Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 4

MH941 Hand-Held Laser Scanner Installation and User's Guide, pages 1 to 9

Pages 1 to 9 of 33

The original document is the PDF (585 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic MH941

Page 1

METROLOGIC INSTRUMENTS, INC. MH941 Hand-Held Laser Scanner Installation and User’s Guide

MLPN 2183 Printed in USA October 1998

Page 2

Locations: USA Corporate Headquarters Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012 Customer Service: 1-800-ID-METRO Tel: 609-228-8100 Fax: 609-228-6673 info@metrologic.com www.metrologic.com

Europe Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany Tel: 49-89-89019-0 Fax: 49-89-89019-200 metrologic@europe.metrologic.com

ASIA Metrologic Asia (PTE) Ltd. 31, Kaki Bukit Road 3 #05-08 Techlink Singapore 417818 Tel: 65-842-7155 Fax: 65-842-7166 ant888@cyberway.com.sg

South America Metrologic Instruments Rua Flórida, 1.821-5°Andar-Brooklin CEP 04571-090, São Paulo-SP, Brasil Outside Brazil: Tel: 55-11-5505-6568 Fax: 55-11-5505-1681 info@sa.metrologic.com In Brazil: Tel: 55-11-5505-2396 Fax: 55-11-5507-2301 metrolog@br.metrologic.com Copyright

© 1998 by Metrologic® Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.

ii

Page 3

Table of Contents Introduction and Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Unpacking List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Connecting the MH941 Hand-Held Scanner to the Fixed Scanner and Host Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Connecting the MH941 Hand-Held Scanner to the Decoder/Controller . . . . 4 Parts of the MH941 Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Audible Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-9 Visual Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-13 Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 IR Sensor Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Scan Field . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Depth of Field and Symbol Specification . . . . . . . . . . . . . . . . . . . . . . . . 17, 18 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Appendix A

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20, 21 Appendix B

MH941 Scan Head Pin Assignments . . . . . . . . . . . . . . . . . . . . 22, 23 Appendix C

Warranty and Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 25 Appendix D

Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26, 27 Appendix E

Patents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29, 30 iii

Page 4

Introduction and Identification When using the MH941 scanner with a decoder not manufactured by Metrologic, scanner operation is dependent upon your decoder. Since there are many decoders available, refer to your decoder’s documentation concerning scanner requirements and operation. When using a Metrologic hand-held scanner with one of Metrologic’s fixed scanners, the scanner will operate as follows: !

The IR signal extends approximately eight (8) inches beyond the output window.

!

When the unit is activated by the IR sensor, the red LED will remain on. This is a visual indication that the scanner is beginning a sequence of bar code recognition, decoding, and transmission.

!

When an object is in the scan field, the laser will begin a sweep to determine if a bar code is present. If a bar code is not detected within approximately 2.5 seconds, the red LED will shut off indicating that the laser is no longer on. To reactivate the scanning sequence, remove the object and present another.

!

When a bar code is recognized, the scanner will decode the bar code and then transmit the data to the host system. When this occurs, the green LED will flash and the scanner will beep when the decoding is complete. At this time, the laser will turn off if the object is removed from the field. However, if the object stays in the field the laser will remain on for up to 2.5 seconds trying to detect another bar code. This feature allows very fast consecutive scans of symbols in close proximity, such as a wall of boxes or cartons, or bar coded menus. If the same symbol stays in the field after a successful scan, the laser will stay on for approximately 3.5 seconds and then turns off. This prevents unintentional reads of the same bar code. To read the same symbol more than once, simply remove the object from the scan field for approximately 1 second and then the scanner can scan the same symbol on the next pass.

1

Page 5

Unpacking List The following will be found in the shipping carton: !

Installation and User’s Guide

!

MH941 Hand-Held Laser Scanner

If anything is missing or to order additional items, contact your dealer, distributor or call Metrologic’s Customer Service Department.

2

Page 6

Connecting the MH941 Hand-Held Scanner to the Fixed Scanner and Host Device In order for the MH941 scanner to maintain compliance with applicable standards, all circuits connected to the scanner (Example: power supply, host system, etc.) must meet the requirements for SELV (Safety Extra Low Voltage) according to EN60950. 1. Make sure the host system is turned off. 2. Connect the head cable of the MH941 hand-held scanner to the cable terminated with a 9-pin connector attached to the fixed scanner. 3. There are two ways to connect the fixed scanner to the host device completely: ! If the fixed scanner will be powered by the host system, connect the communication cable to the host device. ! If the fixed scanner will be powered by an external power supply, the socket-outlet can be installed near the equipment and can be easily accessible. Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. Connect the scanner’s communication cable to the scanner. Connect the cable to the host device. Power up the scanner by plugging in the power supply. 4. Power up the host system. Note:

When the MH941 scanner first receives power, it will immediately go through a self diagnostic routine, then the green and red LEDs will flash, and the unit will beep once.

3

Page 7

Connecting the MH941 Hand-Held Scanner to the Decoder/Controller In order for the MH941 scanner to maintain compliance with applicable standards, all circuits connected to the scanner (Example: power supply, host system, etc.) must meet the requirements for SELV (Safety Extra Low Voltage) according to EN60950. Since there are many different types of decoders, refer to your decoder’s documentation to connect the decoder to your host system. For a listing of the cable pin assignments for the MH941 scanner, refer to the section MH941 Scan Head Pin Assignments pages 22 and 23.

Figure 1

4

Page 8

Parts of the MH941 Scanner Becoming familiar with the features of the MH941 scanner will help when operating the scanner. The following illustration and list explain the pertinent parts.

Figure 2

Laser Output Window

The laser beam emits from this aperture.

Head Cable

Ths cable is terminated with a 9-pin squeeze connector.

The following functions are decoder /controller dependent. Green LED

When the green light flashes on, the scanner has read the bar code successfully. When the green light turns off, communication to the host is complete.

Red LED

When the red light is on, the scanner is ready to scan.

ScanQuest™ Infrared Object Sensor

The scanner has an energy saving feature known as ScanQuest that senses when a specified time has elapsed without any scanning. If the unit remains dormant for this time, the laser and motor will turn off. In this stage, the scanner’s computer is on “stand by.” To reactivate the unit, wave an object in front of the IR (infrared) sensor or pick up the scanner and direct the scan window downwards. When the red light comes on, the scanner is ready to scan.

5

Page 9

Audible Indicators There are audible indications that signal the status of your scanner. These indications are dependent upon the decoder being used. The function of these indications may not work as described below if using a decoder not manufactured by Metrologic. When the scanner is in operation, it will provide warnings with audible indications. These sounds signal the status of the scan and scanner. One Beep

When the scanner first receives power, the red LED will blink, followed by the green LED, and then the scanner will emit one beep. After the scanner performs this startup sequence, the scanner is ready to scan. The green LED will flash and beep once when the unit successfully reads a bar code. If the green LED does not flash or the scanner does not beep once, then the bar code has not been successfully read.

Razzberry Tone

6

If, upon power up, the scanner emits a razzberry tone, then the scanner has failed diagnostics. Report this problem to the company where the scanner was purchased.