4

1

Description Edge-To-Edge Series Backlights Power Supply DSP60 24VDC 2.5A DIN Mount NL-200 Series Lighting Controller Cable 4 Pin M12 Female To Flying Leads

Part Number NER-011659XXXG NER-011504100 98-000152-0X NER-030029100

3

Figure A Edge-to-Edge Backlight Series Illuminator with power supply

2- POWER + INPUT2

  • 12V. 1.4A (UNFUSED)
  • POWER OUTPUT

4

Figure B Edge-to-Edge Backlight Series Illuminator with NL-200 and power supply

14P/N 83-230006 Rev C

Page 2 of Microscan Edge-to-Edge Backlight Manual

The text of page 2, from the PDF itself

NERLITE Edge-to-Edge Backlight Series Illuminators

AC Power Cord US AC Power Cord EU AC Power Cord UK CBL, M12F-FLYING LEADS, 4.5M [15FT]

NER-030028300 NER-030028400 NER-030028500 NER-030029100

Power Cord For Power Supply Power Cord For Power Supply Power Cord For Power Supply Connect Backlight To Power Supply Or Controller

WARNING! When connecting a strobe light to an NL-2XX Series Lighting Controller, you must set the current rating to 10% of the current specified for the light in this document. The NL-2XX Series Controller allows the operator to set the brightness (current) to 1000% in strobe mode. By setting the initial current rating to 10% of the light’s specified current, a brightness setting of 1000% results in the light receiving 100% of its rated current. This will provide maximum light output without damaging the light. Note: Certain lights require both channels of the NL-2XX Series Lighting Controller. Channel 1 and Channel 2 may have different current specifications on some models. Be sure each channel is set correctly as specified in this document. General Notes: 1. Those lights that do not require a controller require 24VDC +/- 1%. 2. The NL-2XX series controllers require 24 to 48VDC. 3. The cable on all flying lead models is terminated with three, five, or seven leads. Each lead is labeled. See “Connection Notes” for connection instructions. 4. For all models with M12 connectors, the connector is a 4 pin, male, M12 connector. See “Connection Notes” or connector pin out and connection instructions. 5. All models with separate fan circuits must have 24VDC connected to the fan circuit at all times when the light is operating. 6. When operating in strobe mode at the maximum rated current, the maximum pulse width = 1mS and the maximum duty cycle = 6%. See the NL-2XX series controllers’ manual for pulse width and duty cycle limitations under various conditions. Connection Notes: 1. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” or “SHLD” to chassis ground. 2. Connect the lead labeled “V+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “GND” to the negative(-) output terminal of the power supply or controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground. 3. Connect the lead labeled “V+1” to the positive(+) output terminal of channel 1 on an NL-2XX series controller. Connect the lead labeled “GND1” to the negative(-) output terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “V+2” to the positive(+) outpt terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “GND2” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Shield” to chassis ground 4. Connect the lead labeled “+” to the positive(+) output terminal of the power supply or controller. Connect the lead labeled “-” to the negative(-) output terminal of the power supply or controller. Connect the cable’s braided shield to chassis ground. 5. Connect the lead labeled “DOAL V+” to the positive(+) output terminal of channel 1 on an NL-2XX series controller. Connect the lead labeled “DOAL GND” to the negative(-) output terminal of channel 1 on the NL-2XX series controller. Connect the lead labeled “Ring V+” to the positive(+) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Ring GND” to the negative(-) output terminal of channel 2 on the NL-2XX series controller. Connect the lead labeled “Fan V+” to the positive(+) output terminal of a 24VDC power supply. Connect the lead labeled “Fan GND” to the negative(-) output terminal of a 24VDC power supply. Connect the lead labeled “Shield” to chassis ground. 6. Connect the two leads labeled “RING 1, 2 V+” & “RING 3 V+” to the same positive(+) output terminal of the power supply or controller. Connect the two leads labeled “RING 1, 2 -” & “RING 3 -” to the same negative(-) output terminal of the power supply or controller. Connect the lead labeled “Shield” to chassis ground. 7. Connect Pin 1 of the M12-M connector to the positive(+) output terminal of the power supply or controller. Connect Pin 3 of the M12-M connector to the negative(-) output terminal of the power supply or controller. Connect the shell of the M12-M connector to chassis ground. Pins 2 and 4 are not used.