The text of a manual · part 6 of 17
ScanSelect Scanner Programming Guide, pages 51 to 60
Pages 51 to 60 of 164
The original document is the PDF (376 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic MS6720
Page 51
Transmit UK Plessey Check Digits
0
12345
12917
9
When this option is chosen, the scanner will transmit UK Plessey’s check digit characters. This feature works in conjunction with the UK Plessey option in Section A.
*Do not Transmit UK Plessey Check Digits
0
12345
12907
0
When this option is chosen, the scanner will not transmit UK Plessey’s check digit characters. D-9
Page 52
Section E RS-232 Parameters All of the options in this section are available with RS-232 communication. However, some of the data formatting options also apply for keyboard wedge mode. E/D = Enable/Disable DN/T = Do Not Transmit/Transmit Odd/Space Parity Even/Mark Parity 19200/9600 Baud Rate 4800/2400 Baud Rate 1200/600 Baud Rate 300/38400 Baud Rate 8/7 Data Bits DN/T Sanyo ID Characters E/D Shell/Schulmberger Formatting E/D SNI Beetle Mode E/D French PC Term DN/T AIM ID Characters (Chrs.) E/D Nixdorf ID Program Prefix Chrs., RS-232 (Byte 1)/(Byte 2) Program Suffix Chrs., RS-232 (Byte 1)/(Byte 2) E/D UPC Prefix
(E - 1) (E - 1) (E - 2) (E - 2) (E - 3) (E - 3) (E - 4) (E - 4) (E - 5) (E - 5) (E - 6) (E - 6) (E - 7) (E - 7) (E - 8) (E - 8)
E/D UPC Suffix E/D STX Prefix E/D ETX Suffix E/D Carriage Return E/D Line Feed E/D Tab Prefix E/D Tab Suffix E/D DE Disable Command E/D FL Laser Enable Command E/D DTR Handshaking Support E/D RTS/CTS Handshaking Character/Message RTS/CTS E/D XON/XOFF Handshaking E/D ACK/NAK E/D 5 Retries ACK/NAK Time-out
E-i
(E - 9) (E - 9) (E - 10) (E - 10) (E - 11) (E - 11) (E - 12) (E - 12) (E - 13) (E - 13) (E - 14) (E - 14) (E - 15) (E - 15) (E - 16)
Page 53
Odd Parity
0
12345
Even Parity
20903
1
0
Parity is an extra bit attached to the transmitted data byte which is used to catch potential single-bit data transmission errors. The scanner's parity must match the host's parity. Select odd to make the additional parity bit either a 0 or 1 to guarantee that an odd number of bits are ones.
*Space Parity
0
12345
12345 20923 9 The scanner's parity must match the host's parity. Select even to make the additional parity bit either a 0 or 1 to guarantee that an even number of bits are ones.
Mark Parity
20913
0
0
Parity is an extra bit attached to the transmitted data byte which is used to catch potential single-bit data transmission errors. The scanner's parity must match the host's parity. Select space to make the parity bit always 0.
12345
20933
8
Parity is an extra bit attached to the transmitted data byte which is used to catch potential single-bit data transmission errors. The scanner's parity must match the host's parity. Select mark to make the parity bit always 1. E-1
Page 54
19200 Baud Rate
0
12345
4800 Baud Rate
31770
0
5
12345
31750
7
A baud rate is a unit that measures the speed with which information is transferred. The baud rate of the scanner must equal the baud rate of the host device. Select the rate that matches the host device’s requirements.
A baud rate is a unit that measures the speed with which information is transferred. The baud rate of the scanner must equal the baud rate o the host device. Select the rate that matches the host device’s requirements.
*9600 Baud Rate
2400 Baud Rate
0
12345
31760
0
6
12345
31740
8
A baud rate is a unit that measures the speed with which information is transferred. The baud rate of the scanner must equal the baud rate o the host device. Select the rate that matches the host device’s requirements.
A baud rate is a unit that measures the speed with which information is transferred. The baud rate of the scanner must equal the baud rate of the host device. Select the rate that matches the host device’s requirements. E-2
Page 55
1200 Baud Rate
0
12345
300 Baud Rate
31730
0
9
12345
31710
1
A baud rate is a unit that measures the speed with which information is transferred. The baud rate of the scanner must equal the baud rate of the host device. Select the rate that matches the host device’s requirements.
