For the Metrologic MS860

Page 10

VERSION 11 IBM 46XX SCANNER Output Format: IBM RS-485 serial input/output for the 4680 and 4690 (46XX) point-of-sale terminals The Version 11 46XX interface can be used in several different ways. Both the 46XX terminal and the scanner must be configured to match each other. Warning: Power to the scanner and 46XX terminal should be turned off before making physical connection. The 4680 and 4690 series terminals have different types of physical ports for connecting bar code scanners. Scanner ports include Port 5B, Port 17, and Port 9? (? = A, B, C, or E). A Port 9 type connector is present on all versions of the 46XX families of terminals. That is one reason why it is the normal point of connection for Metrologic scanners. Another reason is that there is enough 12 volt power available to operate many Metrologic scanners. If your terminal configuration requires the use of a different physical port for connecting bar code scanners, contact Metrologic to get particular adapter cable information. All devices use a common communications bus inside the 46XX terminal, despite what port that is in use for the physical connection. Each device has a different address that it uses when it communicates. The terminal must be configured to look for a device at a logical address. The IBM 1520 mode/address was selected as a default because it was the first IBM 46XX family scanner to support UPC/EAN, Code 39 and Interleaved 2 of 5 (I 2 of 5). The Version 11 scanner formats Codabar, Code 128, and Code 93 using the Code 39 function code designation supported by the IBM device driver for this scanner type. Other emulation modes currently available are the IBM 3687-2 Port 17 fixed scanner and the Port 9B IBM 4500 CCD hand-held bar code reader. The use one of these other emulation modes may be needed depending on which operating system (4680.OS, 4690.OS, POS/DOS or DOS/RIPPS) is in use at your site. Note: The IBM 4683 and IBM 4684 terminals have a good proven track record of supplying power to Metrologic scanners. The IBM 4693 and IBM 4694 terminals may be restricted from supplying power to certain scanner models. Specifically, Metrologic currently recommends using an external power supply for the scanner when connecting to an IBM 4694. Metrologic has no recommendations at this time for IBM 4693 terminals.

6

Page 11

CONFIGURING THE MS860-11/MS863-11 SCANNER Located in the Version 11 scanner are two computer boards. One computer board is for decoding and the other for 46XX IO processing. The decode board is configured using ScanSet or ScanSelect while the IO board is configured with an internal DIP Switch bank. For UPC/EAN scanning, the decode board should be set as follows: Enable IBM 4680 Communication Enable UPC/EAN Beep after Transmit Enable Communication Timeouts Transmit UPC-A Check Digit Transmit UPC-E Check Digit These settings configure the decode board to beep after transmitting the data to the terminal device driver. If the data does not clear the communications buffer within two seconds, it is discarded without giving the operator a good scan indication. This accommodates newer versions of the IBM device drivers that enable/disable scanning in many different situations. The default setting of the interface board is to emulate the IBM 1520 hand scanner that supports UPC/EAN and alphanumeric code types. The following is a list of switch settings for the internal interface board that handles the 46XX SIOC communications. There are eight DIP switches on the board that are both software and hardware switches. Switch 1

Switch 2

Emulation Mode

OFF

OFF

Port 5B, IBM 1520 Model 2 Laser Scanner (default setting)

OFF

ON

Port 9B, CCD (IBM 4500/Opticon)

ON

OFF

Port 17, IBM 4014 Adapter for 3687-2 to 468X

ON

ON

Reserved

Switch 3

Reserved (Should be OFF)

Switches 4, 5, 6, and 7

Must be ON

Switch 8

Should be OFF (Reserved)

