Page 37
DEFAULT SETTINGS (CONT.) PARAMETER
DEFAULT
CLSI Editing
OCIA
IBM 46XX
9
9
KEYBOARD RS-232* PARALLEL WEDGE
9
9 9
French PC Term Transmit AIM ID Characters
9
9
Nixdorf ID
9
9
UPC Prefix
9
9
UPC Suffix
9
9
STX Prefix
9
9
ETX Suffix
9
9
Carriage Return
*
9
9
Line Feed
*
9
9
Tab Prefix
9
9
Tab Suffix
9
9
"DE" Disable Command "FL" Laser Enable Command DTR Handshaking Support RTS/CTS Handshaking Character RTS/CTS Message RTS/CTS XON/XOFF Handshaking
9 9 9 9 9
*
9 9 9
ACK/NAK 5 Retries on ACK/NAK Time-out Keyboard Country Type
LIGHT PEN
9 USA
9
33
Page 38
DEFAULT SETTINGS (CONT.) OCIA
IBM 46XX
KEYBOARD RS-232* PARALLEL WEDGE
PARAMETER
DEFAULT
Keyboard Type
AT
9 9 9
Inter Scan Code Delay
800 µsec
9
Transmit F0H Break Code (AT and PS/2 keyboards)
*
9
Caps Lock Alt Mode
LIGHT PEN
Special Software is required for the following: Two Digit Supplements
9
9
9
9
9
Five Digit Supplements
9
9
9
9
9
Bookland
9
9
9
9
9
977 (2 digit) Supplemental Requirement
9
9
9
9
9
Supplements are not Required
*
9
9
9
9
9
Two Digit Redundancy
*
9
9
9
9
9
Five Digit Redundancy
9
9
9
9
9
200 msec to Find Supplement
9
9
9
9
9
9
9
9
9
9
Code 128 Coupon Extended Code
9
9
9
9
Code 128 ]C1 Extended Code Format
9
9
9
9
100 msec to Find Supplement
34
*
Page 39
SCANNER PINOUT CONNECTIONS Version “1” Pin Assignments for RS-232, OCIA and Light Pen Emulation The version “1” scanner head cable is terminated with a male 25-pin D-type connector. Connecting the scanner to the host device may require a communication cable. The communication cable may include a connection for a transformer or it may be designed to draw power directly from the host device. This can be ordered when the scanner is purchased. The version “1” scanner is designed to be used for RS-232, OCIA or Light Pen Emulation communication. The following is a list of the pin assignments. The pin numbers are impressed on the head cable’s connector.
PIN
FUNCTION
1
AC Shield Ground
2
RS-232 Receive Input
3
RS-232 Transmit Output
4
CTS Input
5
RTS Output
6
Reserved
7
Signal Ground
8 - 12
Reserved
13
Earth Ground
14
Power Ground 1
15
Light Pen Source
16
Light Pen Data
17
OCIA Clock In Return
18
OCIA Clock In
19
Power (11 - 30 volts) DC
20
DTR Input
21
OCIA Clock Out
22
OCIA Clock Out Return
23
OCIA RDATA
24
OCIA RDATA Return
25
Power Ground 2
35
Page 40
SCANNER PINOUT CONNECTIONS Version “2” Pin Assignments for Parallel Communication The version “2” scanner head cable is terminated with a male 25-pin D-type connector. Connecting the scanner to the host device may require a communication cable. The communication cable may include a connection for a transformer or it may be designed to draw power directly from the host device. This can be ordered when the scanner is purchased. The version “2” scanner is designed to be used for Parallel communication. The following is a list of the pin assignments. The pin numbers are impressed on the head cable’s connector.
PIN
36
FUNCTION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
AC Shield Ground RS-232 Receive Input RS-232 Transmit Output CTS Input RTS Output Reserved Signal Ground Reserved Edit Check EOT Data Ready Adaptor Ready Earth Ground Power Ground 1 Light Pen Source Light Pen Data Data 1 Data 2 Power (11 - 30 volts) DC DTR Input Data 3 Data 4
23 24 25
Data 5 Data 6 Power Ground 2
Page 41
SCANNER PINOUT CONNECTIONS Version “11” Pin Assignments for RS-485 The version “11” scanner head cable is terminated with a male 25-pin D-type connector. Connecting the scanner to the host device may require a communication cable. The communication cable may include a connection for a transformer or it may be designed to draw power directly from the host device. This can be ordered when the scanner is purchased. The version “11” scanner is designed to be used primarily with IBM 46XX series of electronic cash registers. It can also be configured to communicate using the full RS-232 and OCIA protocol. The following is a list of the pin assignments. The pin numbers are impressed on the head cable’s connector.
