The text of a manual · part 16 of 19
MetroSelect Configuration Guide, Books 1 and 2: MetroSelect, Book 2 of 2, pages 147 to 156
Pages 147 to 156 of 184, from MetroSelect Configuration Guide, Books 1 and 2
The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Metrologic MS7120
Page 147
SECTION J
SET NARROW ELEMENT WIDTH /LASER EMULATION
* 1 ms Narrow Element Width
60 µs Narrow Element Width
³
³
8 1 6 8 1 6 3 0
8
1
6
8
1
0
This option allows the transmission of Light/Pen Wand emulation a 1 ms narrow element width.
This transmits at 60 µs narrow element width.
100 µs Narrow Element Width
500 µs Narrow Element Width
³
8
1
6
8
1
6
0
³
8
1
6
8
8
2
0
0
This transmits at 100 µs narrow element width.
This transmits at 500 µs narrow element width.
~ Variable Narrow Element Width †
Laser Emulation † Refer to the Multi-Code Method on page x.
³
9
1
6
8
0
0
³
9
9
9
Sets the minimum x-dimension in 6 µs increments. Scan this code followed by a 3 digit code byte sequence found in Section M. †
Light Pen/Laser Emulation
J
3
9
7
9
Page 148
Page 149
SECTION K
IBM 46XX CONFIGURATION/IBM PORTS
Load IBM 46xx Defaults
³
9
9
9
9
Enable IBM 46xx Communication
9
5
Load default format settings for IBM 46xx systems.
³
4
1
5
5
0
4
Select this option for IBM 46xx SIOC/RS485 communication. Not all scanners support this interface. The correct interface board is required.
IBM Port 17B 3687-2 In Counter
³
3
1
7
2
IBM Port 5B 1520 HH Laser
5
0
³
3
1
7
2
IBM Port 9B 4500 CCD HH BCRI
³
3
1
7
2
7
0
IBM 46xx Configuration
K
1
6
0
Page 150
IBM 46xx Configuration
SECTION K
3
1
7
2
IBM Reserve #2
0
0
IBM Reserve #3
³
3
1
7
2
3
1
7
2
³
3
1
7
2
1
0
3
0
IBM Reserve #4
2
0
4
0
IBM Reserve #5
³
2
IBM RESERVE CODES
IBM Reserve #1
³
K
³
3
1
7
2
Page 151
SECTION M
CODE BYTE USAGE
User configurable prefixes, symbol length and other features that use these code bytes for configuration, require that the scanner be in configuration mode. Scan the Enter/Exit Configuration Mode bar code before starting the configuration cycle. Single code configuration mode does not work for these multi-code sequences. Enter/Exit Configuration Mode
³
9
9
9
9
9
9
EXAMPLE User configurable prefix/suffix characters (Section E) can be saved into the scanner by scanning the 3 digit decimal equivalent of the ASCII character into the appropriate character location with the code byte bar codes. To add an asterisk (*) as a prefix scan the following bar codes in order: 1.
Enter/Exit Configuration Mode
(3 beeps)
2.
Configurable Prefix 1
(1 beep)
3.
Code Byte 0
(1 beep)
4.
Code Byte 4
(2 beeps)
5.
Code Byte 2
(3 beeps)
6.
Enter/Exit Configuration Mode
(3 beeps)
Code Bytes
M
1
Page 152
Code Bytes
SECTION M Code Byte 0
³
0
Code Byte 2
³
2
Code Byte 4
³
4
M
2
CODE BYTES 0-5 Code Byte 1
³
1
Code Byte 3
³
3
Code Byte 5
³
5
Page 153
SECTION M
CODE BYTES 6-9
Code Byte 6
³
Code Byte 7
6
³
Code Byte 8
³
7
Code Byte 9
8
³
Code Bytes
9
M
3
Page 154
Code Bytes
SECTION M
M
4
RESERVED CODES ~ Enable Reserved Code
³
9
9
9
9
8
8
Contact a Metrologic customer service representative for additional details on this feature.
~ Disable Reserved Code
³
9
9
9
9
8
7
Page 155
SECTION M
CODE BYTE/CODE TYPE TABLE
CODE BYTE
CODE TYPES
004
UPC-A
002
UPC-E
003
EAN-8
005
EAN-13
080
Code 39
081
Codabar
082
Interleaved 2 of 5
083
Code 128
084
Code 93
091
MSI Plessey
092
Code 11
093
Airline 2 of 5 (15 digits)
094
Matrix 2 of 5
095
Telepen
096
UK Plessey
098
Standard 2 of 5
097
Airline (13 digits)
099
TRI-OPTIC
Code Bytes
M
5
Page 156
Code Bytes
SECTION M
M
6
ASCII REFERENCE TABLE
HEX VALUE
DECIMAL VALUE/ CODE BYTE VALUE
CHARACTER
CONTROL KEYBOARD EQUIVALENT
00
000
NUL
@
01
001
SOH
A
02
002
STX
B
03
003
ETX
C
04
004
EOT
D
05
005
ENQ
E
06
006
ACK
F
07
007
BEL
G
08
008
BS
H
09
009
HT
I
0A
010
LF
J
0B
011
VT
K
0C
012
FF
L
0D
013
CR
M
0E
014
SO
N
0F
015
SI
O
10
016
DLE
P
11
017
DC1
Q
12
018
DC2
R
13
019
DC3
S
14
020
DC4
T
15
021
NAK
U
16
022
SYN
V
17
023
ETB
W
18
024
CAN
X
19
025
EM
Y
1A
026
SUB
Z