Page 21
³
1
0
1
0
0
0
* Enable 2 Digit Supplements with 37x, 43x, or UPC # System 5
³
1
0
1
0
1
0
Disable 2 Digit Supplements with 37x, 43x, or UPC # System 5
³
1
0
1
0
0
1
* Enable 5 Digit Supplements with 37x, 43x, or UPC # System 5
³
1
0
1
0
1
1
Disable 5 Digit Supplements with 37x, 43x, or UPC # System 5
³
1
0
0
3
1
5
³
1
0
0
3
0
5
³
1
0
1
4
1
1
³
1
0
1
4
0
1
³
1
0
1
4
1
4
³
1
0
1
4
0
4
³
3
0
1
3
4
0
400 msec to Find Supplemental – The scanner will allot 400 milliseconds to find an add on after a main UPC/EAN bar code has been scanned.
³
3
0
1
3
2
0
200 msec to Find Supplemental – The scanner will allot 200 milliseconds to find an add on after a main UPC/EAN bar code has been scanned.
³
3
0
1
3
1
0
* 100 msec to Find Supplemental – The scanner will allot 100 milliseconds to find an add on after a main UPC/EAN bar code has been scanned.
Enable Coupon Code 128 * Disable Coupon Code 128 Enable Code 128 ‘]C1’ Extended Code Format –The scanner transmits a ‘]C1’ at the beginning of the Code 128 portion of the coupon code. * Disable Code 128 ‘]C1’ Extended Code Format. * Enable Code 128 Group Separators – A “GS” (1DH) character will be transmitted with coupon Code 128 codes. Disable Code 128 Group Separators
3–3
Page 22
Enable Code ID’s with Supplements ³
1
0
1
2
1
4
³
1
0
1
2
0
4
³
1
1
8
4
0
6
³
1
1
8
4
1
6
³
1
0
1
3
1
5
³
1
0
1
3
0
5
³
1
0
1
3
1
7
³
1
0
1
3
0
7
³
1
0
1
3
1
6
³
1
0
1
3
0
6
³
1
2
5
1
1
5
³
1
2
5
1
0
5
³
1
2
5
1
0
6
³
1
2
5
1
1
6
* Disable Code ID’s with Supplements * Beep Once on Supplements Beep Twice on Supplements Enable ISBN Check Digit Transmission – Not available with all models. Disable ISBN Check Digit Transmission Enable Bookland to ISBN Conversion – Not available with all models. * Disable Bookland to ISBN Conversion Enable ISBN Re-Formatting * Disable ISBN Re-Formatting Enable Bookland to ISBN 979 Conversion * Disable Bookland to ISBN 979 Conversion * Normal ISBN Re-Formatting 13 Digit ISBN Re-Formatting
3–4
Page 23
Disable Supplemental when CodeGate Button is Pressed – Available for MS9540 scanners only. Requires standard Code Gate be inactive in and out of stand.
³
1
0
1
2
1
0
³
1
0
1
2
0
0
* CodeGate Does Not Affect Supplemental Scanning – Available for MS9540 scanners only.
