For the Metrologic MS6720

Page 151

Function keys F1 - F12 and other keys (No E0H required) KEY

AT SCAN CODE

XT/PS2 SCAN CODE

CODE BYTE

3BH

PREFIX/SUFFIX VALUE HEX DECIMAL 90H = 144

F1

05H

F2

06H

3CH

91H = 145

F3

017

04H

3DH

92H = 146

018

F4

0CH

3EH

93H = 147

019

F5

03H

3FH

94H = 148

020

F6

0BH

40H

95H = 149

021

F7

83H

41H

96H = 150

022

F8

0AH

42H

97H = 151

023

F9

01H

43H

98H = 152

024

F10

09H

44H

99H = 153

025

F11

78H

57H

9AH = 154

026

016

F12

07H

58H

9BH = 155

027

NUMERIC +

79H

4EH

9CH = 156

028

NUMERIC -

7BH

4AH

9DH = 157

029

NUMERIC *

7CH

37H

9EH = 158

030

CAPS LOCK

58H

3AH

9FH = 159

031

NUM LOCK

77H

45H

A0H = 160

032

LEFT ALT KEY

11H

38H

A1H = 161

033

LEFT CTRL KEY

14H

1DH

A2H = 162

034

LEFT SHIFT

12H

2AH

A3H = 163

035

RIGHT SHIFT

59H

36H

A4H = 164

036

I - 36

Page 152

Section J 6720 Specific Codes All of the options in this section are available with the 6720 scanner. Projection vs Hand Held Scanner Modes and IR Sensor Hand Held Scanner Operation Mode *Scanner Projection Mode *10 Minutes IR Time-outs - Projection 5 Second Laser Off - Hand Held 2 Minutes IR Time-outs - Projection 2 Second Laser Off - Hand Held 30 Minutes IR Time-outs 10 Second Laser Off - Hand Held No IR Time-outs - Projection and Hand Held Depth of Field /IR Range Sensor Switch *Normal DOF in the Stand IR Long Range Extended DOF in the Stand IR Long Range Close DOF in the Stand IR Short Range Optional DOF in the Stand IR Long Range *Normal DOF out of Stand IR Long Range Extended DOF out of Stand IR Long Range

DOF = Depth of Field (J - 1) (J - 2) (J - 2) (J - 2) (J - 2) (J - 3) (J - 3) (J - 3) (J - 3) (J - 4) (J - 4) (J - 4) (J - 4) (J - 5)

J-i

Close DOF out of Stand IR Short Range Optional DOF out of Stand IR Long Range MS6720 with 4680 IO Processor IBM 468x RS-485 SIOC Scanner Emulation IBM 1520 Emulation IBM 4500 CCD Emulation IBM 3687-2 Emulation MS6720 - Light Pen/Wand Emulation Units 10x Border *50x Border .15ms Narrow Element 0.3ms Narrow Element 0.5ms Narrow Element 1.0ms Narrow Element

(J - 5) (J - 5) (J - 6) (J - 7) (J - 7) (J - 7) (J - 7) (J - 8) (J - 8) (J - 9) (J - 9) (J - 9) (J - 9) (J - 10)

Page 153

Projection vs Hand Held Scanner - Modes and IR Sensor When the Projection Scanner (default) Mode bar code is chosen the scanner will behave like an MS700. The IR sensor is used to “wake” the scanner up for an extended period of time. These bar codes have the following features: Bar Code 10 min IR Timeout 2 min IR Timeout 30 min IR Timeout No IR Timeout

Laser Off/Motor Off 10 mins 2 mins 30 mins Always On

When the Hand Held Scanner Operation Mode bar code is chosen, the scanner will behave like an MS951. It will look for data only after the IR sensor has been activated. These bar codes have the following features: Bar Code

Laser Off

10 min IR Timeout 2 min IR Timeout 30 min IR Timeout No IR Timeout

5 secs 2 secs 10 secs Always On

J-1

Page 154

Hand Held Scanner Operation Mode

0

12345

11311

*10 Minutes IR Time-outs - Projection 5 Second Laser Off - Hand Held

6 0

When this option is chosen, the scanner will behave like an MS951. It will look for data in response to an IR sensor activation.

12345

11301

20930

7

This time represents the duration of time of inactivity from the last scan until the scanner enters a “standby” mode. The scanner will not return to scanning until an object is waved in front of the IR sensor.

2 Minutes IR Time-outs - Projection 2 Second Laser Off - Hand Held

*Scanner Projection Mode

0

12345

7

0

When this option is chosen, the scanner will behave like an MS700. It will look for bar code data as long as the scanner is awake, regardless of the IR sensor status.