A baud rate is a unit that measures the speed with which information is transferred. The baud rate of the scanner must equal the baud rate o the host device. Select the rate that matches the host device’s requirements.
600 Baud Rate
38400 Baud Rate
0
12345
31720
0
0
12345
31700
2
A baud rate is a unit that measures the speed with which information is transferred. The baud rate of the scanner must equal the baud rate o the host device. Select the rate that matches the host device’s requirements.
A baud rate is a unit that measures the speed with which information is transferred. The baud rate of the scanner must equal the baud rate of the host device. Select the rate that matches the host device’s requirements. E-3
Page 56
8 Data Bits
0
12345
Transmit Sanyo ID Characters
11914
9
0
RS-232 serial communication requires ASCII data to be transmitted in either 7 or 8 data bits. In addition, one parity bit will be transmitted. If the host device requires 8 data bits, select this option.
*7 Data Bits
0
12345
12345 11916 3 When this option is chosen, the scanner will transmit code identifiers before each bar code. These identifiers are expected by many Sanyo registers.
*Do not Transmit Sanyo ID Characters
11904
0
0
RS-232 serial communication requires ASCII data to be transmitted in either 7 or 8 data bits. In addition, one parity bit will be transmitted.
12345
11906
4
When this option is chosen, the scanner will not transmit code identifiers before each bar code. E-4
Page 57
Enable Shell/Schulmberger Formatting
0
12345
11512
Enable SNI Beetle Mode
0
7
When this option is chosen, the scanner will output an LRC (check character) after the bar code. In addition, ETX suffix and STX prefix must be enabled while CR and LF must be disabled.
12345
12913
1
When this option is enabled, the scanner will transmit the ID characters that SNI Beetle cash register expects.
*Disable SNI Beetle Mode *Disable Shell/ Schulmberger Formatting
0
12345 11502 0 8 When this option is chosen, the scanner will not output an LRC (check character) after the bar code.
12345
12903
2
When this option is disabled, the scanner will not transmit the ID characters that the SNI Beetle cash register expects. E-5
Page 58
Enable French PC Term
12345
12914
Transmit AIM ID Characters
When this option is enabled, the scanner will transmit PC type make/break scan codes instead of ASCII data characters.
12345 11915 6 When this option is chosen, the scanner will transmit AIM symbology identifiers. Currently, the scanners do not support this feature.
*Disable French PC Term
*Do not Transmit AIM ID Characters
0
0
12345
12904
8
0
9
0
When this option is disabled, the scanner will not transmit PC type make/break scan codes instead of ASCII data characters. E-6
12345 11905 7 When this option is chosen, the scanner will not transmit AIM symbology identifiers. Currently, the scanners do not support this feature.
Page 59
Enable Nixdorf ID
0
12345
Programmable Prefix Characters, RS-232 (Byte1)
11917
0 0
When this option is enabled, the scanner will transmit the code identifiers before each bar code. Many Siemens/Nixdorf registers require these code identifiers.
12345
11907
92000
4
When this option is chosen, one programmabl prefix ID character can be assigned and added to the scanned data transmission. To specify the character, scan the above bar code and the appropriate Code Byte in Section I. Programmable Prefix Characters, RS-232 (Byte 2)
*Disable Nixdorf ID
0
12345
0
1
12345
92100
1
When this option is chosen, a second programmable prefix ID character can be assigned and added to the scanned data transmission. To specify the second character, scan the above bar code and the appropriate Code Byte in Section I.
When this option is chosen, the scanner will not transmit the code identifiers before each bar code.
E-7
Page 60
Programmable Suffix Characters, RS-232 (Byte1)
0
12345
92200
Enable UPC Prefix
8
0
12345
11817
3
When this option is chosen, one programmable suffix ID character can be assigned and added to the scanned data transmission. To specify the character, scan the above bar code and the appropriate Code Byte in Section I.
When this option is enabled, the scanner will transmit a prefix before any UPC/EAN bar code. The prefixes are A (UPC-A), EO (UPCE), F (EAN-13) and FF (EAN-8).
Programmable Suffix Characters, RS-232 (Byte2)
*Disable UPC Prefix
0
12345
92300
5
0
12345
11807
4
When this option is chosen, the scanner will not transmit a prefix before any UPC/EAN bar code.