Page 41

DEFAULT SETTINGS (CONTINUED) Parameter

Default

Bookland 977 (2 digit) Supplemental Requirement

OCIA

RS-232

Light Pen

IBM 46XX

KBW

USB a a a a a a

Supplements are not Required

* a a a a a a

Two Digit Redundancy

* a a a a a a a a a a a a a a a a a a a a as code 39 a a a a a a a a a a a a

Suffix Characters a a a

Prefixes for individual Code Types a a a a a a a a a

Five Digit Redundancy 100 msec to Find Supplement Programmable in 100 msec steps (MAX 800 msec)

*

Coupon Code 128

Programmable Code Lengths

7 avail.

Programmable Prefix Characters

10 avail.

a

Editing Inter Scan-Code Delay Programmable (100 µsec steps)

a a a

800 µsec

Function/Control Key Support Minimum Element Width Programmable in 5.6 µsec steps a

1 msec

Depth of Field Variable Depth of Field

* a a a a a a

Normal Depth of Field

* a a a a a a a a a a a a a a a a a a a a a a a a

Extended Depth of Field Long Depth of Field Ultra Close Depth of Field

*

37

Page 42

DEFAULT SETTINGS (CONTINUED) Default settings for “Aux” interface The secondary scanner and the MS7320 always communicate via RS232. Data is relayed to the host via various primary interfaces. Parameter

Default

OCIA

RS-232

Light Pen

IBM 46XX

KBW

USB

Aux Baud Rate

38400 a a a a a a

Aux parity space a a a a a a

Aux data bits

7 a a a a a a

Aux stop bits

2 a a a a a a

Aux character RTS

* a a a a a a a a a a a a

Aux message RTS

Aux Ack/Nak

* a a a a a a

Aux Xon/Xoff

* a a a a a a

Aux D/E commands a a a a a a

Aux M/O commands a a a a a a

Aux F/L commands a a a a a a

Aux Intercharacter Delay

1 msec a a a a a a

Aux Port Data Format

None (Disabled)

a a a a a a

38

Page 43

MS7220 STANDS Vertical Stand Kit [ MLPN 46-46405 ] See page 40 for installation instructions.

Kit Includes: a. #8 x 1 round head wood screw b. M3 x .5 x 6mm pan head screw c. Vertical base cover d. Cable door

[ MLPN 18-18057 ] [ MLPN 18-18670 ] [ MLPN 36-00363 ] [ MLPN 18-18057 ]

Qty. 4 Qty. 3 Qty. 1 Qty. 2

Tools required for installation: • Flat head screw driver • Phillips head screw driver • ¼”-20 wrench • Drill with #39 drill bit (Needed for hard mount installation only)

Optional Flex Stand Kit [ MLPN 46-46404 ] See 41 for installation instructions.

Kit Includes: a. Long coupler b. Bearing plate c. Bellows d. Flex pole e. ¼ -20 x 3/8 pan head screw

[ MLPN 36-00324 ] [ MLPN 36-00501 ] [ MLPN 36-36615 ] [ MLPN 36-00351 ] [ MLPN 18-18602 ]

Qty. 1 Qty. 1 Qty. 1 Qty. 1 Qty. 1

Tools required for installation: • Flat head screw driver • Phillips head screw driver • ¼”-20 wrench • Drill with #39 drill bit (Needed for hard mount installation only) 39

Page 44

MS7220 STANDS Vertical Stand Installation [ MLPN 46-46405 ] Remove the three screws securing the cable cover to the unit and slide it up and off the scanner. Disconnect the cable and slide the horizontal stand up and off the unit.

Disassemble the horizontal stand and remove the horizontal cover plate.

Mounting the MS7220: Peel off the base plate’s tape backing and affix it to the countertop or drill four #39 pilot holes and secure the base plate to the countertop with the four #8 wood screws provided.

40

Replace the horizontal base cover with the vertical base cover [ 36-00363 ] then reassemble.

Move the side cover from the vertical to the horizontal position on the unit.

Slide the vertical stand onto the unit.

Reattach the cable and secure the cable cover with the three M3 screws.

Page 45

MS7220 STANDS Optional Flexible Stand Installation [ MLPN 46-46404 ] Remove the three screws securing the cable cover to the unit and slide it up and off the scanner. Disconnect the cable and slide the horizontal stand up and off the unit.

Disassemble the horizontal stand. Remove the lock nut and the short coupler. They will not be used on the flex stand.

Mounting the MS7220: Peel off the base plate’s tape backing and affix it to the countertop or drill four #39 pilot holes and secure the base plate to the countertop with the four #8 wood screws provided.

Slide the bearing plate over the stud on the base plate then attach the flex pole.

Slide the bellows over the flex pole and cable. Position the long coupler over the top of the bellows. Secure the long coupler in place with the ¼-20 pan head screw provided then position the foam insert over the screw head.

Slide the flex stand on the unit.

Reconnect the cable and secure the cable cover with the three M3 screws.

41

Page 46

SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS7220 scanner interfaces terminate to 10-pin modular jacks located on the back of the unit. The serial # label indicates the interface enabled when the scanner is shipped from the factory.