³
1
2
5
0
1
7
No Supplement Checking if EAN-13 Code is just scanned
³
1
2
5
0
0
7
* Normal Supplement Checking
3–5
Page 24
3–6
Page 25
4 GS1 DataBar ®
®
Honeywell’s MS9520 Voyager and MS9540 VoyagerCG scanners with software #14810 and higher can be configured to scan GS1 DataBar type bar codes. ³
1
0
0
0
1
1
³
1
0
0
4
1
3
³
1
0
0
4
0
3
³
1
1
4
9
0
0
³
1
1
4
9
1
0
³
1
1
4
9
0
1
³
1
1
4
9
1
1
³
1
1
4
9
0
2
³
1
1
4
9
1
2
Double Border Required – Due to the large spaces commonly found in GS1 DataBar symbologies, Honeywell recommends double border requirements be enabled when scanning GS1 DataBar code type symbologies. Enable GS1 DataBar 14
* Disable GS1 DataBar 14
* Transmit GS1 DataBar 14 Check Digit
Do Not Transmit GS1 DataBar 14 Check Digit
* Transmit GS1 DataBar 14 Application ID –
Application Identifier “01” is transmitted by default. Do Not Transmit GS1 DataBar 14 Application ID
* Transmit GS1 DataBar 14 Symbology ID – Symbology Identifier “]e0” is transmitted by default. Do Not Transmit GS1 DataBar 14 Symbology
4–1
Page 26
GS1 DataBar Limited Enable GS1 DataBar Limited ³
1
0
0
4
1
4
³
1
0
0
4
0
4
³
1
1
4
9
0
3
³
1
1
4
9
1
3
³
1
1
4
9
0
4
³
1
1
4
9
1
4
³
1
1
4
9
0
5
³
1
1
4
9
1
5
* Disable GS1 DataBar Limited * Transmit GS1 DataBar Limited CD Do Not Transmit GS1 DataBar Limited CD * Transmit GS1 DataBar Limited Application ID – Application identifier “01” is transmitted by default. Do Not Transmit GS1 DataBar Limited Application ID * Transmit GS1 DataBar Limited Symbology ID – Symbology identifier “]e0” is transmitted by default. Do Not Transmit GS1 DataBar Limited Symbology ID
GS1 DataBar Expanded Enable GS1 DataBar Expanded ³
1
0
0
4
1
5
³
1
0
0
4
0
5
³
1
1
4
9
0
6
³
1
1
4
9
1
6
* Disable GS1 DataBar Expanded
4–2
* Transmit GS1 DataBar Expanded Symbol ID – Symbology identifier “]e0” is transmitted by default. Do Not Transmit GS1 DataBar Expanded Symbol ID
Page 27
5 ISBT Code 128 Implementation Configuration Mode ³
1
3
8
4
1
7
³
1
3
8
4
0
7
Enable ISBT Code 128 Disable ISBT Code 128
The bar codes below enable or disable a special transmit mode as outlined in section 3.5.2 of the ISBT-128 Specification. This output method allows the user to confirm independently the accuracy of the Code-128 check digit. ³
1
3
8
4
1
6
³
1
3
8
4
0
6
Enable ISBT Special Transmit Disable ISBT Special Transmit
The bar codes below enable or disable the transmission of the ISBT Code 128 data identifiers. When this option is enabled, the first two data characters are removed from the data stream (ID characters) unless the ISBT bar code scanned contains Donation Identification Number identifiers. If Donation Identification Number identifiers are present, only the first ID character is removed from the Donation ID Number. The second is regarded as normal data. ³
1
3
8
4
1
5
³
1
3
8
4
0
5
Don’t Transmit ISBT ID’s * Transmit ISBT Identifiers
The bar codes below convert and transmit the Mode 37, 2 check digit from the flag digits of the Donation Identification Number provided the check digit is contained in the flag digits. Transmission of the Donation Identification number will be the same except for the last two digits, which are converted into a single check sum character. ³
1
3
8
5
1
0
³
1
3
8
5
0
0
Convert Flag Digits to Mod 37, 2 CD * Normal Flag Digit Transmission
5–1
Page 28
Concatenation Configuration Mode
†
The following bar codes are used to configure variable time requirements used to find the second bar code of the ISBT concatenation sequence. ³
3
0
1
3
1
0
³
3
0
1
3
2
0
³
3
0
1
3
3
0
³
3
0
1
3
4
0
³
3
0
1
3
5
0
³
3
0
1
3
6
0
³
3
0
1
3
7
0
100 msec to Find Concatenation Sequence 200 msec to Find Concatenation Sequence 300 msec to Find Concatenation Sequence 400 msec to Find Concatenation Sequence 500 msec to Find Concatenation Sequence 600 msec to Find Concatenation, Sequence 700 msec to Find Concatenation Sequence
Pre-Defined Concatenation Configuration Mode † The first two bar codes below enable or disable pre-defined concatenation sequences. The remaining bar codes enable the specific pre-defined concatenation sequence shown, but are not needed to enable concatenation. They can be used to disable or re-enable any selected pre-defined concatenation sequence. ³
1
3
8
4
1
3
³
1
3
8
4
0
3
³
4
3
8
4
8
0
Enable Pre-Defined Concatenation Sequence Disable Pre-Defined Concatenation Sequence Donation Identification Number + AB0/Rh (D) Blood Groups =á + =% Concatenation
† This feature is only supported in the MS9500 Voyager product series.
