Page 17
SPECIFICATIONS IS4225 SPECIFICATIONS OPERATIONAL Light Source:
650 nm VLD
Depth of Field:
12.7 mm to 203 mm (.5" to 8") for .33 (13 mil) bar code
Width of Scan Field:
28.6 mm (1.125”) @ face; 102 mm (4”) @ 76.2 mm (3”)
Scan Speed:
52 scans lines per second
Scan Pattern:
Single scan line
Min Bar Width:
0.173 mm (6.8 mil)
Decode Capability:
Autodiscriminates all standard bar codes; for other symbologies call a Metrologic representative
System Interfaces:
RS232, Light Pen Emulation, PC Keyboard Wedge, Stand Alone Keyboard, USB (low speed)
Print Contrast:
35% minimum reflectance difference
Number of Characters Read:
Up to 80 data characters (Maximum number will vary based on symbology and density)
Roll, Pitch, Yaw:
42°, 68°, 52°
Beeper Operation:
3 tones or no beep
Indicators (LED):
red = laser on, ready to scan green = good read, decoding
MECHANICAL Length x Width x Height: Weight: Cable Termination:
70 mm x 49 mm x 24 mm (2.75" x 1.94” x 0.94”) 105 grams (3.7 oz.) Application Dependent
ELECTRICAL Input Voltage:
5VDC ± 0.25V
Power:
0.75 W
Operating Current:
135 mA
DC Transformers:
Class 2; 5VDC @ 300 mA
Laser Class 2:
IEC 60825-1:1993+A1:1997+A2:2001 EN 60825-1:1994+A2:2001+A1:2002
EMC:
FCC, ICES-003 & EN 55022 Class A
ENVIRONMENTAL Operating Temperature:
-20°C to 50°C (-4°F to 122°F)
Storage temperature:
-40°C to 70°C (-40°F to 158°F)
Humidity: Light Levels: Shock: Contaminants: Ventilation:
5% to 95% relative humidity, non-condensing Up to 4842 Lux (450 footcandles) Designed to withstand 1.5 m (5’) drops Sealed to resist airborne particulate contaminants None required Specifications are subject to change without notice.
13
Page 18
DEFAULT SETTINGS Many functions of the scanner can be "configured", that is enabled or disabled. The scanner is shipped from the factory configured to a set of default conditions. All factory default parameters have an asterisk ( * ) in the default column of the charts on the following pages . If an asterisk is not in the default column then the setting is off or disabled by default. Every interface does not support every parameter. If the interface supports a parameter listed in the charts on the following pages, a check mark ( ) will appear. PARAMETER
DEFAULT
Enter Program Mode After Any Scan
*
Enter Program Mode Only on First Scan Short Range Activation Long Range Activation
*
Normal Scan
*
Pulsing Scan Custom Scan Short Same Symbol Rescan Long Same Symbol Rescan
*
Alternate Beeper Tone 1 Alternate Beeper Tone 2
*
Alternate Beeper Tone 3 No Beeper Tone Two Second Timeout No Two Second Timeout
*
Razzberry Tone on Timeout No Tone on Timeout
*
Three Beeps on Timeout Beep Before Transmit
*
Beep After Transmit Baud Rate
9600
Parity
Space
8 Data Bits 7 Data Bits
*
RTS/CTS Character RTS/CTS Message RTS/CTS
14
*
RS232
LIGHT PEN
KEYBOARD WEDGE
USB
Page 19
DEFAULT SETTINGS PARAMETER
DEFAULT
RS232
LIGHT PEN
KEYBOARD WEDGE
USB
ACK/NAK XON/XOFF
*
No Intercharacter Delay 1 Millisecond Intercharacter Delay 5 Millisecond Intercharacter Delay 10 Millisecond Intercharacter Delay 25 Millisecond Intercharacter Delay 100 Millisecond Intercharacter Delay DTR Input DTR Scan Disable “DE” Disable Command LRC Calc+ Transmit RS232 Start LRC on first RS232 Byte Start LRC on Second RS232 Byte
*
Carriage Return
*
Line Feed
*
STX Prefix ETX Suffix Tab Prefix Tab Suffix Prefix ID for UPC/EAN Suffix ID for UPC/EAN Bars High
*
Spaces High Transmit as Scanned
*
Transmit as Code 39 Poll Light Pen 5 Volts No Poll Light Pen
*
Reverse Polarity Idle for Light Pen UPC
*
EAN
*
RSS14 Enable RSS14 ID “]e0” RSS14 App ID “01” RSS14 Check Digit
* * *
RSS Expanded Enable RSS Limited Enable
15
Page 20
DEFAULT SETTINGS PARAMETER
DEFAULT
RSS Limited ID “]e0”
*
RSS Limited App ID “01”
*
RSS Limited Check Digit
*
Full ASCII code 39 Code 39
*
Codabar Code 128
*
Code 93
*
Interleaved 2 of 5 (ITF)
*
Code 11 Hong Kong Matrix 2 of 5 Airline 2 of 5 Minimum 1 Character Code Length Minimum 3 Character Code Length
*
Minimum 6 Character Code Length Set Minimum Character Length Set Character Lock Length Transmit UPC-A Number Sys
*
UPC-A Check Digit Transmit
*
Convert UPC-A to EAN-13 Expand UPC-E UPC-E Check Digit Transmit UPC-E Leading 0 Transmit EAN-8 Check Digit Transmit EAN-13 Check Digit Transmit Convert EAN-8 to EAN-13 “$” Prefix ID for UPC/EAN 2 Digit Supps (Scan) 5 Digit Supps (Scan) Bookland (Scan) Supplement Required Bookland to ISNB Transmit ISNB CD
16
*
RS232
LIGHT PEN
KEYBOARD WEDGE
USB
Page 21
DEFAULT SETTINGS PARAMETER
DEFAULT
RS232
LIGHT PEN
KEYBOARD WEDGE
USB
Mod 43 Check Digit Code 39 Transmit Mod 43 Check Digit Code 39
*
Transmit Start/Stop Code 39 CLSI Editing (Enable) ITF Check Digit Transmit MOD 10 ITF Check Digit I 2 of 5 Symbol Lengths
Variable
ISBN Reformatting Coupon Code 128 ]C1 Transmit Coupon C128 Coupon 128 Group Separator Italian Pharmaceutial Codabar Start and Stop Class ITF Minimum Symbol Length Test Matrix 2 of 5 Check Digit Hong Kong Matrix 2 of 5 MSI - Plessey Test of Check Digit
