The text of a manual · part 17 of 19
MetroSelect Configuration Guide, pages 161 to 170
Pages 161 to 170 of 188
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Metrologic MK9520 / MS9520, Metrologic MS9535, Metrologic MS9590, Metrologic IS6520 and Metrologic MS5145
Page 161
SECTION M
EXTENDED KEY CODE REFERENCE TABLE AT SCAN CODE
PS2 SCAN CODE
3151
PREFIX/SUFFIX VALUE HEX = DECIMAL
Ï
75H
48H
63H
80H = 128
Ð
72H
50H
60H
81H = 129
Î
74H
4DH
6AH
82H = 130
Í
6BH
4BH
61H
83H = 131
Insert
70H
52H
67H
84H = 132
Delete
71H
53H
64H
85H = 133
Home
6CH
47H
6EH
86H = 134
End
69H
4FH
00H
87H = 135
Page Up
7DH
49H
00H
88H = 136
Page Down
7AH
51H
00H
89H = 137
Right Alt
11H
38H
00H
8AH = 138
Right Ctrl
14H
1DH
39H
8BH = 139
Reserved
00H
00H
00H
8CH = 140
Reserved
00H
00H
00H
8DH = 141
Numeric Keypad Enter
5AH
1CH
79H
8EH = 142
Numeric Keypad /
4AH
35H
00H
8FH = 143
F1
05H
3BH
07H
90H = 144
F2
06H
3CH
0FH
91H = 145
F3
04H
3DH
17H
92H = 146
F4
0CH
3EH
1FH
93H = 147
F5
03H
3FH
27H
94H = 148
F6
0BH
40H
2FH
95H = 149
F7
83H
41H
37H
96H = 150
F8
0AH
42H
3FH
97H = 151
F9
01H
43H
47H
98H = 152
KEY
Code Bytes
M
11
Page 162
Code Bytes
SECTION M
M
12
EXTENDED KEY CODE REFERENCE TABLE AT SCAN CODE
PS2 SCAN CODE
3151
PREFIX/SUFFIX VALUE HEX = DECIMAL
F10
09H
44H
4FH
99H = 153
F11
78H
57H
56H
9AH = 154
F12
07H
58H
5EH
9BH = 155
Numeric +
79H
4EH
00H
9CH = 156
Numeric -
7BH
4AH
7CH
9DH = 157
Numeric *
7CH
37H
00H
9EH = 158
Caps Lock
58H
3AH
14H
9FH = 159
Num Lock
77H
45H
00H
A0H = 160
Left ALT
11H
38H
00H
A1H = 161
Left CTRL
14H
1DH
11H
A2H = 162
Left Shift
12H
2AH
12H
A3H = 163
Right Shift
59H
36H
59H
A4H = 164
Print Screen
Multiple
00H
00H
A5H = 165
Tab
0DH
0FH
0DH
A6H = 166
Shift Tab
8DH
8FH
65H
A7H = 167
Enter
5AH
1CH
5AH
A8H = 168
ESC
76H
01H
08H
A9H = 169
Left ALT Make
11H
36H
00H
AAH = 170
Left ALT Break
11H
B6H
00H
ABH = 171
Left CTRL Make
14H
1DH
00H
ACH = 172
Left CTRL Break
14H
9DH
00H
ADH = 173
11H
36H
00H
AEH = 174
14H
1DH
00H
AFH = 175
KEY
* Left ALT + 1 character * Left CTRL + 1 character * Example:
1st Configurable Prefix = 174 nd 2 Configurable Prefix = 065 Scanner will transmit <left ALT Make> “A” <Left ALT Break>
Page 163
SECTION N
CUSTOM DEFAULTS
Metrologic manufactures several scanners for OEM applications. These scanners may use a different set of defaults than the standard Metrologic factory defaults. Scanning the following bar codes will restore the default factory settings. Enable Factory Defaults
³
8
4
6
6
0
0
Scan this code followed by the “Recall Defaults” code to enable and load Metrologic factory defaults.
Recall Defaults
³
9
9
9
9
9
8
Miscellaneous Features
N
1
Page 164
Miscellaneous Features
2
N
SECTION N
CUSTOM DEFAULTS
Ruby Verifone Defaults
RCH
³
³
8 4 6 6 1 2 8 0
8
4
6
6
1
0
Scan this code followed by the “Recall Defaults” code to enable and load Ruby Verifone Defaults.
Scan this code followed by the “Recall Defaults” code to enable and load RCH Defaults.
