Spec sheet · Microscan
Microscan DN-120 Spec Sheet
Spec sheet1 pagePDF 89 KB
The page is below, with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A one-page Microscan data sheet (Rev. A 09/07) for the DN-120 DeviceNet interface box, which connects a Microscan RS-232 bar code reader to a DeviceNet network. It gives the mechanical, electrical, environmental and communication specifications and the pinouts of the scanner and host connectors.
- Device
- DeviceNet interface box: an RS-232 to DeviceNet serial gateway for Microscan RS-232 bar code readers p. 1
- Power
- 11-28 VDC at 50 mA p. 1
- Connectors
- Scanner connector DB-9 plug; host connector 5-pin MicroChange p. 1
- Host pinout
- 1 Drain, 2 Bus +, 3 Bus –, 4 CAN H, 5 CAN L p. 1
- Scanner pinout
- 2 Receive data RS-232 (in), 3 Transmit data RS-232 (out), 5 Ground, 7 Request-to-send RS-232 (out), 8 Clear-to-send RS-232 (in); 1, 4, 6, 9 NC p. 1
- Setup
- Mac ID and serial channel set by rotary switch or software p. 1
- Baud rates
- 300, 1200, 2400, 4800, 9600, 19.2K (software/hardware selected) p. 1
- Serial format
- 8 or 7 data bits (set by parity); parity even, odd or none; 1 stop bit (fixed); flow control none, RTS/CTS or X-on/X-off p. 1
- Isolation
- Fully isolated RS-232 serial channel, 500V; loss-of-ground protection p. 1
- Protection
- Reverse polarity -30 VDC; ESD ±10 kv; overload ±30 V; short circuit indefinite p. 1
- Signal levels
- ISO 11898; output levels ±7.9V (typical) p. 1
- Dimensions
- 3.25” (82.6 mm) long, 2.5” (63.5 mm) wide, 1.08” (27.4 mm) high p. 1
- Environment
- Plastic housing; operating temperature 0° to 70° C (32° to 158°F) p. 1
Questions this sheet answers
What voltage does the Microscan DN-120 need?
11-28 VDC at 50 mA. p. 1
What baud rates does the DN-120 serial port support?
300, 1200, 2400, 4800, 9600 and 19.2K, selected in software or hardware. p. 1
How is the DeviceNet Mac ID set on the DN-120?
With the rotary switches, or in software. p. 1
What connector does the DN-120 use for the DeviceNet network?
A 5-pin MicroChange host connector: pin 1 drain, 2 Bus +, 3 Bus –, 4 CAN H, 5 CAN L. p. 1
The file
Size and text
Every page · 1
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 1
Open in the PDF
The text of page 1, from the PDF itself
DeviceNetInterface BoxReader Connector
DeviceNet is a communication protocol managed by the Open DeviceNet Vendors Association (ODVA), with Controller Area Network (CAN) as the backbone technology. The protocol is used in the automation industry as a quick and economical way to network a variety of devices.
Host Connector
The DeviceNet DN-120 interface box easily connects any Microscan RS-232 bar code reader to a DeviceNet network. Mac ID and serial channel are rotary switch selectable or software configurable. Other DeviceNet interface box features include a loss-ofground protection circuit, fully isolated RS232 serial channel, and selectable serial baud rate (300 to 19.2k). For more information on this product, visit www.microscan.com.
MECHANICAL
CONNECTORS
Length: 3.25” (82.6 mm) Width: 2.5” (63.5 mm) Height: 1.08” (27.4 mm)
Scanner Connector: DB-9 plug
ELECTRICAL Voltage: 11-28 VDC at 50 mA Loss-of-ground Protection: Yes Reverse Polarity: -30 VDC Signal Levels: ISO 11898 Isolation: 500V ESD Protection: ±10 kv Overload Protection: ±30 V° Short Circuit: Indefinite Output Levels: ±7.9V (typical)
ENVIRONMENTAL Enclosure: Plastic housing Operating Temperature: 0° to 70° C (32° to 158°F)
COMMUNICATION Interface: RS-232 Protocols: RS-232 to DeviceNet serial gateway Data Bits: 8, 7 (determined by parity setting) Parity: Even, odd, none (software configurable) Stop Bits: 1 (fixed) Baud Rate: 300, 1200, 2400, 4800, 9600, 19.2K (software/ hardware selected) Flow Control: None, RTS/CTS, X-on/X-off
Pin
ISO 9001:2000 Certified QMS
Function1NCISO CERTIFICATION2
Receive data RS-232 (in)
3
Transmit data RS-232 (out)
Issued by TUV USA Inc, Member of TÜV NORD Group, Cert No. 06–1080
4NC5Ground6NC7
Request-to-send RS-232 (out)
8
Clear-to-send RS-232 (in)
9
NC
©2007 Microscan Systems, Inc. Rev. A 09/07 Warranty–One year limited warranty on parts and labor. Extended warranty available.
Host Connector: 5-pin MicroChange Pin
Function1Drain2Bus +3Bus –4CAN H5CAN L
Microscan Systems, Inc. Tel 425 226 5700 / 800 251 7711 Fax 425 226 8250 Microscan Europe Tel 31 172 423360 / Fax 31 172 423366 Microscan Asia Pacific R.O. Tel 65 6846 1214 / Fax 65 6846 4641 Part of a full range of sales tools available from our website:
www.microscan.com E-mail: i n f o @ m i c r o sc a n . c o m Tech Support: helpdesk@microscan.com