*
Enable MSI - Plessey Mod 10 Check Digit Enable MSI - Plessey Mod 10/10 Check Digit Transmit MSI - Plessey Check Digit
*
UK Plessey UK Plessey Check Digit UK Plessey Special Format A to X conversion (UK) Scan Count Test Mode Scanability Test Mode Normal Scan/Operating Test Mode Transmit Scanner Parameters Test Mode Code ID Sanyo 635 ECR Protocol Post Software ID Characters “Newcode” Mode A “Newcode” Mode B
17
Page 22
DEFAULT SETTINGS PARAMETER
DEFAULT
BIO DATA Mode Golden Bountiful Formatting Intermec Polling Mode D (limited function) Enable Sineko Mode Enable Caps Lock Mode (for MI951 keyboard wedge) Enable French Wyse 120 PC Term Rochford Tompson Mode RTS Counter Toggle Beep on BEL RS232 Bancorner Mode FedEX parsing Retransmit of Same Code st
1 Programmable Prefix ID nd
2 Programmable Prefix ID st
1 Programmable Suffix ID nd
2 Programmable Suffix ID Clear all Programmable Prefixes and Suffixes SNI Beetle Mode ATKeyboard
*
Type XT Keyboard Type PS2 Keyboard USA Keyboard Belgium Keyboard France Keyboard Germany Keyboard Spain Keyboard Italy Keyboard UK Keyboard IBM KDB4700 Financial Keyboard
18
*
RS232
LIGHT PEN
KEYBOARD WEDGE
USB
Page 23
DEFAULT SETTINGS PARAMETER
DEFAULT
RS232
LIGHT PEN
KEYBOARD WEDGE
USB
Alt Mode Auto Detection or Caps Lock User-Defined Caps Lock F0H Break Code Transmission
*
800 Microsecond Delay-Enter Scan Code
*
15 Millisecond Delay-Enter Scan Code 7-5 Millisecond Delay-Enter Scan Code
TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 20. SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
No LEDs, beep and there is no visible laser
No Power is being supplied to the scanner
Make sure the cable is plugged into the host. Check the host system’s power cable, the outlet and power strip.
No LEDs, beep and there is no visible laser
No power is being supplied from the USB port.
The IS4225 requests 100mA from the USB port. If the USB port cannot supply this, a notification window will appear on the screen.
After scanning a bar code, the Red and Green LEDs are on, but no data is being transmitted to the host.
The scanner is not configured properly for communication with the host.
Re-configure the scanner using the appropriate codes for your scanner model.
USB Keyboard Emulation After scanning a bar code, the scanner beeps, but the characters appear incorrectly in your application. The scanner powers up, but does not scan and/or beep.
The scanner is not configured correctly. An incorrect country has been selected. The scanner is trying to scan a particular bar code symbology that is not enabled.
Re-configure the scanner using the appropriate codes for your scanner model.
Verify that the type of bar code being read is enabled.
19
Page 24
LIMITED WARRANTY The IS4225 ScanGlove® scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The IS4225 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all IS4225 scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and local laws, regulations and ordinances pertaining to their production and labeling. This warranty is limited to repair, replacement of product or refund of product price at the sole discretion of Metrologic. Faulty equipment must be returned to one of the following Metrologic repair facilities: Blackwood, New Jersey, USA; Madrid, Spain; or Suzhou, China. To do this, contact the appropriate Metrologic Customer Service/Repair Department to obtain a Returned Material Authorization (RMA) number. In the event that it is determined the equipment failure is covered under this warranty, Metrologic shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit and return such repaired or replaced Product without charge for service or return freight, whether distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase price. This limited warranty does not extend to any Product, which, in the sole judgment of Metrologic, has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage due to use or misuse produced from integration of the Product into any mechanical, electrical or computer system. The warranty is void if the case of Product is opened by anyone other than Metrologic’s repair department or authorized repair centers. THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES, INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY. IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN.
CORPORATE HEADQUARTERS, NORTH AMERICA
METROLOGIC EUROPEAN REPAIR CENTER (MERC)
Metrologic Instruments, Inc. 90 Coles Rd. Blackwood, NJ 08012-4683 Customer Service Department Tel: 1-800-ID-METRO Fax: 856-228-6673 Email: info@metrologic.com
Metrologic Eria Ibérica, SL C/Alfonso Gomez, 38-40, 1D 28037 Madrid Tel: +34 913 751 249 Fax: +34 913 270 437
MTLG AUTO ID INSTRUMENTS (SHANGHAI) CO., LTD Suzhou Sales Office BLK A, Room# 03/03-04 No.5 Xinghan Street, Xinsu Industrial Square China-Singapore Suahou Industrial Park, Suzhou, PRC Tel: 86-512-67622550 Fax: 86-512-67622560 Email: info@cn.metrologic.com
20