Page 19
Scan Field The depth of field for the scanner is from the face of the output window to five (5) inches (Refer to Figure 4). If the scanner is in the stand, a bar code must be presented to the scanner. When holding the scanner, position the output window within five inches of the bar code.
Figure 4
16
Page 20
Depth of Field and Symbol Specification (Refer to Figure 5) Code Type
Minimum Small Element Mil. (1/1000")
Code Density
*Depth of Field
UPC/EAN UPC/EAN Code 39 Code 39 Code 39 I 2 of 5 I 2 of 5 I 2 of 5 Codabar Codabar Codabar Code 93 Code 93 Code 128 Code 128
10.4 13.0 7.5 12.0 21.0 7.5 12.0 21.0 7.5 12.0 21.0 10.4 13.0 10.4 13.0
80% 100% High Medium Low High Medium Low High Medium Low 80% 100% 80% 100%
0" - 4" 0" - 5" 0" - 3" 1" - 5" 1" - 8" 0" - 3" 0" - 5" 1" - 8" 0" - 3" 0" - 5" 1" - 8" 0" - 4" 0" - 5" 0" - 4" 0" - 5"
Subject to change. *Decoder/controller dependent.
17
Page 21
18
MINIMUM ( 021
BAR WIDTH {
012
- WIDTH OF
0.0 SCAN FIELD
L (INCHES)
MINIMUM BAR WIDTH
00 10 20 30 40 50 60 70 80 DISTANCE: SCANNER FACE TO BAR CODE (INCHES)
Figure 5
Page 22
Maintenance Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. Gently wipe the scanner window.
19
Page 23
Appendix A Specifications Application: Light Source: CDRH: IEC: UL/CSA/TUV: EMI:
Hand-Held Laser Scanner VLD 675 ± 5nm Registered with CDRH, Class II laser product Maximum radiant power less than 1 mW IEC 825 Class I laser product Maximum radiant power less than 0.5 mW UL Listed, UL114; CSA certified, C22.2 No. 950, UL 1950 (1989); ] Complies with FCC & VDE Class A
Mechanical
Dimensions: Weight: Cable Length:
205mmL x 63mmW x 24mmD (8"L x 2.5"W x .94"D) .18 kg. (6.4 oz.) without cable Coil cord collapsed - 3.5'; Extended - 6'
Electrical
Power (Watts): Input Voltage, DC: Operating Current: Standby Current:
20
0.5 5V .100 Amps .025 Amps
Page 24
Operational
Depth of Field, UPC 100%: Scan Speed: Scan Pattern: Maintenance Required: Print Contrast: Roll, Pitch, Yaw:
Up to 125mm (5") from face 38 scan lines per second Single scan line Clean output window periodically 35% minimum reflectance difference 42E, 68E, 52E
The following operations are decoder/controller dependent. Beeper Operation: Decode Capability: Indicators:
Beeps on “Decode” or “Good Read” Decode controlled by MC941 decoder/controller or host system LED: red = laser on, ready to scan green = good read, decoding
Specifications subject to change without notice. U.S. Patent D31590; 5,340,971; 5,340,973 and 5,260,553 Environmental
Storage Temperature: Operating Temperature: Humidity: Light Levels: Ventilation: Shock: ESD: Contaminants:
-40EC to 60EC (-40EF to 140EF) 0EC to 35EC (32EF to 95EF) 5% to 95% relative humidity, non-condensing Up to 3200 foot candles; works in direct sunlight None required Drop of 1.5 meters (5') 8 kV IEC 801-2 Sealed to resist airborne particulate contaminants
21
Page 25
Appendix B MH941 Scan Head Pin Assignments
Pin
Signal Name
1
Flip Sense
Function
A square wave output signal that changes polarity when the scan mirror drive circuit changes the motor direction. The frequency is approximately 19 Hz to achieve a nominal 38 flips/scan per second. Note:
The polarity and mirror direction do not necessarily change at the same time.
This is an open collector output capable of sinking 25 mA via an external pull up resistor connected to a voltage not to exceed +20 VDC. 2
Data
An output digital representation of the scanned bar code. A low level represents a bar and a high level represents a space. This is an open collector output capable of sinking 25 mA via an external pull up resistor connected to a voltage not to exceed +20 VDC.
3
Decode LED
The scan head is equipped with LED and beeper assemblies. A +5 VDC to 12 VDC input to the head at this pin will light the green LED and if oscillated at about 2 KHz, drive a beeper. This should be supplied with no more than 30mA of current. Typically, this is used to indicate a decode has occurred.
22
Page 26
4
Reserved
5
Proximity Detect
The proximity detect is a momentary grounding switch. The controlling computer should provide a +5±.25 VDC pull up which can be grounded when the proximity detect activates. This indicates that an object has moved within scanning rage. It is recommended that this signal be debounced for approximately 30 milliseconds. Note:
This scan head was not designed to have the laser enabled continuously as might be desired if the scanner was in a permanent mounting fixture.
6
Laser/Motor Control
A +5 VDC input to the head which is used to start the flipper motor and signal processor, and enable the visible laser diode (VLD). This can be a TTL level signal and requires less than 1 milliampere of current.
7
Ground
A power ground capable of handling a 500 milliampere load.
8
SHIELD
Cable shield to chassis ground (no load).
9
Scanner VCC
Primary laser diode/motor power input. +5 VDC should be present at this pin and capable of supplying up to 125 mA when enabled by the signal at pin 6.
23
Page 27
Appendix C Warranty and Disclaimer Limited Warranty Products manufactured by Metrologic have a 2-year limited warranty from date of manufacture. This warranty is limited to repair, replacement or refund at Metrologic’s discretion. Faulty equipment must be returned to the Metrologic facility in Blackwood, New Jersey or Puchheim, Germany. To do this, contact Metrologic Customer Service/Repair for a Returned Material Authorization (RMA) number.
In the event that it is determined that the equipment failure is covered under the warranty, Metrologic shall, as its sole option, repair, replace with a functionally equivalent unit, or refund an amount equal to the purchase price to the original purchaser, whether distributor, dealer/reseller, or retail consumer, and return the equipment to the customer without charge for service or return freight. This limited warranty does not extend to any Product which, in the sole judge-ment of Metrologic, has been subjected to misuse, neglect, improper installation or accident, nor does it extend to any Product which has been repaired or altered by anyone who is not a Metrologic authorized representative. THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, ARISING BY LAW, CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING, WITHOUT LIMITATION, ANY INJURY TO PROPERTY OR PERSON OR EFFECT ON BUSINESS OR PROFIT, AND IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. Metrologic Instruments, Inc. Customer Service Department 90 Coles Road 1-800-ID-METRO (1-800-436-3876) Blackwood, NJ 08012 TEL: 609-228-8100 FAX: 609-228-6673 Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany TEL: 49-89-89019-0 FAX: 49-89-89019-200