The text of a manual · part 1 of 3
TECH 7 Laser Bar Code Projection Scanner Installation and User's Guide, pages 1 to 10
Pages 1 to 10 of 28
The original document is the PDF (267 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic TECH 7 775 and Metrologic TECH 7 MS770
Page 1
METROLOGIC INSTRUMENTS, INC. TECH 7™ Laser Bar Code Projection Scanner Installation and User’s Guide
MLPN 2159 Printed in USA June 1998
Page 2
Locations:
USA Corporate Headquarters Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012 Customer Service: 1-800-ID-METRO Tel: 609-228-8100 Fax: 609-228-6673 EMAIL: info@metrologic.com INTERNET: http://www.metrologic.com Mailing Address: P.O. Box 307 Bellmawr, NJ 08099-0307
South America Metrologic Instruments Centro Ciudad Comercial Tamanaco Torre B, piso 6, ofic. 603-B Chuao 1064 Caracas, Venezuela Tel: 58-2-959-8911 Fax: 58-2-959-9328 EMAIL: info@sa.metrologic.com
Europe Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany Tel: 49-89-89019-0 Fax: 49-89-89019-200 EMAIL: metrologic@europe.metrologic.com
ASIA Metrologic Asia (PTE) Ltd. 31, Kaki Bukit Road 3 #05-08, Techlink Singapore 417818 Tel: 65-842-7155 Fax: 65-842-7166 EMAIL: ant888@cyberway.com.sg
Brasil Metrologic do Brasil Ltda. Rua Florida, 1821-5 andar Brooklin-Sao Paulo-SP 04571-090 Brasil Tel: (011) 5505-2396 Fax: (011) 5507-2301 EMAIL: metrolog@br.metrologic.com Copyright © 1999 by Metrologic® Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.
ii
Page 3
Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
Unpacking List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
Scanner Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Configuration to the Host System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Stand Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Back Plate Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Parts of the Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Visual Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10 Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Depth of Scan Field for the MS770 Scanner . . . . . . . . . . . . . . . . . . . . . . . . 12 Depth of Scan Field for the MS775 Scanner . . . . . . . . . . . . . . . . . . . . . . . . 13 Applications and Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Appendix A Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15, 16 Appendix B Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17, 18 Appendix C Warranty and Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19, 20 Appendix D Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21, 22 Appendix E Patents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 25 iii
Page 4
Introduction Metrologic’s TECH 7 laser bar code projection scanner is encased in an NEMA-12 steel case. The case construction enables the scanner to operate in harsh surroundings, especially industrial environments. Water-resistant, shock-resistant, and rugged, the TECH 7 is also fast, aggressive and reliable. It can register bar codes at a range of 76mm - 254mm (3" - 10") and can autodiscriminate among all common codes. To suit particular applications, two different scan patterns are available: an omnidirectional pattern of 20 interlocking lines (Model MS770); or a 12-line raster pattern (Model MS775). The scanner has a VLD design, a scan speed of up to 2000 lines per second, and uses less than 8 watts of power. Other features include an Application Specific Integrated Circuit (ASIC) and MECCA© (Metrologic Enhanced Code Correcting Algorithm). An Application Specific Integrated Circuit (ASIC) is in the decoding system and virtually eliminates misreads. MECCA© (Metrologic Enhanced Code Correcting Algorithm) enables the TECH 7 scanner to read poorly printed, wrinkled or even torn bar codes on the first pass.
Unpacking List The shipping carton, should contain the following: ! Installation and User’s Guide (MLPN: 2159) ! ScanSelect Scanner Programming Guide (MLPN: 2186) ! TECH 7 Model MS770 with omnidirectional scan pattern or TECH 7 Model MS775 with raster scan pattern ! Communication Cable with Power Supply (optional) or Communication Cable (optional) ! Back Plate (optional) or Stand (optional) If any item is missing or to order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-IDMETRO or 1-800-436-3876.
1
Page 5
Scanner Installation To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. 1. "Power off" the host system. 2. Locate the 19-pin female end of the scanner link cable and find the widest key located above pins L and A. Align this key with the corresponding key on the scanner box’s Mil spec connector. While pushing in on the connector, rotate the ring clockwise until it locks into place with a click. 3. Connect the other end of the communication cable to the host device. (If the scanner is powered by the host, skip to Step 5.) 4. Check the AC input requirements of the transformer/power supply to make sure the voltage matches an available AC outlet. Plug the transformer into the AC outlet to supply power to the scanner. (A socket-outlet shall be installed near the equipment and shall be easily accessible.) 5. "Power up" the host system. Note: When the scanner first receives power, the LEDs will flash and then the scanner will beep once. After the scanner performs this startup sequence, the green LED will remain on for a specified time indicating that the laser is on.
