For the Metrologic MS700

Page 1

METROLOGIC INSTRUMENTS, INC. MS700i Series Laser Bar Code Projection Scanner Installation and User’s Guide

MLPN 2178 Printed in USA October 1998

Page 2

Locations: USA Corporate Headquarters Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012 Customer Service: 1-800-ID-METRO Tel: 609-228-8100 Fax: 609-228-6673 info@metrologic.com www.metrologic.com

Europe Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany Tel: 49-89-89018-0 Fax: 49-89-89019-200 metrologic@europe.metrologic.com

ASIA Metrologic Asia (PTE) Ltd. 31, Kaki Bukit Road 3 #05-08 Techlink Singapore 417818 Tel: 65-842-7155 Fax: 65-842-7166 ant888@cyberway.com.sg

South America Metrologic Instruments Rua Flórida, 1.821-5°Andar-Brooklin CEP 04571-090, São Paulo-SP, Brasil Outside Brazil: Tel: 55-11-5505-6568 Fax: 55-11-5505-1681 info@sa.metrologic.com In Brazil: Tel: 55-11-5505-2396 Fax: 55-11-5507-2301 metrolog@br.metrologic.com

Copyright © 1998 by Metrologic® Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.

ii

Page 3

Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Unpacking List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Scanner Connections to the Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Configuration of the Scanner to the Host System . . . . . . . . . . . . . . . . . . . . . . 4 Cloning Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Version 11 IBM 46XX Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Configuring the Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Configuring the IBM 46XX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 IBM 4683 and 4693 Terminals Driven by a 46XX Store Controller Running 4680.OS or 4690.OS . . . . . . . . . . . . 8 IBM 4684 and 4694 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Scanner Installation to a PC Keyboard Port . . . . . . . . . . . . . . . . . . . . . . . 9, 10 PC Application Note . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Installation of the MS700 Series Stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Attaching the Scanner to the Stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 MS700i and MS720i Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Visual Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-18 Volume Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 InfraRed (IR) Object Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Symbol Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Active Scan Region for the MS700i and MS715i Scanner . . . . . . . . . . . . . 23 Horizontal Scan Width vs. Distance for the MS700i and MS715i Scanner . 24 iii

Page 4

Active Scan Region for the MS720i Scanner . . . . . . . . . . . . . . . . . . . . . . . . 25 Horizontal Scan Width vs. Distance for the MS720i Scanner . . . . . . . . . . . 26 Depth of Field for the MS700i and MS715i Scanner . . . . . . . . . . . . . . . . . . 27 Depth of Field and Symbol Specification for the MS700i and MS715i . 28, 29 Depth of Field for the MS720i Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Depth of Field and Symbol Specification for the MS720i . . . . . . . . . . . 31, 32 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Applications and Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Appendix A Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34, 35 Appendix B Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-41 Appendix C Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42-46 Appendix D Warranty and Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47, 48 Appendix E Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49, 50 Appendix F Patents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Volume Control Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52, 53 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53, 54 iv

Page 5

Introduction The MS700i Series Scanners are high throughput projection scanners that incorporate the latest in VLD (Visible Laser Diode) ASIC/VLSI and surface mount technologies. Each scanner consumes only 8 watts of power and can directly connect to many host systems that can support a scanning device. One thoughtful feature is a “sleep mode” that turns the laser and motor off when not in use. Other features include easy-to-see LED indicators that can be viewed from the top or front and a volume control card that can be scanned to control volume levels. There are two programming methods: through the ScanSelect™ programming guide or through ScanSet™ (an IBM PC compatible software program.) With a scan speed of 2,000 lines per second, these scanners aggressively scan poorly printed bar codes and read torn and bent UPC, EAN and JAN bar codes immediately on the first pass at any roll angle. For close scanning, the MS700i and MS715i’s depth of field of 0.0mm - 178mm (0" - 7") is ideal. To accommodate applications where scanning items farther away from the scan window is preferred, the MS720i’s depth of field of 178mm - 381mm (7" 15") is ideal.

1

Page 6

Unpacking List The shipping carton should contain the following: !

Installation and User’s Guide (MLPN: 2178)

!

ScanSelect™ Scanner Programming Guide (MLPN: 2186)

!

Volume Control Card (MLPN: 2346)

!

MS700i /MS715i or MS720i Laser Bar Code Projection Scanner

!

Power Supply (optional)

!

Communication cable with connection for power supply (optional) or Communication Cable (optional)

!

Stand #45483 (optional)

If any item is missing or to order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-IDMETRO or 1-800-436-3876.

