Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Microscan DN-120 Spec Sheet

Spec sheet · Microscan

Microscan DN-120 Spec Sheet

Spec sheet1 pagePDF 89 KB

The page is below, with its text.

Download the PDF89 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

A one-page Microscan data sheet (Rev. A 09/07) for the DN-120 DeviceNet interface box, which connects a Microscan RS-232 bar code reader to a DeviceNet network. It gives the mechanical, electrical, environmental and communication specifications and the pinouts of the scanner and host connectors.

Device
DeviceNet interface box: an RS-232 to DeviceNet serial gateway for Microscan RS-232 bar code readers p. 1
Power
11-28 VDC at 50 mA p. 1
Connectors
Scanner connector DB-9 plug; host connector 5-pin MicroChange p. 1
Host pinout
1 Drain, 2 Bus +, 3 Bus –, 4 CAN H, 5 CAN L p. 1
Scanner pinout
2 Receive data RS-232 (in), 3 Transmit data RS-232 (out), 5 Ground, 7 Request-to-send RS-232 (out), 8 Clear-to-send RS-232 (in); 1, 4, 6, 9 NC p. 1
Setup
Mac ID and serial channel set by rotary switch or software p. 1
Baud rates
300, 1200, 2400, 4800, 9600, 19.2K (software/hardware selected) p. 1
Serial format
8 or 7 data bits (set by parity); parity even, odd or none; 1 stop bit (fixed); flow control none, RTS/CTS or X-on/X-off p. 1
Isolation
Fully isolated RS-232 serial channel, 500V; loss-of-ground protection p. 1
Protection
Reverse polarity -30 VDC; ESD ±10 kv; overload ±30 V; short circuit indefinite p. 1
Signal levels
ISO 11898; output levels ±7.9V (typical) p. 1
Dimensions
3.25” (82.6 mm) long, 2.5” (63.5 mm) wide, 1.08” (27.4 mm) high p. 1
Environment
Plastic housing; operating temperature 0° to 70° C (32° to 158°F) p. 1

Questions this sheet answers

What voltage does the Microscan DN-120 need?

11-28 VDC at 50 mA. p. 1

What baud rates does the DN-120 serial port support?

300, 1200, 2400, 4800, 9600 and 19.2K, selected in software or hardware. p. 1

How is the DeviceNet Mac ID set on the DN-120?

With the rotary switches, or in software. p. 1

What connector does the DN-120 use for the DeviceNet network?

A 5-pin MicroChange host connector: pin 1 drain, 2 Bus +, 3 Bus –, 4 CAN H, 5 CAN L. p. 1

The file

Size and text

Pages1
PDF89 KB
TextText from the PDF itself.

Every page · 1

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Microscan DN-120 Spec Sheet

The text of page 1, from the PDF itself

DeviceNetInterface BoxReader Connector

DeviceNet is a communication protocol managed by the Open DeviceNet Vendors Association (ODVA), with Controller Area Network (CAN) as the backbone technology. The protocol is used in the automation industry as a quick and economical way to network a variety of devices.

Host Connector

The DeviceNet DN-120 interface box easily connects any Microscan RS-232 bar code reader to a DeviceNet network. Mac ID and serial channel are rotary switch selectable or software configurable. Other DeviceNet interface box features include a loss-ofground protection circuit, fully isolated RS232 serial channel, and selectable serial baud rate (300 to 19.2k). For more information on this product, visit www.microscan.com.

MECHANICAL

CONNECTORS

Length: 3.25” (82.6 mm) Width: 2.5” (63.5 mm) Height: 1.08” (27.4 mm)

Scanner Connector: DB-9 plug

ELECTRICAL Voltage: 11-28 VDC at 50 mA Loss-of-ground Protection: Yes Reverse Polarity: -30 VDC Signal Levels: ISO 11898 Isolation: 500V ESD Protection: ±10 kv Overload Protection: ±30 V° Short Circuit: Indefinite Output Levels: ±7.9V (typical)

ENVIRONMENTAL Enclosure: Plastic housing Operating Temperature: 0° to 70° C (32° to 158°F)

COMMUNICATION Interface: RS-232 Protocols: RS-232 to DeviceNet serial gateway Data Bits: 8, 7 (determined by parity setting) Parity: Even, odd, none (software configurable) Stop Bits: 1 (fixed) Baud Rate: 300, 1200, 2400, 4800, 9600, 19.2K (software/ hardware selected) Flow Control: None, RTS/CTS, X-on/X-off

Pin

ISO 9001:2000 Certified QMS

Function1NCISO CERTIFICATION2

Receive data RS-232 (in)

3

Transmit data RS-232 (out)

Issued by TUV USA Inc, Member of TÜV NORD Group, Cert No. 06–1080

4NC5Ground6NC7

Request-to-send RS-232 (out)

8

Clear-to-send RS-232 (in)

9

NC

©2007 Microscan Systems, Inc. Rev. A 09/07 Warranty–One year limited warranty on parts and labor. Extended warranty available.

Host Connector: 5-pin MicroChange Pin

Function1Drain2Bus +3Bus –4CAN H5CAN L

Microscan Systems, Inc. Tel 425 226 5700 / 800 251 7711 Fax 425 226 8250 Microscan Europe Tel 31 172 423360 / Fax 31 172 423366 Microscan Asia Pacific R.O. Tel 65 6846 1214 / Fax 65 6846 4641 Part of a full range of sales tools available from our website:

www.microscan.com E-mail: i n f o @ m i c r o sc a n . c o m Tech Support: helpdesk@microscan.com

More documents · 1