12345

20920

8

This time represents the duration of time of inactivity from the last scan until the scanner enters a “standby” mode. The scanner will not return to scanning until an object is waved in front of the IR sensor. J-2

Page 155

30 Minutes IR Time-outs - Projection 10 Second Laser Off - Hand held

0

12345

20910

Depth of Field/IR Range Sensor Switch The scanning process can be initiated by an infrared (IR) device that is below the output window. The depth of field for the scanner is 0"8". The following bar codes are 8 combinations of the Depth of Field/IR Activation operations currently available. With these bar codes, the scanner can:

9

This time represents the duration of time of inactivity from the last scan until the scanner enters a “standby” mode. The scanner will not return to scanning an object is waved in front of the IR sensor.

a.) sense when it is in or out of the stand b.) adjust the scanning depth of field c.) adjust the depth of field in which the IR sensor activates

*Normal Depth of Field in the Stand IR Long Range

No IR Time-outs - Projection and Hand Held

0

12345

20900

0

0

12345

23100

1

When this option is selected, the scanner will be configured for Normal Depth of Field and Long Range IR when operated in the stand.

When this option is chosen, the scanner will not enter a “standby” mode. When using a Tech scanner, select this option since these units do not have an IR sensor or a touchplate. J-3

Page 156

Extended Depth of Field in the Stand IR Long Range

0

12345

23110

Optional Depth of Field in the Stand IR Long Range

0 0

When this option is selected, the scanner will be configured for Extended Depth of Field and Long Range IR when operated in the stand.

12345

23120

23130

8

Do not scan this bar code unless instructed to do so by a Metrologic representative.

*Normal Depth of Field out of Stand IR Long Range

Close Depth of Field in the Stand IR Short Range

0

12345

9

0

When this option is selected, the scanner will be configured for Close Range Depth of Field and Short Range IR when operated in the stand.

12345

21610

7

When this option is selected, the scanner will be configured for Normal Depth of Field and Long Range IR when operated out of the stand. J-4

Page 157

Extended Depth of Field out of Stand IR Long Range

0

12345

21600

Optional Depth of Field out of Stand IR Lon Range

8 0

When this option is selected, the scanner will be configured for Extended Depth of Field and Long Range IR when operated out of the stand.

12345

21620

21630

5

Do not scan this bar code unless instructed to do so by a Metrologic representative.

Close Depth of Field out of Stand IR Short Range

0

12345

6

When this option is selected, the scanner will be configured for Close Depth of Field and Short Range IR when operated out of the stand. J-5

Page 158

MS6720 with 4680 IO Processor This unit converts decoded bar code data to an IBM 468X/469X operating system compatible data format. It supports IBM 1520/Port 5b, IBM 4500/Port 9b CCD, and IBM 3687-2/Port 17 emulations. To implement this mode, power the terminal down and then up between scanner configuration sequences to make sure the auto-sensing device drivers for some IBM 468X and 469X SIOC platforms are correctly initialized.

Configure the unit for 4680 communications by scanning Enter/Exit Program Mode, Load Defaults, Enable IBM 4680 Communication, select the emulation mode from page J-7 and Enter/Exit Program Mode bar codes. Reference page B-1 of this guide to find the Enable IBM 4680 Communication bar code. NOTE: IBM 468X/469X systems will look for the UPC-E version “0" number system digit and check digit being transmitted. These digits are automatically turned on when the 4680 interface is enabled. These differ from standard defaults.

J-6

Page 159

IBM 468x RS-485 SIOC Scanner Emulations

IBM 4500 CCD Emulation

These bar codes allow the user to select various IBM serial input/output channel (SIOC) scanner/part emulation modes for scanners equipped with the IBM RS-485 interface. 0

12345

31770

5

Scan this bar code to select IBM 4500 CCD emulation for scanners equipped with the IBM RS-485 interface.

IBM 3687-2 Emulation

IBM 1520 Emulation

0

12345

31760

0

6

12345

31750

7

Scan this bar code to select IBM 3687-2 emulation for scanners equipped with the IBM RS-485 interface.

Scan this bar code to select IBM 1520 emulation for scanners equipped with the IBM RS-485 interface. J-7

Page 160

Reserved

MS6720 - Light Pen/Wand Emulation Units

This option should not be enabled without written instructions from Metrologic.

Beginning with the MS6720 revision D scanners, the speed at which Light Pen/Wand data can be transmitted is user selectable. The user can first set the border size to 10x or 50x then select the specific “x” or narrow element size used by the scanner to send data. Refer to the bar codes on the following pages for selection options.

Reserved

10x Border

0

0

12345

12345

31740

31730

8

0

9

This option should not be enabled without written instructions from Metrologic.

J-8