2

Page 7

Scanner Connections to the Host To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To avoid potential problems, do not power up the scanner until the communication cable is secured to the host. 1. Turn off the host system. 2. Connect the 25-pin D-type connector on the scanner’s head cable to the communication cable. Connect the other end of the communication cable to the host device. (If the scanner will not receive power from a transformer, skip to Step 5.) 3. If the scanner will receive power from an external power source, check the AC input requirements of the transformer to make sure the voltage matches the AC outlet. (A socket-outlet can be installed near the equipment so it will be easily accessible.) 4. Plug the transformer into the side of the female D-type connector located on the communication cable. Plug the transformer into the AC outlet to supply power to the scanner. 5. Power up the host system. Note: When the scanner first receives power, the LEDs will flash and then the scanner will beep once. After the scanner performs this startup sequence, the green LED will remain on for a specified time indicating that the laser is on.

3

Page 8

Configuration of the Scanner to the Host System The scanner is shipped from the factory programmed to a set of default conditions. These default conditions are in the Default Settings section of this guide pages 36-41 and in the ScanSelect™ Scanner Programming Guide. The default settings in the ScanSelect guide have an asterisk that appears before the brief definition next to the bar code. For the scanner to properly communicate with the host system, it needs to be programmed to meet the specific scanning needs. Since each host system is unique, configure the scanner to match the host system requirements. Configure the scanner by entering program mode and scanning the appropriate bar codes that appear in the ScanSelect Scanner Programming Guide. (When using ScanSet™, refer to the ScanSet documentation for information on how to configure the scanner.) 1. Connect the scanner to the host system (Refer to the Scanner Connections to the Host section in this guide). 2. Enter program mode by scanning the ENTER/EXIT program mode bar code as the first bar code after a power up cycle. (The unit will beep three times) 3. Scan the appropriate bar code(s) that appear in the ScanSelect Scanner Programming Guide. (Reveal only one bar code to the scanner each time. With your hand, cover the bar code that is not to be scanned.) 4. Exit program mode by scanning the ENTER/EXIT program mode bar code again. (The new options will be saved and the scanner is ready for normal operation.) Note: Non-RS-232 interfaces chosen in Section B of the ScanSelect Programming Guide do not match the default settings loaded when the same interface is selected with ScanSet.

4

Page 9

Cloning Feature To program several scanners with the same settings, use the Cloning feature. This is done by connecting the cloning cable (MLPN: #51544) between two scanners. 1. Turn off both scanners. 2. Connect the cloning cable between the two scanners. 3. Turn both scanners on by plugging in the transformers. 4. Once each scanner is ready, scan the cloning bar code with the scanner that has the settings that need to be transferred to the other scanner.

CLONING

5

Page 10

Version 11 IBM 46XX Scanner Output Format:

IBM RS-485 serial input/output for the 4680 and 4690 (46XX) point-of-sale terminals

The Version 11 46XX interface can be used in several different ways. Both the 46XX terminal and the scanner must be configured to match each other. Warning: Power to the scanner and 46XX terminal should be turned off before making physical connection. The 4680 and 4690 series terminals have different types of physical ports for connecting bar code scanners. Scanner ports include Port 5B, Port 17, and Port 9? (? = A, B, C, or E). A Port 9 type connector is present on all versions of the 46XX families of terminals. That is one reason it is the normal point of connection for Metrologic scanners. Another reason is that there is enough 12 volt power available to operate many Metrologic scanners. If the terminal configuration requires use of a different physical port for connecting bar code scanners, contact Metrologic to get particular adaptor cable information. No matter what port is in use for the physical connection, all devices use a common communications bus inside the 46XX terminal. Each device uses a different address when it must communicate. The terminal must be configured to look for a device at a logical address. The IBM 1520 mode/address was selected as a default because it was the first IBM 46XX family scanner to support UPC/EAN, Code 39 and Interleaved 2 of 5. The Version 11 scanner formats Codabar, Code 128, and Code 93 using the Code 39 function code designation supported by the IBM device driver for this scanner type. Other emulation modes currently available are the IBM 3687-2 Port 17 fixed scanner and the Port 9B IBM 4500 CCD hand-held bar code reader. One of these other emulation modes may be needed depending on which operating system (4680.OS, 4690.OS, POS/DOS or DOS/RIPPS) is in use at the site. Note:

6

The IBM 4683 and IBM 4684 terminals have a good proven track record of supplying power to Metrologic scanners. The IBM 4693 and IBM 4694 terminals may be restricted from supplying power to certain scanner models. Specifically, Metrologic currently recommends using an external power supply for the scanner when connecting to an IBM 4694. Metrologic has no recommendations at this time for IBM 4693 terminals.