Spec sheet · Metrologic
Metrologic MS951 Spec Sheet
Spec sheet2 pagesPDF 668 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A two-page Metrologic spec sheet (September 1998) for the MS900 Series automatic hand-held laser scanners: the undecoded MS941, the standard decode MS951 and the high density MS961. It describes the automatic infrared trigger and hands-free use, and lists operational, mechanical, electrical and environmental specifications.
- What it is
- Automatic hand-held laser scanner that also works hands-free in a fixed stand; the MS951 is the standard decode model p. 1
- Interfaces
- MS951/961: RS232, Light Pen Emulation, OCIA, IBM 46XX, PC Keyboard Wedge, Stand-Alone Keyboard p. 2
- Activation
- Infrared sensor for fully automatic activation; programmable short-range and long-range activation p. 1
- Laser and scan
- Visible laser diode 675 nm; single scan line; 36 scan lines per second p. 2
- Decoding
- MS951/961: autodiscriminates all standard bar codes; up to 80 data characters p. 2
- Power
- 5 VDC; MS951/961: 0.8 w p. 2
- Size and weight
- 205 mm x 63 mm x 24 mm (8.0 in x 2.5 in x 0.94 in); MS951/961: 177 g (6.20 oz) p. 2
- Coiled cable
- Collapsed 146.3 cm (4.8 ft); extended 243.8 cm (8 ft) p. 2
- Indicators
- MS951/961: 3 tones or no beep; red LED = laser on, ready to scan; green LED = good read p. 2
- Print contrast
- 35% minimum reflectance difference p. 2
- Drops
- Designed to withstand 1.5 m (5 ft) drops p. 2
- Environment
- 5% to 95% relative humidity, non-condensing; up to 450 footcandles; sealed against airborne particulates p. 2
What this sheet walks you through
- Using the scanner hands-free in its fixed stand p. 1
- Short-range and long-range laser activation p. 1
- Depth of field charts by bar code minimum element p. 2
Good to know
- Depth of field depends on the bar code. p. 2
Questions this sheet answers
What is the difference between the MS941, MS951 and MS961?
The MS941 is undecoded, the MS951 is the standard decode model, and the MS961 is decoded with high density code reading. p. 1
What interfaces does the Metrologic MS951 support?
RS232, light pen emulation, OCIA, IBM 46XX, PC keyboard wedge and stand-alone keyboard. p. 2
Does the MS951 need a trigger button?
No. A patented infrared sensor activates it automatically: the operator waves the scanner across a bar code, or presents items to it in its stand. p. 1
How much does the MS951 weigh?
177 g (6.20 oz). p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
MS900 Series Features
- Patented automatic trigger
- Combination hand-held/fixed projection
- Short-range and long-range activation
- Superior ergonomics
- Rugged and reliable
- Easy to program
- Low cost
Metrologic’s MS900 Series hand-
Automatic Laser Scanner
held laser scanners provide unsurpassed versatility and adaptability. In these innovative scanners, Metrologic has engineered the best of two worlds: the increased depth of field, accuracy, and high performance of a laser with the durable construction and low cost of a CCD. The MS900 also has a unique patented infrared sensor and control scheme that provides fully automatic activation and operation for complete hands-free scanning. The MS900 can be used either as a hand-held scanner or fixed scanner because of its unique design. An operator can simply “wave” the scanner in a natural position across a bar code and the MS900 will scan automatically. This automatic operation increases worker efficien-
cy and productivity by allowing faster throughput. This added operator comfort reduces the risk of repetitive strain injury. The versatile MS900 can operate as a “handsfree” scanner when placed in its flexible, fixed stand. An operator can present bar coded items to the MS900 for automatic scanning. Special patents also make it possible to program the scanner for short-range and longrange laser activation in either the hand-held or hands-free mode. The MS900 series consists of three models: the undecoded MS941; the standard decode MS951; and the MS961 decoded with high density code reading capabilities.