5–2
Page 29
Donation Identification Number + Donor Identification Number =á + &; Concatenation
³
4
3
8
4
9
0
³
4
3
8
4
1
0
0
Donation Identification Number + Confidential Unit Exclusion Status =á + &! Concatenation
³
4
3
8
4
1
1
0
Product Code + Expiration Date (Form 1) =< + =>Concatenation
³
4
3
8
4
1
2
0
Product Code + Expiration Date (Form 2) =< + &> Concatenation
³
4
3
8
4
1
3
0
Product Code + Expiration Date (Form 3) &< + => Concatenation
³
4
3
8
4
1
4
0
Product Code + Expiration Date (Form 4) &< + &> Concatenation
User-Defined Concatenation Configuration Mode The first two bar codes shown below can be used to enable or disable userdefined concatenation sequences. The remaining bar codes are used to enter the user-defined identifiers used in the concatenation sequence. First enter configuration mode then scan the one of the identifier codes, followed by the code byte sequence or the desired identifiers. ³
1
3
8
4
1
4
³
1
3
8
4
0
4
³
9
3
8
0
0
0
³
9
3
8
1
0
0
³
9
3
8
2
0
0
³
9
3
8
3
0
0
Enable User-Defined Sequences Disable User-Defined Sequences st
1 Left Identifier 2 nd
Left Identifier st
1 Right Identifier 2 nd
Right Identifier
† This feature is only supported in the MS9500 Voyager product series.
5–3
Page 30
The following example demonstrates how to configure the User-Defined ISBT identifiers: Assume the left-hand identifiers are the ISBT defined donation identification number: “=G”; and the right hand identifiers are country specific identifiers “&a”. 1. Scan the ENTER/EXIT configuration mode bar code. st 2. Scan the 1 Left Identifier configuration mode bar code. 3. Scan (Code Byte 0) + (Code Byte 6) + (Code Byte 1). nd 4. Scan the 2 Left Identifier configuration mode bar code. 5. Scan (Code Byte 0) + (Code Byte 7) + (Code Byte 1). st 6. Scan the 1 Right Identifier configuration mode bar code. 7. Scan (Code Byte 0) + (Code Byte 3) + (Code Byte 8). nd 8. Scan the 2 Right Identifier configuration mode bar code. 9. Scan (Code Byte 0) + (Code Byte 9) + (Code Byte 7). 10. Scan the Enable User-Defined Sequence bar Code. 11. Scan the Enable ISBT bar code. 12. Scan the ENTER/EXIT configuration mode bar code. The scanner is now configured with the appropriate identifiers. Since both ISBT and User-defined Concatenation are enabled, ISBT 128 bar codes scanned successively that contain these identifiers will be concatenated. An alternate method of the type found in section 4.8.1 of the ISBT specifications can be used for configuring user-defined concatenation sequences. Using the previous example, the identifiers can be configured into a single configuration mode bar code. The following bar codes can be used to enable and disable the user-defined concatenation. Enable (Left, =G) + (Right, &a)
=
&
³
=
G
& a
5
0
5 d
1
Disable (Left, =G) + (Right, &a)
=
&
³
=
G
& a
5
0
5 d
0
Note: These configuration bar codes require Single-Code configuration mode. These bar codes are not recognized in Multi-Code configuration mode. Two forms of concatenation can be enabled at any given time, one pre-defined sequence and the user-defined sequence. Code selects and ISBT Code-128 concatenation cannot be used simultaneously. Both functions use the same internal resources so they must remain mutually exclusive.
5–4