For the Metrologic MS700

Page 11

Configuring the Scanner Located in the Version 11 scanner are two computer boards. One board is for decoding and the other for 46XX IO processing. The decode board is configured using ScanSet™ or ScanSelect™ while the IO board is configured with an internal DIP Switch bank. For UPC/EAN scanning, the decode board should be set as follows: Enable IBM 4680 Communication Enable UPC/EAN Beep after Transmit Enable Communication Timeouts Transmit UPC-A Check Digit Transmit UPC-E Check Digit These settings configure the decode board to beep after transmitting the data to the terminal device driver. If the data does not clear the communications buffer within two seconds, it is discarded without giving the operator a good scan indication. This accommodates newer versions of the IBM device drivers that enable/disable scanning in many different situations. The default setting of the interface board is to emulate the IBM 1520 hand scanner that supports UPC/EAN and alphanumeric code types. The following is a list of switch settings for the internal interface board that handles the 46XX SIOC communications. There are eight DIP switches on the board that are both software and hardware switches. Switch 1

Switch 2

Emulation Mode

OFF

OFF

OFF ON ON

ON OFF ON

Port 5B, IBM 1520 Model 2 Laser Scanner (default setting) Port 9B, CCD (IBM 4500/Opticon) Port 17, IBM 4014 Adaptor for 3687-2 to 468X Reserved

Switch 3 Switches 4, 5, 6, and 7 Switch 8

Reserved (Should be OFF) Must be ON Should be OFF (Reserved)

7

Page 12

Configuring the IBM 46XX The 4683 and 4693 terminals are configured on the store controller. The 4684 and 4694 terminals are typically configured on the individual terminals. Follow the appropriate guide for the type of equipment. IBM 4683 and 4693 Terminals Driven by a 46XX Store Controller Running 4680.OS or 4690.OS Access the terminal configuration menu on the store controller. If not already selected, select an IBM 1520 laser hand scanner (4680.OS Port 5B), an IBM 4500 hand-held bar code reader (CCD, 4680.OS Port 9B), or an IBM 3687-2 fixed scanner (4680.OS Port 17) that matches the configuration of the scanner. Regarding the 4690.OS, at the time of this printing, Metrologic does not know exactly which terminal port configuration screen is used for selecting scanners. It should be listed under the Port 9A, 9B, 9C, or 9E sections. The 4693 terminal has a Port 5B that was originally used for the IBM 1520 scanner. While IBM has withdrawn this product, it was not clear how terminal configuration and device driver support would be provided for the installed base of users. Save the configuration and activate it for the desired terminals. Download the configuration to the terminal(s) per standard procedures. IBM 4684 and 4694 Systems Initialize the RIPPS drivers for a hand scanner if hand scanner emulation was selected. Initialize the RIPPS drivers for a "POS scanner" if the 3687-2 scanner has been selected.

8

Page 13

Scanner Installation to a PC Keyboard Port The MS700i/MS715i/MS720i/ scanner (version 17) provides keyboard emulation by converting the scanned bar code data to the PC keyboard scan code equivalent. The following are the supported keyboard and country types: PC Type ! AT (includes IBM PS/2 and compatible models 50, 55, 60, 80) ! XT ! PS/2 (includes IBM PC and compatible models 30, 70, 8556) ®

Keyboard Country Type ! ! ! !

USA France Italy Belgium

! ! ! !

United Kingdom Germany Spain Swiss

The communication cable kit (MLPN: 45927) has a communication cable with one (1) 5 Pos female DIN connector and one (1) 6 Pos male mini DIN connector. The kit also includes an adaptor cable. This cable allows the scanner to plug into an IBM® PC XT or AT compatible computer or a PS/2 computer and keyboard. With the appropriate communication cable, the scanner will also provide RS232 or light pen emulation interface. When configuring the scanner for one interface versus another, change all necessary parameters for that particular interface. For instance, to configure the scanner for keyboard wedge emulation, recall defaults, select the PC type, keyboard country type and intercharacter delay. For further information, refer to the ScanSelect™ Scanner Programming Guide or ScanSet™ Scanner Configuration Guide.

9

Page 14

To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. 1. When connecting to a PS/2 computer, attach to the communication cable (#51573) the 5M 6F adaptor to the female connector and the 5F 6M adaptor to the male connector. 2. If the PC is on, exit the application and turn the PC off.

Figure 1

3. Disconnect the keyboard from the PC. 4. Plug the communication cable to the PC and the keyboard. (Refer to Figure 1). 5. Connect the 25-pin D-type connector on the scanner’s head cable to the communication cable. 6. Check the AC input requirements of the transformer to make sure the voltage matches the AC outlet. (A socket-outlet shall be installed near the equipment and shall be easily accessible.) 7. Plug the transformer into the side of the female D-type connector located on the communication cable. Plug the transformer into the AC outlet to supply power to the scanner. 8. Turn the PC on.

10

Page 15

PC Application Note: For most applications, it will be desirable to disable linefeed transmission. For non-USA keyboards, 10 mesc is probably the best intercharacter delay. Network system installations, may require tuning of the intercharacter and inter scan code options. Note: Once the scanner connects to the PC, the PC can be turned on and will operate normally even if the scanner's transformer plug is not in. However, bar codes will not be read until the scanner receives power. When the scanner first receives power, the LEDs will flash and then the scanner will beep once. After the scanner performs this startup sequence, the green LED will remain on for a specified time indicating the laser is on.

