The text of a manual · part 16 of 17
ScanSelect Scanner Programming Guide, pages 151 to 160
Pages 151 to 160 of 164
The original document is the PDF (376 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic MS6720
Page 151
Function keys F1 - F12 and other keys (No E0H required) KEY
AT SCAN CODE
XT/PS2 SCAN CODE
CODE BYTE
3BH
PREFIX/SUFFIX VALUE HEX DECIMAL 90H = 144
F1
05H
F2
06H
3CH
91H = 145
F3
017
04H
3DH
92H = 146
018
F4
0CH
3EH
93H = 147
019
F5
03H
3FH
94H = 148
020
F6
0BH
40H
95H = 149
021
F7
83H
41H
96H = 150
022
F8
0AH
42H
97H = 151
023
F9
01H
43H
98H = 152
024
F10
09H
44H
99H = 153
025
F11
78H
57H
9AH = 154
026
016
F12
07H
58H
9BH = 155
027
NUMERIC +
79H
4EH
9CH = 156
028
NUMERIC -
7BH
4AH
9DH = 157
029
NUMERIC *
7CH
37H
9EH = 158
030
CAPS LOCK
58H
3AH
9FH = 159
031
NUM LOCK
77H
45H
A0H = 160
032
LEFT ALT KEY
11H
38H
A1H = 161
033
LEFT CTRL KEY
14H
1DH
A2H = 162
034
LEFT SHIFT
12H
2AH
A3H = 163
035
RIGHT SHIFT
59H
36H
A4H = 164
036
I - 36
Page 152
Section J 6720 Specific Codes All of the options in this section are available with the 6720 scanner. Projection vs Hand Held Scanner Modes and IR Sensor Hand Held Scanner Operation Mode *Scanner Projection Mode *10 Minutes IR Time-outs - Projection 5 Second Laser Off - Hand Held 2 Minutes IR Time-outs - Projection 2 Second Laser Off - Hand Held 30 Minutes IR Time-outs 10 Second Laser Off - Hand Held No IR Time-outs - Projection and Hand Held Depth of Field /IR Range Sensor Switch *Normal DOF in the Stand IR Long Range Extended DOF in the Stand IR Long Range Close DOF in the Stand IR Short Range Optional DOF in the Stand IR Long Range *Normal DOF out of Stand IR Long Range Extended DOF out of Stand IR Long Range
DOF = Depth of Field (J - 1) (J - 2) (J - 2) (J - 2) (J - 2) (J - 3) (J - 3) (J - 3) (J - 3) (J - 4) (J - 4) (J - 4) (J - 4) (J - 5)
J-i
Close DOF out of Stand IR Short Range Optional DOF out of Stand IR Long Range MS6720 with 4680 IO Processor IBM 468x RS-485 SIOC Scanner Emulation IBM 1520 Emulation IBM 4500 CCD Emulation IBM 3687-2 Emulation MS6720 - Light Pen/Wand Emulation Units 10x Border *50x Border .15ms Narrow Element 0.3ms Narrow Element 0.5ms Narrow Element 1.0ms Narrow Element
(J - 5) (J - 5) (J - 6) (J - 7) (J - 7) (J - 7) (J - 7) (J - 8) (J - 8) (J - 9) (J - 9) (J - 9) (J - 9) (J - 10)
Page 153
Projection vs Hand Held Scanner - Modes and IR Sensor When the Projection Scanner (default) Mode bar code is chosen the scanner will behave like an MS700. The IR sensor is used to “wake” the scanner up for an extended period of time. These bar codes have the following features: Bar Code 10 min IR Timeout 2 min IR Timeout 30 min IR Timeout No IR Timeout
Laser Off/Motor Off 10 mins 2 mins 30 mins Always On
When the Hand Held Scanner Operation Mode bar code is chosen, the scanner will behave like an MS951. It will look for data only after the IR sensor has been activated. These bar codes have the following features: Bar Code
Laser Off
10 min IR Timeout 2 min IR Timeout 30 min IR Timeout No IR Timeout
5 secs 2 secs 10 secs Always On
J-1
Page 154
Hand Held Scanner Operation Mode
0
12345
11311
*10 Minutes IR Time-outs - Projection 5 Second Laser Off - Hand Held
6 0
When this option is chosen, the scanner will behave like an MS951. It will look for data in response to an IR sensor activation.
12345
11301
20930
7
This time represents the duration of time of inactivity from the last scan until the scanner enters a “standby” mode. The scanner will not return to scanning until an object is waved in front of the IR sensor.
2 Minutes IR Time-outs - Projection 2 Second Laser Off - Hand Held
*Scanner Projection Mode
0
12345
7
0
When this option is chosen, the scanner will behave like an MS700. It will look for bar code data as long as the scanner is awake, regardless of the IR sensor status.