7

Page 12

CONFIGURING THE IBM 46XX The 4683 and 4693 terminals are configured on the store controller. The 4684 and 4694 terminals are typically configured on the individual terminals. Follow the appropriate guide for your type of equipment. IBM 4683 and 4693 Terminals Driven by a 46XX Store Controller Running 4680.OS or 4690.OS Access the terminal configuration menu on the store controller. If not already selected, select an IBM 1520 laser hand scanner (4680.OS Port 5B), an IBM 4500 hand-held bar code reader (CCD, 4680.OS Port 9B), or an IBM 3687-2 fixed scanner (4680.OS Port 17) that matches the configuration of your scanner. Regarding the 4690.OS, at the time of this printing, Metrologic does not know exactly which terminal port configuration screen is used for selecting scanners. It should be listed under the Port 9A, 9B, 9C, or 9E sections. The 4693 terminal has a Port 5B that was originally used for the IBM 1520 scanner. While IBM has withdrawn this product, it was not clear how terminal configuration and device driver support would be provided for the installed base of users. Save the configuration and activate it for the desired terminals. Download the configuration to the terminal(s) per standard procedures.

IBM 4684 and 4694 Systems Initialize the RIPPS drivers for a hand scanner if hand scanner emulation was selected. Initialize the RIPPS drivers for a “POS scanner” if the 3687-2 scanner has been selected.

8

Page 13

VERSION 17 KEYBOARD WEDGE SCANNER The MS860/MS863 scanner (version 17) provides keyboard emulation by converting the scanned bar code data to the PC keyboard scan code equivalent. The following are the supported keyboard and country types: PC Type • • •

AT (includes IBM PS/2 and compatible models 50, 55, 60, 80) XT PS/2 (includes IBM PC and compatible models 30, 70, 8556)

Keyboard Country Type • • • •

USA France Italy United Kingdom

• • • •

Germany Spain Belguim Swiss

With the appropriate communication cable, the scanner will also provide an RS-232 or light pen emulation interface. When configuring the scanner for one interface versus another, change all necessary parameters for that particular interface. For instance, when configuring the scanner for keyboard wedge emulation, recall defaults, select the PC type, keyboard country type and intercharacter delay. For further information, refer to the ScanSelect Scanner Programming Guide or ScanSet Scanner Configuration Guide.

9

Page 14

CONNECTION OF A MS860-17 SCANNER TO A PC 1.

If the PC is on, exit your application and turn the PC off.

2.

Disconnect the keyboard from the PC. Plug the Keyboard Wedge cable to the PC and the keyboard. Use the adapter cable if necessary.

3.

Connect the 25-pin D-type connector on the scanner’s head cable to the Keyboard Wedge cable.

4.

Check the AC input requirements of the transformer to make sure the voltage matches the AC outlet. A socket outlet should installed near the equipment and be easily accessible.

5.

Plug the transformer into the side of the female D-type connector located on the communication cable. Plug the transformer into the AC outlet to supply power to the scanner.

6.

Turn the PC on.

7.

When the scanner first receives power, the LEDs will flash and the scanner will beep once. After the scanner performs this start up sequence, the green LED will remain on for a specified time indicating the laser is on.

Figure 1 Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

10

Page 15

OPTIONAL IN-COUNTER MOUNTING OPTIONS FOR THE MS860 Metrologic has designed three plates to accommodate in-counter installation of the MS860. Included automatically with the purchase of the MS860 is Metrologic part #45-45471, Installation Plate. The universal and replacement plates are available for an additional charge. Contact the distributor, dealer or Metrologic customer service representative to order one of these plates. Metrologic Part Number mlpn 45-45471, Installation Plate: This plate is designed for use in counters with no previous cutouts. No routing is necessary for a flush fit as the stainless steel top is only .60mm (.024") thick. The cut out measurements are 180.34 mm (7.1") L x 175.26 mm (6.9”) W. The final cut out must not be greater than 1.5mm (1/16") or less than the exact measurement. Metrologic Part Number mlpn 45-45474, Universal Plate: This plate is designed to fit into an existing cut out up to 292.1 mm (11.5") L x 508 mm (20") W. Metrologic Part Number mlpn 45-45470, Replacement Plate: This plate is designed to fit into a cut out that previously contained an MS260 or MS362 scanner. This plate fits into the existing 293.62 mm (11.56") L x 245.36 mm (9.66") W.

11

Page 16

VERTICAL STAND KIT Vertical Stand Kit, MLPN 45-45472 includes: a. b. c.