Sanyo
Gilbarco
³
8
4
6
6
0
2
0
³
8
4
6
6
3
0
Scan this code followed by the “Recall Defaults” code to enable and load Sanyo Defaults.
Scan this code followed by the “Recall Defaults” code to enable and load Gilbarco Defaults.
ALT Defaults
MS6750 Defaults
³
³
8 4 6 6 0 0 4 0
Scan this code followed by the “Recall Defaults” code to enable and load ALT Defaults.
8 4 6 6 0 0 8 0
Scan this code followed by the “Recall Defaults” code to enable and load MS6750 Defaults.
Page 165
SECTION N
CUSTOM DEFAULTS/SERIAL PROGRAM MODE
Custom Keyboard FR1
³
9
9
7
0
0
0
Custom Terminal FR1
³
9
9
7
0
0
1
For Serial Program Mode, all commands must be framed by an STX (02 Hex) and ETX (03 Hex). To recall defaults: 1.
Transmit <STX>999999<ETX> through the Serial Port. This will put the scanner in serial program mode. Scanning will be suspended and the scanner will respond with an ACK (06 Hex).
2.
Transmit <STX>999998<ETX> through the Serial Port. This is the Recall Default bar code in the MetroSelect guide. The scanner will respond with an ACK (06 Hex).
3.
Transmit <STX>999999<ETX> through the Serial Port. This will cause the scanner to exit program mode and save the new settings. The scanner will beep 3 times and send an ACK (06 Hex).
If at anytime, the scanner cannot recognize a command, it will respond with a NAK (15 Hex).
Miscellaneous Features
N
3
Page 166
Page 167
SECTION O
DISABLE AUXILIARY PORT * Disable AUX Port
³
4
3
7
3
0
0
AUX PORT AND SECONDARY DEVICE DATA FORMATS FOR THE MS7220, MS7320, AND MS7600 Follow Step 1 to configure the auxiliary port to accept a Metrologic scanner as the secondary scanner. Then follow Step 2 to configure the secondary scanner to match the auxiliary port’s data format. If the secondary scanner is not a Metrologic scanner go to page 3 and follow the instructions under “When using a non-Metrologic RS-232 Device as a secondary”. The auxiliary input port’s data format must match the main output format of the secondary scanner. Step 1: Scan the following bar code to enable the auxiliary port on the MS7220/7320/7600. AUX Port Data Format
³
4
3
7
3
3
0
Continued on next page.
Auxiliary Port Controls
O
1
Page 168
Auxiliary Port Controls
2
O
SECTION O AUX PORT AND SECONDARY DEVICE DATA FORMATS FOR THE MS7220, MS7320, AND MS7600 Step 2: Then scan the following bar codes, in order, to configure the secondary scanner. 1. Enable AUX Output
³
1
2
4
8
1
2. Secondary Scanner Data Format
7
3. Enable Comm Timeouts
³
1
1
8
4
1
2
³
4
3
7
5
3
0
0
5
4. Turn OFF Auxiliary Scanner’s Beeper (Optional)
³
3
1
8
5
Page 169
SECTION O AUX PORT AND SECONDARY DEVICE DATA FORMATS FOR THE MS7220, MS7320, AND MS7600 When using a non-Metrologic RS-232 device as a secondary: Scan the following bar code to enable the auxiliary port on the MS7220/7320/7600. AUX Port General RS-232 Format
³
4
3
7
3
1
0
The auxiliary input port’s data format must match the main output format of the secondary device. The secondary device must be capable of RTS/CTS handshaking and have a carriage return (ASCII 0DH) terminator on the data.
The default settings for the AUX Port General RS-232 Format are: • 38400 baud • 7 data bits • 2 stop bits • Space parity To change these settings refer to Section O, pages 5-8.
Auxiliary Port Controls
O
3
Page 170
Auxiliary Port Controls
SECTION O
O
4
ADDITIONAL AUXILIARY PORT DATA FORMATS
The auxiliary input port’s data format must match the main output format of the secondary device. Enable AUX Port with UPC Supplemental Data Format
Enable AUX Port with Code Select Data Format
³
³
4
3
7
3
4
0
4
3
7
3
5
0
Enable AUX Port with Tech 7, 8 Data Format
Enable AUX Port with Reserved 2 Data Format
³
³
4
3
7
3
6
0
4
3
7
3
8
0
Enable AUX Port with Reserved 3 Data Format
Enable AUX Port with Reserved 1 Data Format
³
³
4
3
7
3
7
0
4
3
7
3
9
0