21 IS4125 and IS4225 Scan Engines Disable Old Serial Program ³
1
2
0
3
1
5
³
1
2
0
3
0
5
³
1
2
0
3
1
1
³
1
2
0
3
1
2
³
1
2
0
3
1
3
³
8
0
1
1
³
9
9
9
8
Enable Old Serial Program
Enable TTL UART
Enable Non Buffered TTL UART
Enable Detect and Notify Mode
4
6
6
0
Cunningham Defaults – Scan this code followed by Recall Defaults code to enable and load Cunningham defaults. Recall Defaults
9
9
For Same Symbol Time Out information, see page 7–3.
21–1
Page 102
21–2
Page 103
22 IS4823 and IS4825 Scan Engines Operating Modes Activation Modes ³
4
1
8
3
0
4
³
1
1
8
1
1
0
³
1
2
0
3
1
6
³
1
1
7
4
1
5
³
9
1
7
5
0
0
* Activate Scanning with the External Trigger – An external I/O pin is used to enable the scanning cycle. A High-to-Low transition on the I/O signal is used to activate scanning. The signal must be deactivated (HIGH) and re-activated for subsequent scanning cycles. The scanning cycle is terminated based on the default period of time (2 seconds), a variable period of time, when the I/O signal is deactivated (Low-to-High), or when a bar code is scanned and transmitted. Activate Scanning on Receipt of the <DC2> Character – A received <DC2> character initiates the scanning cycle. The scanning cycle is terminated based on the default period of time (2 seconds), variable laser timeout selected, or when a bar code is scanned and transmitted. Activate Scanning Using D/E – A received ‘E’ character initiates the scanning cycle. The scanning cycle is terminated based on the default period of time (2 seconds), variable laser timeout selected, or receipt of a ‘D’ or when a bar code is scanned and transmitted. Activate Scanning with Address – A configurable address character is used to initiate scanning. The scanning cycle is terminated based on the default period of time (2 seconds), variable laser timeout selected, or when a bar code is scanned and transmitted. ~ Address Value – Use this bar code with a code byte sequence (on page 16–1) that represents the desired character to be used to initiate scanning. An ASCII reference table is available on page 16–3.
22–1
Page 104
Activation Mode Features ~ Variable Laser-On Time Out – Scan this bar code with a code byte sequence (on page 16–1) that represents the desired time out increment. The configurable time increment (1-second increments) selected is the scanning laser-on time.
³
9
1
9
6
0
0
³
1
2
0
3
1
4
Allow Full Laser-On Cycle – The laser stays on for a full cycle even when a bar code is scanned and transmitted.
³
4
1
8
3
2
4
Blinky Mode – The laser turns on after the selected activation trigger is detected. The laser will blink on/off for approximately 30 seconds.
³
1
1
8
1
1
1
³
1
1
8
1
0
1
³
1
1
8
3
1
1
³
1
1
8
3
0
1
³
1
1
9
9
1
7
³
1
2
0
3
0
3
Transmit a NO READ Message on Laser Time Out – If the scanning cycle terminates without scanning a bar code during the cycle, a NO READ message is transmitted with the termination of the scanning cycle. Do Not Transmit a NO READ Message on Laser Time Out Activate the LED during the NO READ Transmission – The LED is output with the NO READ message. Deactivate LED during the NO READ Transmission
Enable RTS No Read Pulse – A configurable RTS pulse width transmitted after the NO READ message has been transmitted. Disable RTS No Read Pulse
22–2
Page 105
³
1
2
0
3
1
3
Detect and Notify Mode (Monitor the External Trigger) – The external I/O pin used in the default activation mode is monitored during the inactive laser cycles. An <SI> is transmitted when the I/O is active and an <SO> when it is inactive. Once the scanning activation cycle is started, the external I/O monitoring status is maintained until the scanning cycle is terminated regardless of the actual I/O level.
Continuous Blinky Mode ³
4
1
8
3
3
4
0
0
Continuous Blinky Mode – The scanner will continuously blink on and off, turning the scanning cycle on and off for all normal scanner operations. If a bar code is scanned and transmitted, the same symbol timeout is maintained throughout the cycle preventing additional scans of the same bar code when the scanner is in default mode.
Sleep Mode ³
9
1
9
5
~ Sleep Mode – A power saving mode that can be configured to occur in 1-second increments. Use this code with a code byte sequence (on page 16–1) that represents the desired increment.
22–3
Page 106
22–4
Page 107
23 Miscellaneous Features Custom Defaults Honeywell manufactures several scanners for OEM applications. These scanners may use a different set of defaults than Honeywell factory defaults. Scanning the bar code will reset the default table to Honeywell defaults. Enable Factory Defaults – Scan this code followed by Recall Defaults code to enable and load Honeywell factory defaults.