Vertical Stand #6-32 x 3/8” Phillips Head Screw #8 x 1.00” Round Head Wood Screw

[ MLPN 45-45472 ] [ MLPN 18-18317 ] [ MLPN 18-18057 ]

Qty. 1 Qty. 2 Qty. 3

Installation Orientation Note: The arrow on the top of the scanner indicates the direction that items must be presented to the scanner.

1.

Drill four #39 pilot holes into the counter top (See Figure 2).

2.

Screw the stand to the counter top with the four #8 wood screws provided.

3.

Secure the unit to the stand using the four #6-32 x 3/8” screws provided (See Figure 4).

Figure 2

Figure 3

Figure 4

12

Page 17

SCANNER PARTS n Touch Plate When a specified time has elapsed without any scanning, the unit will enter a “standby” mode. Touching the touch plate arrow on the top cover will reactivate the scanner.

o Red LED When the red LED flashes ON, the scanner has read a bar code successfully. When the red light turns OFF, communication to the host is complete.

p Green LED When the green LED is ON, this indicates the unit is receiving power and the laser is ON.

q Output Window This aperture emits laser light.

r Head Cable This cable can be connected directly to the host device or to a communication cable.

Figure 5: MS860 & MS863 Scanner Parts s Stainless Steel Top Plate (On the MS860 only.)

t Dark Grey ABS Top Plate (On the MS863 only.) 13

Page 18

The MS860 TOUCH PLATE The MS860 will enter “standby” when it remains dormant for a time. When the scanner’s computer is on “standby," touching the touch plate will “wake up” the scanner and activate the laser. When the green LED comes on, the scanner is powering up for full operation. After approximately three seconds, the scanner will be ready to operate. The default touch plate timeout is ten minutes. However, this can be changed through ScanSet or by scanning a bar code in Section C of the ScanSelect Programming Guide. The available times are two minutes, thirty minutes or no timeout. Plaque de palpeur Le scanner passe en mode 'Stand-by' quand il n'est pas utilisé pendant une certaine période. Si le calculateur du scanner se trouve en mode 'Stand-by', le contacte de la plaque de palpeur "réveille" le scanner et active le laser. L'allumage de la diode verte indique que le scanner se met en service en attente d'utilisation. Au bout d'environ 3 secondes, le scanner est prêt à servir. La temporisation standard de plaque de palpeur est de 10 minutes. Ceci peut toutefois être modifié avec ScanSet ou par lecture d'un code barres au chapitre C du manuel de programmation ScanSelect. Les durées disponibles sont deux minutes, trente minutes ou même aucune temporisation. Sensorplatte Der Scanner tritt in den 'Stand-by'-Modus ein, wenn er für einen bestimmten Zeitraum untätig geblieben ist. Befindet sich der Rechner des Scanners im 'Stand-by'-Modus, "weckt" die Berührung der Sensorplatte den Scanner und aktiviert den Laser. Das Aufleuchten der grünen Leuchtdiode zeigt an, daß der Scanner sich für volle Betriebsbereitschaft einschaltet. Nach etwa drei Sekunden ist der Scanner betriebsbereit. Der Standard-Sensorfeld-Timeout liegt bei zehn Minuten. Dies kann jedoch geändert werden durch ScanSet oder Einlesen eines Barcodes in Abschnitt C des ScanSelect Programmierhandbuchs. Die verfügbaren Zeiträume sind zwei Minuten, dreißig Minuten oder gar kein Timeout. Piastra sensore Se lo scanner è rimasto disattivato per un determinato periodo esso passa in modalità 'stand-by'. Quando il calcolatore dello scanner si trova in modalità 'stand-by', occorre toccare la piastra sensore per "svegliare" lo scanner ed attivare il laser. L’accensione del diodo luminoso verde indica che lo scanner si accende per diventare completamente pronto. Dopo circa tre secondi lo scanner ha raggiunto la condizione "pronto". Il timeout standard della zona sensore è regolato su dieci minuti. Questo valore può, però, essere modificato con lo ScanSet oppure con la lettura di un codice a barre, come descritto nella sezione C del Manuale di programmazione ScanSelect. Gli intervalli possibili sono due minuti, trenta minuti oppure nessun timeout. 14