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
MS900 Series O P E R AT I O N A L Light Source Depth of Field* Scan Speed Scan Pattern Minimum Bar Width Long Range Activation Short Range Activation Decode Capability System Interfaces Print Contrast Number Characters Read
Depth of Field Visible Laser Diode 675 nm + 5 nm 0 mm - 200 mm (0” - 8”) 36 scan lines per second Single scan line MS961: 0.13 mm (5.0 mil) MS951: 0.19 mm (7.5 mil) MS941: 0.19 mm (7.5 mil) minimum: 0 mm - 200 mm (0” - 8”); typical: 0 mm - 280 mm (0” - 11”) minimum: 0 mm - 75 mm (0” - 3”); typical: 0 mm - 125 mm (0” - 5”) MS951/961: Autodiscriminates all standard bar codes; MS941: Non-decode only MS951/961: RS232, Light Pen Emulation, OCIA, IBM 46XX, PC Keyboard Wedge, Stand-Alone Keyboard MS941: Decoder dependent 35% minimum reflectance difference Up to 80 data characters
MS951/941
Bar Code Minimum Element
0.19 mm (7.5 mil) 0.26 mm (10.4 mil) 0.33 mm (13 mil) 0.53 mm (21 mil)
(Maximum number will vary based on symbology and density)
Roll, Pitch, Yaw Beeper Operation
42°, 68°, 52° MS951/961: 3 tones or no beep MS941: Decoder dependent MS951/961: Red = laser on, ready to scan; Green = good read MS941: decoder dependent
Indicators (LED)0101 mm (4”)0101 mm (4”)202 mm (8”)
MECHANICAL Dimensions Weight
205 mm x 63 mm x 24 mm (8.0” x 2.5” x 0.94”) MS951/961: 177 g (6.20 oz) MS941: 156 g (5.45 oz) Collapsed: 146.3 cm (4.8’); Extended: 243.8 cm (8’)
Cable (coiled)
MS961
ELECTRICAL Input Voltage Power
5 VDC + 0.25 V MS951/961: 0.8 w MS941: 0.5 w MS951/961: 165 mA typical @ 5 VDC MS941: 100 mA typical @ 5 VDC MS951/961: 65 mA typical @ 5 VDC MS941: 30 mA typical @ 5 VDC Class 2; 5 VDC @ 300 mA CDRH: Class II; EN60825-1: 1994/A11: 1996 Class I FCC Class A, CISPR 22 Class A
Operating Current Standby Current DC Transformers Laser Class EMC
Bar Code Minimum Element
0.13 mm (5 mil) 0.17 mm (6.5 mil) 0.26 mm (10.4 mil) 0.33 mm (13 mil)
E N V I R O N M E N TA L Operating Temperature Storage Temperature Humidity Light Levels Shock Contaminants Ventilation
0°C to 35°C (32°F to 95°F) -40°C to 60°C (-40°F to 140°F) 5% to 95% relative humidity, non-condensing Up to 450 footcandles Designed to withstand 1.5 m (5’) drops Sealed to resist airborne particulate contaminants None required
*Bar code dependent. Specifications subject to change without notice. Printed U.S.A., September 1998
USAEuropeSouth AmericaBrazilAsia
Metrologic Instruments, Inc. Tel. 1-800-ID-METRO Fax 1-609-228-6673 info@metrologic.com
Metrologic Instruments GmbH Tel. 49-89-89019-0 Fax 49-89-89019-200 metrologic@europe.metrologic.com
Metrologic Instruments Tel. 55-11-5505-6568 Fax 55-11-5505-1681 info@sa.metrologic.com
Metrologic do Brasil Ltda Tel. 55-11-5505-2396 Fax 55-11-5507-2301 metrolog@br.metrologic.com
Metrologic Asia (Pte) Ltd Tel. 65-842-7155 Fax 65-842-7166 ant888@cyberway.com.sg
Metrologic Instruments, Inc. | 90 Coles Rd. | Blackwood, New Jersey 08012 Telephone 609-228-8100 or 1-800-ID-METRO