11

Page 16

Installation of the MS700 Series Stand The following are components used to build the MS700 Series stand (MLPN: 45483):

Figure 2

1 2 3

Shoe Mount Stand Cover Stand Base

4 5 6 7

Four Wood Screws One Machine (¼-20) Screw Internal Lock Washer Flexible Shaft

1. Use the 2½ inch x 2½ inch stand base to mark the position for pilot holes. 2. Use the four wood screws to secure the base to the work surface. 3. Position the stand cover on top of the stand base. 4. Screw the flexible shaft to the stand base. 5. Place the internal lock washer on top of the flexible shaft and then screw the shoe to the shaft with the machine screw.

12

Page 17

Attaching the Scanner to the Stand Once the stand is securely mounted to the work surface, attach the scanner. The scanner has a “foot” that is at the bottom of the scanner. This foot fits into the “shoe” attached to the top of the stand. This construction helps prevent the scanner from being knocked from the stand. 1. To prevent obstruction when sliding the scanner into place, loosen the small screw (A) located in the center of the long part of the shoe with a 3/32" hex key wrench. (Refer to Figure 3) 2. Align the foot of the scanner with the shoe of the stand and slide the scanner into position. 3. Tighten the small screw (A) located at the center of the long part of the shoe. This screw holds the scanner in place. Note: Fasten the stand to the work surface before adjusting the angle of the flexible shaft. To adjust the angle, firmly hold the shaft and push the shaft to a north, south, east, or west direction.

Figure 3

13

Page 18

MS700i and MS720i Series Features

Figure 4

1

Speaker

The sound of a beep emits from here when the scanner performs a good read of a bar code.

2

Green and Red LEDs

When the green LED is on, this indicates that the unit is receiving power and the laser is on. When the red LED flashes on, the scanner has read a bar code successfully. When the red light turns off, communication to the host is complete.

3

InfraRed Object Sensor

When a specified time has elapsed without any scanning, the unit will enter a “standby” mode. The scanner will not return to scanning until an object or a wave your hand is passed in front of the IR sensor.

4

Head Cable

This cable can connect directly to the host device or to a communication cable.

5

Output Window

This aperture emits laser light.

14

Page 19

Visual Indicators There is a red LED and a green LED located on the scanner. When the scanner is on, the flashing or stationary activity of the LEDs alert you to the status of the scan and scanner. No Red or Green LED There are two reasons why the LEDs will not be illuminated. First, if the scanner is receiving power and the LEDs are not on, then the scanner has remained dormant for a specified period of time and the laser has turned off. To reactivate the unit, wave an object in front of the IR sensor. Secondly, if the scanner is not receiving power from the host or transformer, then the LEDs will not turn on. Steady Green When the laser is on, the green LED is also on. This occurs when an object is in the scan field. The green LED will remain on until the IR time-out has elapsed or until the scanner is turned off. Steady Green; Red Flash When the scanner successfully reads a bar code, the red LED will flash followed by one beep. If you do not see the red LED flash or the scanner beep once, then the bar code has not been successfully read. Steady Red and Green After a successful scan, the scanner transmits the data to the host device. When the host is not ready to accept the information, the scanner’s red LED will remain on until the data can be transmitted. Alternating Red and Green This indicates the scanner is in program mode. Steady Red This indicates the scanner is in ScanSet mode. Flashing Red This indicates the scanner has experienced a laser subsystem failure. Return the unit for repair at an authorized service center.

15

Page 20

Signaux optiques Sur la partie supérieure du scanner se trouvent une diode LED rouge et une diode LED verte. Quand le scanner est sous tension, les diodes rouge et verte clignotantes ou allumées vous informent sur l'état du scanner. Ni la diode rouge, ni la diode verte n'est allumée Il existe deux raisons possibles pour que les diodes ne s'allument pas. Premièrement: si le scanner reçoit de l'énergie sans que les diodes ne s'allument, le scanner est resté sans servir pendant une certaine période et le laser est désactivé. Pour le réactiver, passer un objet devant le palpeur infrarouge. Deuxièmement: quand le scanner ne reçoit de l'énergie ni de l'ordinateur central, ni du transformateur, les diodes restent éteintes. La diode verte reste allumée Quand le laser est en service, la diode verte s'allume également. C'est le cas quand un objet se trouve devant le palpeur. La diode verte reste allumée tant que la temporisation de l'infrarouge dure ou jusqu'à ce que le scanner soit désactivé. La diode verte reste allumée; la diode rouge clignote Après lecture avec succès d'un code à barres par le scanner, la diode rouge se met à clignoter, suivie d'un bip sonore unique. Si la diode rouge ne clignote pas ou quand aucun bip sonore n'est émis, cela signifie que le code à barres n'a pas pu être lu avec succès. Les diodes rouges et vertes restent allumées Une fois la lecture effectuée avec succès, le scanner transmet les données à l'ordinateur central. Si ce dernier n'est pas prêt à recevoir les données, la diode rouge du scanner reste allumée jusqu'à ce que les données puissent être transmises. Les diodes rouges et vertes clignotent en alternance Indique que le scanner se trouve en mode de programmation. La diode rouge reste allumée Indique que le scanner se trouve en mode ScanSet. Diode rouge clignotante Indique une panne de laser pendant la lecture. Veuillez envoyer votre appareil chez un concessionnaire pour réparation.

16