PIN 1 2 3 4 5 6 7 8 - 12 13 14 15 16 17 18 19 20 21 22 23 24 25
FUNCTION AC Shield Ground RS-232 Receive Input RS-232 Transmit Output CTS Input RTS Output Reserved Signal Ground Reserved Earth Ground Power Ground 1 468X -B 468X +A OCIA Clock In Return OCIA Clock In Power (11 - 30 volts) DC DTR Input OCIA Clock Out OCIA Clock Out Return OCIA RDATA OCIA RDATA Return Power Ground 2
37
Page 42
SCANNER PINOUT CONNECTIONS Version “17” Pin Assignments for Keyboard Wedge, RS-232 and Light Pen Emulation The version “17” scanner head cable is terminated with a male 25-pin D-type connector. Connecting the scanner to a PC, requires a communication cable and a transformer. Connecting the communication cable to a PC, may require an adapter cable. The version “17” scanner is designed to be used as a keyboard wedge. With the appropriate communication cable, the scanner will also provide an RS-232 or light pen emulation interface. When configuring the scanner for an interface it is necessary to set the correct parameters for that interface. For further information on configuring interfaces, refer to the ScanSelect Scanner Programming Guide or ScanSet Scanner Configuration Guide. The following is a list of the pin assignments. The pin numbers are impressed on the head cable’s connector.
PIN
38
FUNCTION
1 2 3 4 5 6 7 8 - 10 11 12 13 14 15 16 17 18 19 20 21
AC Shield Ground RS-232 Receive Input RS-232 Transmit Output CTS Input RTS Output Reserved Signal Ground Reserved PC +5 Volts DC Ground Earth Ground Power Ground 1 Light Pen Source Light Pen Data PC Data PC Clock Power (11 - 30 volts) DC DTR Input Keyboard Clock
22 23 - 24 25
Keyboard Data Reserved Power Ground 2
Page 43
Limited Warranty The MS860 and MS863 scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS860 and MS863 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS860 and MS863 scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and local laws, regulations and ordinances pertaining to their production and labeling. This warranty is limited to repair, replacement of Product or refund of Product price at the sole discretion of Metrologic. Faulty equipment must be returned to the Metrologic facility in Blackwood, New Jersey, U.S.A. or Puchheim, Germany. To do this, contact Metrologic’s Customer Service/Repair Department to obtain a Returned Material Authorization (RMA) number. In the event that it is determined the equipment failure is covered under this warranty, Metrologic shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit and return such repaired or replaced Product without charge for service or return freight, whether distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase price. This limited warranty does not extend to any Product which, in the sole judgement of Metrologic, has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage due to use or misuse produced from integration of the Product into any mechanical, electrical or computer system. The warranty is void if the case of Product is opened by anyone other than Metrologic’s repair department or authorized repair centers. THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES, INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY. IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN. Corporate Headquarters Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683 Germany Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany
Customer Service: 1-800-ID-METRO Tel: 856-228-8100 Fax: 856-228-6673 Email: info@metrologic.com Website: www.metrologic.com Tel: 49-89-89019-0 Fax: 49-89-89019-200 Email: info@europe.metrologic.com
39
Page 44
NOTICES Notice This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Any unauthorized changes or modifications to this equipment could void the users authority to operate this device. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Notice This Class A digital apparatus complies with Canadian ICES-003. Remarque Cet appareil numérique de la classe A, conformé a la norme NMB-003 du Canada. Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device. Doing so could result in hazardous laser light exposure. The use of optical instruments with the laser equipment will increase eye hazard. Atención La modificación de los procedimientos, o la utilización de controles o ajustes distintos de los especificados aquí, pueden provocar una luz de láser peligrosa. Bajo ninguna circunstancia el usuario deberá realizar el mantenimiento del láser del escáner. Ni intentar mirar al haz del láser incluso cuando este no esté operativo. Tampoco deberá abrir el escáner para examinar el aparato. El hacerlo puede conllevar una exposición peligrosa a la luz de láser. El uso de instrumentos ópticos con el equipo láser puede incrementar el riesgo para la vista. Attention L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de graves irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-même le scanner ou le laser. Ne regardez jamais directement le rayon laser, même si vous croyez que le scanner est inactif. N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez à une rayonnement laser qú êst hazardous. L'emploi d'appareils optiques avec cet équipement laser augmente le risque d'endommagement de la vision. Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, daß der Scanner nicht aktiv ist. Öffnen Sie niemals den Scanner, um in das Gerät hineinzusehen. Wenn Sie dies tun, können Sie sich einer gefährlichen Laserstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser Laserausrüstung erhöht das Risiko einer Sehschädigung.
40
Page 45
NOTICES (CONT.) Attenzione L’utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel presente Manuale può provocare delle esposizioni a raggi laser rischiose. Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser. Non guardate mai il raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l’apparecchio. Facendolo potete esporVi ad una esposizione laser rischiosa. L’uso di apparecchi ottici, equipaggiati con raggi laser, aumenta il rischio di danni alla vista. European Standard Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Funkstöreigenschaften nach EN 55022:1998 Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen; in diesem fall kann vom Betrieber verlangt werden, angemessene Maßnahmen durchführen.
Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere all’utilizzatore opportune misure.
Attention Ce produit est de classe “A”. Dans un environnement domestique, ce produit peut être la cause d’interférences radio. Dans ce cas l’utiliseteur peut être amené à predre les mesures adéquates.