Page 71

SECTION D

HOST SCANNER COMMANDS

Enable “D/E” Disable Command

³

1

1

8

0

1

* Disable “D/E” Disable

5

³

1

1

8

0

The scanner will disable scanning after it receives and ASCII “D” from the host device. It will enable scanning when it receives an ASCII “E”.

Do not monitor D/E commands.

Enable “Z/R” Type D/E Simulation

* No “Z/R” Type D/E Simulation

³

1

1

8

2

1

1

³

The scanner will disable scanning after it receives an ASCII “Z” from the host device. It will enable scanning when it receives an ASCII “R”.

1

1

8

2

Do not monitor Z/R commands.

Scanner Operation

D

19

0

5

0

1

Page 72

Scanner Operation

SECTION D

D

20

HOST SCANNER COMMANDS

Enable “F/L” Laser Command

* Disable “F/L” Laser Command

³

³

1

1

8

0

1

4

1

1

8

0

0

The scanner will turn off the laser after receiving an ASCII “F” character. The laser will turn on after it receives an ASCII “L” character.

Do not monitor “F/L” commands.

Motor “On/Off” Using M/O Commands †

* Disable “M/O” Commands

4

† For use with omnidirectional scanners only.

³

1

1

8

2

1

3

The scanner will turn the motor OFF after it receives an ASCII “O” character. The motor will turn ON after the scanner receives an ASCII “M” character. †

³

1

1

8

2

0

3

Do not monitor the M/O commands.

Page 73

SECTION D

HOST SCANNER COMMANDS

Enable I Command

³

1

1

5

9

Disable I Command

1

7

³

Enable i Command

³

1

1

5

9

1

1

5

9

0

7

Disable i Command

1

6

³

1

1

5

9

0

6

Enable SI/SO Command

Disable SI/SO Command

³

³

1

2

5

0

1

4

Scanner Operation

D

21

1

2

5

0

0

4

Page 74

Scanner Operation

SECTION D

1

1

8

1

22

HOST SCANNER COMMANDS

Use DTR Scan Disable

³

D

* Do not use DTR Scan Disable

1

5

³

1

1

8

1

0

5

The scanner will monitor the DTR input to determine if scanning should be allowed. A +12V “active” level enables decoding. A -12V “inactive” level disables decoding.

Do not monitor the DTR input.

Enable Pass Through

Disable Pass Through

³

1

2

4

7

1

1

³

1

2

4

7

0

1

The AUX scanner must be configured for the same Baud rate as the host, with STX prefix, Nixdorf ID characters and CR Terminator enabled.

Activate on DC2 Character

* Do Not Activate on DC2 Character

³

³

1

1

8

1

1

0

1

1

8

1

0

0

Page 75

SECTION D

HOST SCANNER COMMANDS

Transmit “NO READ” if DC2 Activated

³

1

1

8

1

1

Do Not Transmit “NO READ” if DC2 Activated

1

³

No Green LED During “NO READ” Xmit

³

1

1

8

3

1

1

1

8

1

0

1

* Green LED During “NO READ” Xmit

1

³

Scanner Operation

D

23

1

1

8

3

0

1

Page 76

Scanner Operation

SECTION D

D

24

POWER SAVE MODES

Always Power Save Mode†

No Power Save Mode†

³

³

1

1

8

6

1

7

The scanner enters power save mode immediately after power-up and after each bar code scanned. †

8

1

8

6

0

0

The scanner will never enter power save mode. †

† For use with omnidirectional scanners only.

Power Save Mode in 2 minutes †

Power Save Mode in 1 minute †

³

1

1

8

6

1

0

The scanner enters power save mode when the scanner remains idle for 1 minute. †

³

8

1

8

6

2

0

The scanner enters power save mode if the scanner remains idle for 2 minutes. †

Page 77

SECTION D

POWER SAVE MODES

Power Save in 5 Minutes †

Power Save in 10 Minutes †

³

³

8

1

8

6

5

0

8

1

8

6

1

0

0

The scanner enters power save mode if the scanner remains idle for 10 minutes.

The scanner enters power save mode if the scanner remains idle for 5 minutes. †

†

† For use with omnidirectional scanners only.