Figure 15: EAS Scanner Interface Ports

MS7220-13 OCIA Pin 1 2 3 4 5 6 7 8 9 10

Function Ground NC NC RDATA RDATA Return Clock in Clock out Clock in Return/ Clock out Rtrn +5VDC Shield Ground

Continued next page

42

MS7220-13 IBM 46xx Pin 1 2 3 4 5 6 7

Function Ground RS232 Transmit Output RS232 Receive Input RTS Output CTS Input DTR IBM B- (D-)

8

IBM A+ (D+)

9 10

+5V IN NC

Page 47

SCANNER AND CABLE TERMINATIONS (CONTINUED)

Figure 16: Scanner Interface Ports

MS7220-37 Keyboard Wedge, Stand Alone Keyboard or USB Pin Function 1 Ground 2 USB D3 USB D+ 4 PC Data 5 PC Clock 6 KB Clock 7 PC +5V, V-USB 8 KB Data 9 +5VDC 10 Shield Ground

MS7220-37 RS-232 or Light Pen Pin 1 2 3 4 5 6 7 8 9 10

Function Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input DTR Input/LTPN Source Reserved LTPN Data +5VDC Shield Ground

MS7220-13/-37 Auxilary Port RS232 IN Only Pin Function 1 Ground 2 RS-232 Receive Input 3 RS-232 Transmit Output 4 RTS in 5 CTS out 6-10 NC

43

Page 48

SCANNER AND CABLE TERMINATIONS (CONTINUED) Cable Connector Configurations (Host End) PowerLink Cable MLPN 54-54xxx* Pin 1 2 3 4 5 6 7 8 9

Function Shield Ground RS-232 Transmit Output RS-232 Receive Input DTR Input Power/Signal Ground Reserved CTS Input RTS Output +5VDC xxx* specifies connection to the host

USB PowerLink Cable (MLPN 54-54165, Type A) Pin 1 2 3 4

Function N/C DD+ Ground

5

6

1

9-Pin D-Type Conn.

4 1 USB Type A (Top) Locking Type A (Bottom)

4 1

PowerLink, RS232 AUX Cable MLPN 54-54667 Pin 1 2 3 4 5 6-10

9

Function Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input N/C

1

10

10-pin Modular Plug

Stand Alone Keyboard Cable MLPN 54-54020 Pin 1 2 3 4 5 6

44

Function PC Data NC Power Ground +5VDC PC Power to KB PC Clock NC

1

2 4

3 6 5

6-Pin Male Mini-DIN Conn.

Page 49

SCANNER AND CABLE TERMINATIONS (CONTINUED) Cable Connector Configuration The PowerLink cable is terminated with a 5-pin DIN female connector on one end, and a 6-pin mini DIN male on the other. 4

2

1

5

2

3

4

1 3 6 5

PowerLink Cable 5-Pin DIN, Female

6-Pin DIN, Male

Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other. 5 3

2

4

1

1

2

3

4 5 6

5-Pin Din, Male

Adapter Cable

6-pin Mini Din, Female

According to the termination required, connect the appropriate end of the adapter cable to the PowerLink cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC. The pin assignments are as follows: PowerLink Cable Pin 1 2 3 4 5

5-pin Female DIN Function Keyboard Clock Keyboard Data No Connect Power Ground +5 Volts DC

6-pin Male Mini-DIN Pin Function 1 Keyboard Data 2 No Connect 3 Power Ground 4 +5 Volts DC 5 PC Clock 6 No Connect

Adapter Cable Pin 1 2 3 4 5

5-pin Male DIN Function PC Clock PC Data No Connect Power Ground +5 Volts DC

6-pin Female Mini-DIN Pin Function 1 Keyboard Data 2 No Connect 3 Power Ground 4 +5 Volts DC 5 Keyboard Clock 6 No Connect

45

Page 50

LIMITED WARRANTY The MS7220 ArgusSCAN® scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility and its Suzhou, China facility. The MS7220 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS7220 scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and local laws, regulations and ordinances pertaining to their production and labeling. This warranty is limited to repair, replacement of product or refund of product price at the sole discretion of Metrologic. Faulty equipment must be returned to one of the following Metrologic repair facilities: Blackwood, New Jersey, USA; Madrid, Spain; or Suzhou, China. To do this, contact the appropriate Metrologic Customer Service/Repair Department to obtain a Returned Material Authorization (RMA) number. In the event that it is determined the equipment failure is covered under this warranty, Metrologic shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit and return such repaired or replaced Product without charge for service or return freight, whether distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase price. This limited warranty does not extend to any Product which, in the sole judgment of Metrologic, has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage due to use or misuse produced from integration of the Product into any mechanical, electrical or computer system. The warranty is void if the case of Product is opened by anyone other than Metrologic’s repair department or authorized repair centers. THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES, INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY. IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN.

CORPORATE HEADQUARTERS, NORTH AMERICA

METROLOGIC EUROPEAN REPAIR CENTER (MERC)

Metrologic Instruments, Inc. 90 Coles Rd. Blackwood, NJ 08012-4683 Customer Service Department Tel: 1-800-ID-METRO Fax: 856-228-6673 Email: info@metrologic.com

Metrologic Eria Ibérica, SL C/Alfonso Gomez, 38-40, 1D 28037 Madrid Tel: +34 913 751 249 Fax: +34 913 270 437

MTLG AUTO ID INSTRUMENTS (SHANGHAI) CO., LTD Suzhou Sales Office BLK A, Room# 03/03-04 No.5 Xinghan Street, Xinsu Industrial Square China-Singapore Suahou Industrial Park, Suzhou, PRC Tel: 86-512-67622550 Fax: 86-512-67622560 Email: info@cn.metrologic.com