Page 1
METROLOGIC INSTRUMENTS, INC. MS7120 Series Fixed Projection Laser Scanner Installation and User’s Guide
MLPN 2408 Printed in USA December 1998
Page 2
Locations USA Corporate Headquarters Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012 Customer Service: 1-800-ID-METRO Tel: 609-228-8100 Fax: 609-228-6673 info@metrologic.com www.metrologic.com
Europe Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany Tel: 49-89-89018-0 Fax: 49-89-89019-200 metrologic@europe.metrologic.com
ASIA Metrologic Asia (PTE) Ltd. 31, Khaki Bukit Road 3 #05-08 Techlink Singapore 417818 Tel: 65-842-7155 Fax: 65-842-7166 ant888@cyberway.com.sg
South America Metrologic Instruments Rua Flórida, 1.821-5°Andar-Brooklin CEP 04571-090, São Paulo-SP, Brasil Outside Brazil: Tel: 55-11-5505-6568 Fax: 55-11-5505-1681 info@sa.metrologic.com In Brazil: Tel: 55-11-5505-2396 Fax: 55-11-5507-2301 metrolog@br.metrologic.com Copyright
© 1998 by Metrologic® Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.
ii
Page 3
Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Scanner and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Quick Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Operational Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Scanner Installation: Powered by External Power Supply . . . . . . . . . . . . . . . 5 Scanner Installation: Powered by the Host Device . . . . . . . . . . . . . . . . . . . . . 6 Scanner Installation: to the PC for the Scanner with built-in PC Keyboard Wedge Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Scanner Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Audible Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Failure Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Visual Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Depth of Field Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Optimal Low Density Depth of Field . . . . . . . . . . . . . . . . . . . . . . 13 Optimal High Density Depth of Field . . . . . . . . . . . . . . . . . . . . . . 13 Close Depth of Field . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Normal Depth of Field . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Far Depth of Field . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Minimum Bar Code Element From Scanner Face . . . . . . . . . . . . . . . . . . . . 16 Optimal Low Density Depth of Field . . . . . . . . . . . . . . . . . . . . . . . 16 Optimal High Density Depth of Field . . . . . . . . . . . . . . . . . . . . . . 17 Close Depth of Field . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Normal Depth of Field . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Far Depth of Field . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-26 RS-232 Demonstration Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Application and Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 iii
Page 4
Table of Contents (continued) Appendix A Design Specifications
29, 30
Appendix B Default Settings
31-35
Appendix C Pin Assignments
36-38
Appendix D Warranty and Disclaimer
39, 40
Appendix E Notices
41, 42
Index
43, 44 iv
Page 5
Introduction Orbit™ is an aggressive, omnidirectional laser bar code scanner. Light-weight and rugged, Orbit is small in size, but BIG in performance. Designed for applications where counter space is limited, Orbit is the ideal presentation scanner for retail, convenience, liquor and specialty stores. In addition, Orbit’s unique, contoured shape allows it to be picked-up and used as a hand-held scanner when scanning large or bulky items. Engineered with a large, easy-to-find optimal scan area, Orbit increases the first pass read rate for maximum productivity. The scanning head can be tilted vertically a full 30o for added flexibility when scanning various sized objects. These features increase the scanning throughput without increasing the scanner size.
SCANNER
INTERFACE
7120-41
Full RS-232C and Light Pen Emulation
7120-47
Keyboard Wedge, Stand-Alone Keyboard and RS-232 Transmit/Receive
7120-9
OCIA and RS-232 Transmit/Receive
7120-11
IBM 46XX/RS-232C
7120-67
Full RS-232C and Light Pen Emulation
Orbit offers a great deal of features to the consumer: ‚ ‚ ‚ ‚ ‚ ‚
Fully automatic scanning operation PowerLink compatible Data editing 7 beeper tones Programmable depth of field Easy programming
1
Page 6
Scanner and Accessories The following is a list of the parts included in the MS7100 kit. !
MS7120 Laser Scanner - Refer to page 28 for available communication protocols
!
Power Transformer AC in 120V, 220V- 240V Continental European or 220V- 240V UK. DC in regulates 5.2V@650mA (MLPN45593/45591/45592)
RS-232, Light Pen, OCIA and 46xx scanners:
!
PowerLink cable with built in power jack: Standard - MLPN 54xxx* - 2.1m (7') straight cord, short strain relief or Optional - MLPN 53xxx* - 2.7m (9') coiled cord, long strain relief
*xxx specifies connection to the host Keyboard Wedge Scanners:
!
Keyboard Wedge PowerLink Cable with a 5-pin DIN female connector and a 6-pin mini DIN male connector (MLPN 19763)
!
Adapter Cable with a 5-pin DIN male connector and a 6-pin mini DIN female connector (MLPN 19716)
Available on the Metrologic Website (www.metrologic.com):
!
MetroSelect Programming Guide (MLPN 2407)
!
MS7120 User’s and Installation Guide (MLPN 2408)
Options
!
Counter/Wall Mount Kit (MLPN 45619)
Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876. 2
Page 7
Quick Start 1.) Plug in the scanner. When the MS7120 is ready to scan, the green LED will turn on, then the red LED will flash and the scanner will beep once. (the red LED will remain on for the duration of the beep).
2.) The scanner is shipped from the factory programmed with default settings. To configure the MS7120 scanner to meet the host system’s specific needs, refer to the MetroSelect Programming Guide (MLPN 2407) for instructions on how to enter the program mode and to select the appropriate bar codes.
3
Page 8
Operational Test Metrologic recommends using the external power supply provided with the scanner when operating the MS7120. When using power supplied by the host, the host system should supply a minimum of 250 mA of current @ 5VDC. Keyboard Wedge Scanners:
1.
Connect the 10-pin modular plug of the PowerLink cable into the scanner jack. Connect the other end of the PowerLink Y-type cable to the PC. Connect the 5-pin female DIN side of the Y-type cable into the keyboard connector on the PC and connect the 6-pin male mini-DIN side into the PC.
2.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. Connect AC power to the transformer.
3.
Listen for a single beep that indicates the scanner is ready for use. (steady green LED and the red LED will flash once)
RS-232, Light Pen, OCIA and 46xx scanners:
1.
Connect the 10-pin modular plug of the PowerLink cable into the scanner jack. Connect the other end of the PowerLink cable (the 9-pin D-type connector) to the PC.
2.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. Connect AC power to the transformer.
3.
Listen for a single beep that indicates the scanner is ready for use. (steady green LED and the red LED will flash once)
4
Page 9
Scanner Installation: Powered by External Power Supply To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. 1. Turn off the host system. 2. Make the necessary PowerLink cable connections to the scanner and the host. 3. Connect the external transformer into the power jack on the Power Link cable. 4. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. (the socket-outlet shall be installed near the equipment and shall be easily accessible.) Connect AC power to the transformer. 5. Turn on the host system.
NOTE: a. When the scanner first receives power, the green LED will turn on. Then the scanner will beep once and the red LED will flash simultaneously. b. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.
5
Page 10
Scanner Installation: Powered by Host Device The MS7120 scanner interfaces terminate to a 10-pin modular jack. Connect the 10-pin modular plug of the PowerLink cable into the jack then connect the other end of the PowerLink cable to the host. Refer to Appendix C page 36 for pin assignments. 1.
Turn off the host system.
2.
Make the necessary PowerLink cable connections to the scanner and the host.
3.
Turn on the host system.
NOTE: a. When the scanner first receives power, the green LED will turn on. Then the scanner will beep once and the red LED will flash simultaneously. b. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.