Filed in the catalog under the Metrologic MS7120

Page 91

SECTION E

LONGITUDINAL REDUNDANCY CHECK (LRC)

Enable Transmit of LRC Calculation

³

1

0

7

8

* Disable Transmit of LCR Calculation

1

1

³

1

0

7

8

0

1

The scanner outputs an LRC check character after the bar code.

The scanner will not output an LRC (check character) after the bar code.

* Start LRC on First Byte

Start LRC on Second Byte

³

³

1

0

7

8

0

0

The scanner will calculate the LRC check digit starting with the first character.

1

0

7

8

1

0

The scanner will calculate the LRC check digit starting with the second character.

Prefixes/Suffixes

E

15

Page 92

Prefixes/Suffixes

SECTION E

E

16

CONFIGURABLE SUFFIXES, ALL DATA

Scan the Enter/Exit Configuration Mode bar code before trying to set this feature. Refer to the Multi-Code Method on page x. Enter/Exit Configuration Mode

³

9

9

9

9

9

~ Configurable Suffix Character #1

9

³

9

0

4

5

0

0

A suffix ID can be added and assigned for data transmission. Use this code with a 3 code byte sequence from Section M of Book 2 that represents the desired character.

~ Configurable Suffix Character #2

³

9

0

4

6

0

~ Configurable Suffix Character #3

0

Assigns a 2nd configurable suffix character.

³

9

0

4

7

0

0

Assigns a 3rd configurable suffix character.

Page 93

SECTION E

CONFIGURABLE SUFFIXES, ALL DATA

~ Configurable Suffix Character #4 †

³

9

0

4

8

0

~ Configurable Suffix Character #5 †

0

³

Assigns a 4th configurable suffix character.

9

0

4

9

0

0

Assigns a 5th configurable suffix character.

† While using the Multi-Code method, scan this bar code followed by the 3 code byte bar codes in Section M of Book 2 that represents the desired character. (Refer to the Multi-Code method on page x.)

~ Configurable Suffix Character #6 †

³

9

0

5

0

0

~ Configurable Suffix Character #7 †

0

³

Assigns a 6th configurable suffix character.

9

0

5

1

0

0

Assigns 7th configurable suffix character.

Prefixes/Suffixes

E

17

Page 94

Prefixes/Suffixes

SECTION E

9

0

5

2

18

CONFIGURABLE SUFFIXES, ALL DATA

~ Configurable Suffix Character #8 †

³

E

0

~ Configurable Suffix Character #9 †

0

³

9

0

5

3

0

0

Assigns a 8th configurable suffix character.

Assigns a 9th configurable suffix character.

~ Configurable Suffix Character #10 †

† While using the MultiCode method, scan this bar code followed by the 3 code byte bar codes in Section M of Book 2 that represents the desired character. (Refer to the Multi-Code method on page x.)

³

9

0

5

4

0

0

Assigns a 10th configurable suffix character.

* Clear All User Configurable Suffixes

³

9

9

9

9

8

4

Page 95

SECTION E

SPECIAL FORMATS

Enable SINEKO Mode

* Disable SINEKO Mode

³

1

0

7

9

1

4

³

Enable Newcode Formatting Mode A

³

1

1

6

7

1

1

6

7

0

7

9

0

4

* Disable Newcode Formatting Mode A

1

1

³

Enable Newcode Formatting Mode B

³

1

1

1

6

7

0

1

* Disable Newcode Formatting Mode B

1

0

³

Prefixes/Suffixes

1

E

1

19

6

7

0

0

Page 96

May 2002 Printed in the USA

00 - 02407B - 1