Power Save in 20 Minutes †

Power Save in 30 Minutes†

³

³

8

1

8

6

2

0

0

The scanner enters power save mode if the scanner remains idle for 20 min. †

8

1

8

6

3

0

0

The scanner enters power save mode if the scanner remains idle for 30 min. †

Scanner Operation

D

25

Page 78

Scanner Operation

SECTION D

3

1

9

4

26

POWER SAVE MODES

Default Power Save Mode ††

³

D

0

††

0

For MS7600, MS7220, and MS7320 series scanners only.

Blink Power Save Mode ††

³

3

1

9

4

1

0

Blinks the laser OFF & ON after a programmed period of non-use. When the scanner recognizes a bar code it will exit the Blink mode.

Laser Motor OFF Power Save Mode ††

Laser OFF Power Save Mode ††

³

3

1

9

4

2

0

³

3

1

9

4

3

0

Turns the laser OFF after a programmed period of nonuse. ††

Turns the laser and motor OFF after a programmed period of non-use. ††

The MS7220 and MS7320 will “wake” when the MultiFunction Button is pressed.

The MS7220 and MS7320 will “wake” when the MultiFunction Button is pressed.

The MS7600 will “wake if the IR detects movement.

The MS7600 will “wake if the IR detects movement.

Page 79

SECTION D

POWER SAVE MODES

Dual #1 Power Save Mode ††

³

3

1

9

4

4

†† For MS7600, MS7220, and MS7320 series scanners only.

Dual #2 Power Save Mode ††

0

³

3

1

9

4

6

0

“Blinks” the laser OFF & ON after a programmed period of non-use then turns the laser and motor OFF at thirty-minute intervals.

Turns the laser OFF after a programmed period of nonuse then turns the motor OFF after thirty-minute intervals.

The MS7220 and MS7320 will “wake” when the MultiFunction Button is pressed.

The MS7220 and MS7320 will “wake” when the MultiFunction Button is pressed.

The MS7600 will “wake if the IR detects movement.

The MS7600 will “wake if the IR detects movement.

* Enable Power Save Switch

Disable Power Save Switch

³

1

1

9

7

0

0

³

1

1

9

7

1

0

For MS7220 and MS7320 scanners only.

For MS7220 and MS7320 scanners only.

* Enable Bar Code Absence Detection

Disable Bar Code Absence Detection

³

1

1

8

2

0

0

³

Scanner Operation

D

27

1

1

8

2

1

0

Page 80

Scanner Operation

SECTION D

D

28

JAPANESE DOUBLE FIELD SUPPORT

To support Japanese Double Field Bar Codes, first make sure you have your scanner programmed to the following settings. • Disable segmented decoding • Enable 2 scan buffers • Disable bar code absence detection • Enable normal code selects Then, scan the Enable Japan 2 Field bar code. Enable Japan 2 Field

³

1

2

4

7

1

* Disable Japan 2 Field

3

³

1

2

4

7

0

3

Next, select the matching bar codes that are used for double field symbols. Note that only UPC/EAN bar codes are allowed in double field mode. Select at least two characters for each bar code. The maximum is 4 upper and 4 lower bar codes. EXAMPLE To select 54 as the first two characters in the Upper Code pair 1: 1. Scan the Upper Code 1 Character 1 bar code (shown on page D-31) 2. Determine the correct Code Byte Value for the character 5 in 54 (Refer to Section M’s ASCII Reference Table on pages M-7 and M-8) a. Scan Code Byte 0 b. Scan Code Byte 5 c. Scan Code Byte 3 3. Scan the Upper Code 1 Character 2 bar code (shown on page D-31) 4. Determine the correct Code Byte Value for the character 4 in 54. a. Scan Code Byte 0 b. Scan Code Byte 5 c. Scan Code Byte 2 To select 18 as the first two characters in the Lower Code pair 1: 1. Scan the Lower Code 1 Character 1 bar code (shown on page D-31) 2. Determine the correct Code Byte Value for the character 1 in 18 (refer to Section M’s ASCII Reference Table) a. Scan Code Byte 0 b. Scan Code Byte 4 c. Scan Code Byte 9 3. Scan the Lower Code 1 Character 2 bar code (shown on page D-31) 4. Determine the correct Code Byte Value for the character 8 in 18. (Refer to Section M’s ASCII Reference Table on pages M-7 and M-8) a. Scan Code Byte 0 b. Scan Code Byte 5 c. Scan Code Byte 6