³
8
4
6
6
0
0
³
9
9
9
9
9
8
³
8
4
6
6
1
2
8
0
³
8
4
6
6
0
0
1
0
RCH – Scan this code followed by Recall Defaults code to enable and load RCH defaults.
³
8
4
6
6
0
0
2
0
Sanyo – Scan this code followed by Recall Defaults code to enable and load Sanyo defaults.
³
8
4
6
6
0
0
3
0
Gilbarco – Scan this code followed by Recall Defaults code to enable and load Gilbarco defaults.
³
8
4
6
6
0
0
4
0
ALT Defaults – Scan this code followed by Recall Defaults code to enable and load Alt defaults.
³
8
4
6
6
0
0
5
0
LaCaixa Custom Keyboard Defaults – Scan this code followed by Recall Defaults code to enable and load LaCaixa defaults.
³
8
4
6
6
0
1
2
0
ABACAB Defaults – Scan this code followed by Recall Defaults code to enable and load ABACAB defaults.
Recall Defaults Ruby Verifone Defaults – Scan this code followed by Recall Defaults code to enable and load Ruby Verifone defaults.
23–1
Page 108
Serial Program Mode For Serial Program Mode, all commands must be framed by an STX (02 Hex) and ETX (03 Hex). To recall defaults: 1.
Transmit <STX>999999<ETX> through the Serial Port. This will put the scanner in serial program mode. Scanning will be suspended and the scanner will respond with an ACK (06 Hex).
2.
Transmit <STX>999998<ETX> through the Serial Port. This is the Recall Defaults bar code in the MetroSelect guide. The scanner will respond with an ACK (06 Hex).
3.
Transmit <STX>999999<ETX> through the Serial Port. This will cause the scanner to exit program mode and save the new settings. The scanner will beep 3 times and send an ACK (06 Hex).
If at anytime, the scanner cannot recognize a command, it will respond with a NAK (15 Hex).
23–2
Page 109
24 Customer Support Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nearest technical support office: North America/Canada Telephone: (800) 782-4263 E-mail: hsmnasupport@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 E-mail: hsmlasupport@honeywell.com Brazil Telephone: +55 (11) 5185-8222 Fax: +55 (11) 5185-8225 E-mail: brsuporte@honeywell.com Mexico Telephone: 01-800-HONEYWELL (01-800-466-3993) E-mail: soporte.hsm@honeywell.com Europe, Middle East, and Africa Telephone: +31 (0) 40 7999 393 Fax: +31 (0) 40 2425 672 E-mail: hsmeurosupport@honeywell.com Hong Kong Telephone: +852-29536436 Fax: +852-2511-3557 E-mail: aptechsupport@honeywell.com Singapore Telephone: +65-6842-7155 Fax: +65-6842-7166 E-mail: aptechsupport@honeywell.com China Telephone: +86 800 828 2803 Fax: +86-512-6762-2560 E-mail: aptechsupport@honeywell.com Japan Telephone: +81-3-3839-8511 Fax: +81-3-3839-8519 E-mail: aptechsupport@honeywell.com Online Technical Assistance You can also access technical assistance online at www.honeywellaidc.com. 24–1
Page 110
Product Service and Repair Honeywell International Inc. provides service for all its products through service centers throughout the world. To obtain warranty or non-warranty service, contact the appropriate location below to obtain a Return Material Authorization number (RMA #) before returning the product. North America Telephone: (800) 782-4263 E-mail: hsmnaservice@honeywell.com Latin America Telephone: (803) 835-8000 Telephone: (800) 782-4263 Fax: (239) 263-9689 E-mail: laservice@honeywell.com Brazil Telephone: +55 (11) 5185-8222 Fax: +55 (11) 5185-8225 E-mail: brservice@honeywell.com Mexico Telephone: 01-800-HONEYWELL (01-800-466-3993) Fax: +52 (55) 5531-3672 E-mail: mxservice@honeywell.com Europe, Middle East, and Africa Telephone: +31 (0) 40 2901 633 Fax: +31 (0) 40 2901 631 E-mail: euroservice@honeywell.com Hong Kong Telephone: +852-29536436 Fax: +852-2511-3557 E-mail: apservice@honeywell.com Singapore Telephone: +65-6842-7155 Fax: +65-6842-7166 E-mail: apservice@honeywell.com China Telephone: +86 800 828 2803 Fax: +86-512-6762-2560 E-mail: apservice@honeywell.com Japan Telephone: +81-3-3839-8511 Fax: +81-3-3839-8519 E-mail: apservice@honeywell.com
24–2