2
Page 6
Configuration to the Host System The scanner is shipped from the factory programmed to a set of default conditions noted in the ScanSelect Scanner Programming Guide by an asterisk that appears before the brief definition located next to the bar code. In order for the scanner to communicate with a host system properly, it may need to be programmed. Since each host system is unique, configure the scanner to match the host system requirements. Configure the scanner by entering the program mode and scanning the appropriate bar codes that appear in the ScanSelect Scanner Programming Guide. (To use ScanSet™, refer to the ScanSet documentation for information on how to configure a scanner.) 1. Connect the scanner to the host system (Refer to the Scanner Connections to the Host section in this guide). 2. Enter program mode by scanning the ENTER/EXIT program mode bar code. (The unit will beep three times) 3. Scan the appropriate bar code(s) that appear in the ScanSelect Scanner Programming Guide. (Reveal only one bar code to the scanner each time. With your hand, cover the bar code not to be scanned.) 4. Exit program mode by scanning the ENTER/EXIT program mode bar code again. (The new options will be saved and the scanner is ready for normal operation.)
3
Page 7
Stand Installation With the Metrologic stand (Part #45475), the scanner can be positioned in one of two directions. The two orientation choices are vertical or horizontal. (Refer to Figure 1) To install this stand, use the four 632 x ½ inch machine screws and two #10 panhead wood screws. 1. Drill two holes into the work surface that are the same size and distance as the holes on the stand base. (Refer to Figure 2)
Figure 1
Base of Stand
2. Use the two #10 panhead wood screws to attach the stand to the work surface. Figure 2
3. To fasten the scanner: ! For a horizontal mount, align the four holes on the back of the scanner with the four clearance holes located on the stand marked with an X in Figure 3. ! For a vertical mount, align the four holes on the back of the scanner with the four clearance holes located on the stand marked with a Y in Figure 3.
Figure 3
4. Fasten the scanner to the stand by inserting the four 6-32 x ½ inch screws into the four holes in the scanner’s case.
4
Page 8
Back Plate Installation With the Metrologic back plate (Part #45473), position the scanner in one of two directions. The two orientation choices are vertical or horizontal. (Refer to Figure 4). To use this stand, use the four 6-32 x ½ inch machine screws and four wood screws to attach the unit to the back plate and work surface. The maximum distance the screws should go into the scanner is a ½ inch.
Figure 4
1. Drill four holes into the work surface that correspond with the holes indicated by an XY in Figure 5. 2. To fasten the scanner to the back plate: ! For a horizontal mount, align the four holes on the back of the scanner with the four clearance holes located on the back plate marked with an X in Figure 5. ! For a vertical mount, align the four holes on the back of the scanner with the four clearance holes located on the back plate marked with a Y in Figure 5. 3. Fasten the scanner to the back plate by inserting the four 6-32 x ½ inch screws into the four holes in the scanner’s case. Fasten the scanner and back plate to the work surface.
Figure 5
5
Page 9
Parts of the Scanner
1 Green and Red LEDs
2 Speaker
3 Laser Output Window
4 Mil spec Connector
Figure 6
6
1
Green and Red LEDs
When the green LED is on, this indicates that the unit is receiving power and the laser is on. When the red LED flashes on, the scanner has read a bar code successfully. When the red light turns off, communica-tion to the host is complete.
2
Speaker
The speaker emits a beep when a bar code has been decoded.
3
Laser Output Window
This aperture emits the laser light.
4
Mil spec Connector
The 19-pin male Mil spec connector was designed to connect a communi cation cable from the scanner to a host device. The communication cable may include a power supply or it may be de signed to draw power directly from the host device. The standard TECH 7 has one connector. (When atrium option is installed, a second connector is installed on the unit to connect the MX001 Industrial Control Interface box.)
Page 10
Visual Indicators There is a red and green LED at the top of the scanner. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the scan and scanner. Steady Green When the laser is on, the green LED is also on. This occurs when an object is in the scan field. Steady Green; Red Flash When the scanner successfully reads a bar code, the red LED will flash then beep once. If the red LED does not flash or the scanner does not beep once, then the bar code has not been successfully read. Steady Red and Green After a successful scan, the scanner transmits the data to the host device. When the host is not ready to accept the information, the scanner’s red LED will remain on until the data can be transmitted. Alternating Red and Green This indicates the scanner is in program mode. Steady Red This indicates the scanner is in ScanSet mode. No Red or Green LED There are two reasons why the LEDs will not be illuminated. First, if the scanner is receiving power and the LEDs are not on, then the scanner has remained dormant for a specified time and the laser has turned off. To reactivate the unit, touch the touch plate. Secondly, if the scanner is not receiving power from the host or transformer, then the LEDs will not turn on. Flashing Red This indicates the scanner has experienced a laser subsystem failure. Return the unit for repair at an authorized service center.
7