MS9535 VoyagerBT Wireless Hand-Held Laser Scanner Installation and User's Guide, pages 1 to 10

Pages 1 to 10 of 49: MS9535 VoyagerBT; Manual Date Code

The original document is the PDF (879 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic MI9535 and Metrologic MS9535

Page 1 read from a scan by OCR; it may hold reading errors

@ Metrologic’

METROLOGIC INSTRUMENTS, INC. MS9535 VoyagerBT™ Wireless Hand-Held Laser Scanner

Installation and User’s Guide

3 |

_ 4 a oO

@

4 v

Page 2

This page is a scan with no text; see it in the PDF.

Page 3

LOCATIONS CORPORATE HEADQUARTERS North America

Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683

Customer Service: 1-800-ID-METRO Tel: 856-228-8100 Fax: 856-228-6673 Email: info@metrologic.com Internet: www.metrologic.com

EUROPEAN HEADQUARTERS Germany, Middle East and Africa

Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany

Tel: +49 89 89019 0 Fax: +49 89 89019 200 Email: info@europe.metrologic.com Germany Email: info@de.metrologic.com

Spain

Metrologic Eria lbérica SL Julián Camarillo 29, D-1 Edificio Diapasón 28037 Madrid

Tel: +34 913 272 400 Fax: +34 913 273 829 Email: info@es.metrologic.com

Italy

Metrologic Instruments Italia srl Via Emilia 70 40064 Ozzano dell’Emilia (BO)

Tel: +39 0 51 6511978 Fax: +39 0 51 6521337 Email: info@it.metrologic.com

France

Metrologic Eria France SA 69 Rue de la Belle Etoile ZI Paris Nord II, BP 50057 95947 – ROISSY CDG CEDEX

Tel: +33 (0) 1 48.63.78.78 Fax: +33 (0) 1 48.63.24.94 Email: info@fr.metrologic.com

United Kingdom

Metrologic Instruments UK Limited 58 Tempus Business Centre Kingsclere Road, Basingstoke Hampshire RG21 6XG

Tel: +44 (0) 1256 365900 Fax: +44 (0) 1256 365955 Email: info@uk.metrologic.com

Russia

Metrologic Russia Bolshaya Novodmitrovskaya 14 RU-125015 Moscow, Russia

Tel: +7 095 50 93 485 Email: info@ru.metrologic.com

Singapore

Metrologic Asia (Pte) Ltd No. 8 Kaki Bukit Place 4th Floor Singapore 416186

Tel: 65-6842-7155 Fax: 65-6842-7166 Email: info@sg.metrologic.com

China

Metro (Suzhou) Technologies Co., Ltd. 221 Xing Hai Street Suzhou Industrial Park Suzhou, China 215021

Tel: 86-512-62572511 Fax: 86-512-62571517 Email: info@cn.metrologic.com

Japan

Metrologic Japan Co., Ltd. Matsunoya Building, 6 Floor 3-14-8 Higashiueno Taitou-Ku, Tokyo 110-0015 Japan

Tel: 81-03-3839-8511 Fax: 81-03-3839-8519 Email: info@jp.metrologic.com

Brazil

Metrologic do Brasil Ltda. Rua da Paz 2059 CEP 04713-002 Chácara Santo Antônio São Paulo, SP, Brasil

Tel: 55-11-5182-8226 Fax: 55-11-5182-8315 Email: info@br.metrologic.com

Outside Brazil

Metrologic South America Rua da Paz 2059 CEP 04713-002 Chácara Santo Antônio São Paulo, SP, Brasil

Tel: 55-11-5182-7273 Fax: 55-11-5182-7198 Email: info@sa.metrologic.com

ASIA

SOUTH AMERICA

Copyright © 2003 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.

ii

Page 4

TABLE OF CONTENTS Introduction........................................................................................................... 1 Scanner and Accessories..................................................................................... 2 Quick Start............................................................................................................ 3 RS232 and Light Pen Scanner Installation........................................................... 5 Keyboard Wedge Scanner Installation ................................................................. 6 USB Scanner Installation ..................................................................................... 7 Establish Communication Between Scanner and Cradle ..................................... 8 Charging the Scanner .......................................................................................... 9 Receiver / Charger Cradle.................................................................................. 11 Cradle Parts ....................................................................................................... 12 Scanner Parts..................................................................................................... 13 Audible Indicators............................................................................................... 14 Visual Indicators ................................................................................................. 15 Failure Modes..................................................................................................... 17 Programming Modes .......................................................................................... 18 Upgrading the Flash ROM Firmware .................................................................. 19 Labels................................................................................................................. 20 Maintenance....................................................................................................... 20 Depth of Field ..................................................................................................... 21 IR Activation ....................................................................................................... 22 Connecting to other Bluetooth Devices .............................................................. 23 Troubleshooting Guide ....................................................................................... 25 Design Specifications ......................................................................................... 29 Default Settings .................................................................................................. 30 Cradle and Cable Terminations Cradle Pinout Connections............................................................................. 35 Cable Connector Configurations .................................................................... 36 Limited Warranty ................................................................................................ 38 Notices ............................................................................................................... 39 Patents ............................................................................................................... 41 Index................................................................................................................... 42 iii