12345
20920
8
This time represents the duration of time of inactivity from the last scan until the scanner enters a “standby” mode. The scanner will not return to scanning until an object is waved in front of the IR sensor. J-2
Page 155
30 Minutes IR Time-outs - Projection 10 Second Laser Off - Hand held
0
12345
20910
Depth of Field/IR Range Sensor Switch The scanning process can be initiated by an infrared (IR) device that is below the output window. The depth of field for the scanner is 0"8". The following bar codes are 8 combinations of the Depth of Field/IR Activation operations currently available. With these bar codes, the scanner can:
9
This time represents the duration of time of inactivity from the last scan until the scanner enters a “standby” mode. The scanner will not return to scanning an object is waved in front of the IR sensor.
a.) sense when it is in or out of the stand b.) adjust the scanning depth of field c.) adjust the depth of field in which the IR sensor activates
*Normal Depth of Field in the Stand IR Long Range
No IR Time-outs - Projection and Hand Held
0
12345
20900
0
0
12345
23100
1
When this option is selected, the scanner will be configured for Normal Depth of Field and Long Range IR when operated in the stand.
When this option is chosen, the scanner will not enter a “standby” mode. When using a Tech scanner, select this option since these units do not have an IR sensor or a touchplate. J-3
Page 156
Extended Depth of Field in the Stand IR Long Range
0
12345
23110
Optional Depth of Field in the Stand IR Long Range
0 0
When this option is selected, the scanner will be configured for Extended Depth of Field and Long Range IR when operated in the stand.
12345
23120
23130
8
Do not scan this bar code unless instructed to do so by a Metrologic representative.
*Normal Depth of Field out of Stand IR Long Range
Close Depth of Field in the Stand IR Short Range
0
12345
9
0
When this option is selected, the scanner will be configured for Close Range Depth of Field and Short Range IR when operated in the stand.
12345
21610
7
When this option is selected, the scanner will be configured for Normal Depth of Field and Long Range IR when operated out of the stand. J-4
Page 157
Extended Depth of Field out of Stand IR Long Range
0
12345
21600
Optional Depth of Field out of Stand IR Lon Range
8 0
When this option is selected, the scanner will be configured for Extended Depth of Field and Long Range IR when operated out of the stand.
12345
21620
21630
5
Do not scan this bar code unless instructed to do so by a Metrologic representative.
Close Depth of Field out of Stand IR Short Range
0
12345
6
When this option is selected, the scanner will be configured for Close Depth of Field and Short Range IR when operated out of the stand. J-5
Page 158
MS6720 with 4680 IO Processor This unit converts decoded bar code data to an IBM 468X/469X operating system compatible data format. It supports IBM 1520/Port 5b, IBM 4500/Port 9b CCD, and IBM 3687-2/Port 17 emulations. To implement this mode, power the terminal down and then up between scanner configuration sequences to make sure the auto-sensing device drivers for some IBM 468X and 469X SIOC platforms are correctly initialized.
Configure the unit for 4680 communications by scanning Enter/Exit Program Mode, Load Defaults, Enable IBM 4680 Communication, select the emulation mode from page J-7 and Enter/Exit Program Mode bar codes. Reference page B-1 of this guide to find the Enable IBM 4680 Communication bar code. NOTE: IBM 468X/469X systems will look for the UPC-E version “0" number system digit and check digit being transmitted. These digits are automatically turned on when the 4680 interface is enabled. These differ from standard defaults.
J-6
Page 159
IBM 468x RS-485 SIOC Scanner Emulations
IBM 4500 CCD Emulation
These bar codes allow the user to select various IBM serial input/output channel (SIOC) scanner/part emulation modes for scanners equipped with the IBM RS-485 interface. 0
12345
31770
5
Scan this bar code to select IBM 4500 CCD emulation for scanners equipped with the IBM RS-485 interface.
IBM 3687-2 Emulation
IBM 1520 Emulation
0
12345
31760
0
6
12345
31750
7
Scan this bar code to select IBM 3687-2 emulation for scanners equipped with the IBM RS-485 interface.
Scan this bar code to select IBM 1520 emulation for scanners equipped with the IBM RS-485 interface. J-7
Page 160
Reserved
MS6720 - Light Pen/Wand Emulation Units
This option should not be enabled without written instructions from Metrologic.
Beginning with the MS6720 revision D scanners, the speed at which Light Pen/Wand data can be transmitted is user selectable. The user can first set the border size to 10x or 50x then select the specific “x” or narrow element size used by the scanner to send data. Refer to the bar codes on the following pages for selection options.
Reserved
10x Border
0
0
12345
12345
31740
31730
8
0
9
This option should not be enabled without written instructions from Metrologic.
J-8
12345 11702 2 This bar code allows the transmission of Light Pen/Wand emulation using a 10x border. For a specific scalable narrow element, select a bar code from page J - 9 or J - 10.