Page 5

INTRODUCTION MS9535 VoyagerBT laser bar code scanner is a new member of Metrologic’s Voyager series. While featuring the patented technologies of automatic trigger and CodeGate button, the VoyagerBT has incorporated the latest Bluetooth™ wireless technology. With this technology, it allows the scanner freedom of mobility, up to 10 meters from the cradle. VoyagerBT works hand in hand with its cradle. Before normal scanning, the scanner must establish communications with the cradle by scanning a Bluetooth address bar code. After communications have been established between the scanner and cradle, futures bar code scans will be transmitted from the scanner to the cradle and from the cradle to the host. The cradle of the VoyagerBT also works as a battery charger for the scanner. When resting in the cradle, the scanner can reach a fully charged state in 2.5 hours. When fully charged, the scanner can provide up to 12,000 scans. For power saving, the scanner can be put into a full sleep mode by depressing the CodeGate button for 5 seconds after the laser has shut down. In this mode, the scanner can remain powered for up to 35 hours before the batteries require recharging. To wake-up the scanner, simply depress the CodeGate button, and the scanner will resume normal operation, after an automatic reset. VoyagerBT includes ability to decode Reduced Space Symbology (RSS) bar codes. VoyagerBT offers checkout personnel the ability to scan bulky items without the need for unnecessary heavy lifting by customers or checkout personnel, making for added convenience. It can be used in applications including supermarkets, hypermarkets, shopping clubs, retailers, light warehouse and manufacturing.

1

Page 6

SCANNER AND ACCESSORIES BASIC KIT Part #

Description

MS9535-5

VoyagerBT Scanner

70-79004

MS9535 VoyagerBT Wireless Hand Held Laser Scanner Installation and User’s Guide*

00-02544B

MetroSelect Single-Line Programming Guide*

00-02024A

Bluetooth Programming Addendum

* Available on the Metrologic website - www.metrologic.com OPTIONAL ACCESSORIES Part #

Description Receiver / Charger Cradle

MI9535-514

Receiver / Charger Cradle, Full RS232

MI9535-541

Receiver / Charger Cradle, RS232/Light Pen

MI9535-547

Receiver / Charger Cradle, Keyboard Wedge

MI9535-537

Receiver / Charger Cradle, USB

AC to DC Power Transformer- Regulated 5VDC @ 2A Output 46-46911

Power Supply, China

46-46912

Power Supply, United Kingdom

46-46913

Power Supply, Continental Europe

46-46914

Power Supply, Australia

46-46915

Power Supply, United States Communication Cable

54-54000B-N

RS232 / Light Pen Cable, short strain relief

57-57002A

Keyboard Wedge Cable, short strain relief

52-52828A

USB Cable, short strain relief

Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.

2

Page 7

QUICK START 1.

Connect the 10-pin RJ45 male connector into the 10-pin modular jack on the bottom of the cradle. You will hear a ‘click’ when the connection is made.

2.

Connect the plug of the power supply into the power jack on the bottom of the cradle.

3.

Connect the power supply into an AC outlet. The blue LED on the rear of the cradle will stay on.

p o n 4.

Pick up the scanner and scan the Bluetooth address code on the cradle, you will hear 3 continuous beeps. After 4 seconds, both the blue LEDs of the charger cradle and the scanner flashes, followed by a 3 combination beeps. This means the communication between the cradle and the scanner has been established successfully.

q Bluetooth Address Code* *This is a configuration bar code attached on the cradle. Before the normal scanning, you must establish a communication between the scanner and the receiver. Please go to Page 8 for more details. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV ( Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

3

Page 8

QUICK START (CONTINUED) 5.

Scan a bar code anywhere within 10 meters from the cradle. The scanner will beep once and flash the white LED. The blue LED of the cradle will also flash once, indicating that the bar code has been successfully read and transmitted.

r MS9535 VoyagerBT also provides two modes of operation: 1.

Auto-trigger mode When the scanner is at rest in the cradle, it is in auto-trigger mode. While in this mode, present a bar code in the scanning field and the data is automatically decoded and transmitted.

2.

CodeGate mode When the scanner is removed from the cradle, it is in CodeGate mode. While in this mode, scanned bar code data is only decoded and transmitted when the CodeGate button is pressed. MS9535 is shipped from the factory programmed with default settings. Refer to the MetroSelect Single-Line Programming Guide (MLPN 0002544B) or MetroSet2’s help files for instructions on how to configure the scanner.

4

Page 9

RS232 AND LIGHT PEN SCANNER INSTALLATION 1.

Turn off the host system.

2.

Connect the 10-pin RJ45 male connector into the 10-pin modular jack on the bottom of the cradle. You will hear a ‘click’ when the connection is made.

3.

Connect the plug of the power supply into the power jack on the bottom of the cradle.

4.

Connect the power supply into an AC outlet. The blue LED on the rear of the cradle will stay on.

5.

Connect the 9-pin D-type connector of the RS232 cable to the proper COM port of the host system.

6.

Turn on the host system.

s q p o n r

Right installation does not guarantee that the scanned information will be communicated properly to the host system. The scanner is shipped from the factory programmed with default settings. Please refer to the MetroSelect Programming Guide (MLPN 00-02544B) or MetroSet2’s help files for instructions on changing the scanner’s configuration. In addition, please check that the cradle and host system are using the same communication protocol.

Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV ( Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

5

Page 10

KEYBOARD W EDGE SCANNER INSTALLATION 1.

Turn off the host system.

2.

Connect the 10-pin RJ45 male connector into the 10-pin modular jack on the bottom of the cradle. You will hear a ‘click’ when the connection is made.

3.

Connect the plug of the power supply into the power jack on the bottom of the cradle.

4.

Connect the power supply into an AC outlet. The blue LED on the rear of the cradle will stay on.

5.

Disconnect the keyboard from the PC.

6.

The keyboard wedge cable is terminated with a 5-pin DIN female connector on one end, and a 6-pin mini DIN male on the other. Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other. According to the termination required, connect the appropriate end of the adapter cable to the main cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC.

7.

Connect to the main cable to the keyboard and the keyboard port on the host system.

8.

Power up the host system.

p o q

Optional s &t u n r

Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV ( Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

6