IS4120 ScanQuest Laser Scan Engine Programming Guide, pages 19 to 27

Pages 19 to 27 of 81

The original document is the PDF (241 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic IS4120

Page 19

Enter/Exit Program Mode

4800 Baud Rate

B

R

6

** 9600 Baud Rate

B

R

7

19200 Baud Rate

B

R

8

38400 Baud Rate (Transmit Only)

B

14

R

1

Page 20

Recall Defaults

D

F

1

RS-232 Parameter - Parity Parity is an additional digit that makes the number of bits in the ASCII code odd or even. The scanner’s parity must match the host’s parity. Select this option to make the parity bit always 0.

**Space Parity

P

A

1

Select this option to make the additional parity bit either a 0 or 1 to guarantee an even number of bits.

Even Parity

P

A

3

Select this option to make the parity bit always 1.

Mark Parity

P

A

2

Select this option to make the additional parity bit either a 0 or 1 to guarantee an odd number of bits.

Odd Parity

P

A

4

15

Page 21

Enter/Exit Program Mode

RS-232 Parameter - Data Bits RS-232 serial communication requires ASCII data to transmit in either 7 or 8 data bits. In addition, one parity bit will transmit. If necessary, scan the appropriate bar code that matches your host device’s requirements. 8 Data Bits

D

B

1

** 7 Data Bits

D

B

2

RS-232 Parameter - Hardware Handshaking To prevent scanned information from being lost during transmission, your host device may require an RTS/CTS signal. When RTS/CTS (Ready To Send/Clear To Send) enables, the scanner will output an RTS signal and wait for a CTS signal before any data transmits. The default setting of RTS/CTS disables. If necessary, scan the ENABLE RTS/CTS bar code. Enable RTS/CTS

HH1

** Disable RTS/CTS

HH2

16

Page 22

Recall Defaults

D ** Character RTS/CTS

R

5

5

1

When this option is selected, the scanner will activate and deactivate its RTS signal on each character that it transmits.

6

Message RTS/CTS

R

F

7

When this option is selected, the scanner will activate and deactivate its RTS signal on each message that it transmits. This mode should normally enable for Sanyo registers.

RS-232 Parameter - Software Handshaking For control of the data transmission process, use the following parameters instead of or in addition to the RTS/CTS hardware handshaking option. ACK/NAK

When this option is enabled, the scanner will not scan again unless after transmission of a bar code it receives an ACK (ASCII 06H). The scanner will retransmit the bar code, if it receives an NAK (ASCII 15H).

Enable ACK/NAK

S

H

2

** Disable ACK/NAK

S

XON/XOFF

When this option is enabled, the scanner will stop transmission whenever it receives an XOFF (ASCII 13H). Transmission will resume after it receives an XON (ASCII 11H).

H

1

Enable XON/XOFF

S

H

4

**Disable XON/XOFF

S

H

3 17

Page 23

Enter/Exit Program Mode

RS-232 Parameter - Intercharacter Delay The time specified with an intercharacter delay bar code represents the interim of time between transmission of characters. Some host systems require this delay when receiving transmissions. If necessary, scan the appropriate bar code.

** No Intercharacter Delay

R

2

0

1 Millisecond Intercharacter Delay

R

2

1

5 Millisecond Intercharacter Delay

R

2

2

25 Millisecond Intercharacter Delay

R

18

2

3

Page 24

Recall Defaults

D

F

1

RS-232 Parameter - Scanning Control (DTR Signal) When the DTR (Data Terminal Ready) input is enabled, Enable DTR Input the scanner will not transmit unless an active (+12V) DTR signal is present on the scanner’s DTR input pin. You can disable the scanner by making DTR inactive (-12V) at the H H 3 DTR input pin.

The DTR Scan Disable feature will prevent any scan- ** Disable DTR Input ning when the Enable DTR input feature is chosen. Before enabling the Enable DTR Scan Disable feature, scan the Enable DTR Input bar code. To turn off this feature, H H 4 scan the Recall Defaults bar code. Enable DTR Scan Disable

R

3

2

"DE" Disable Command When this option is enabled, the scanner will stop scanning when it receives an ASCII “D” from the host device. Scanning will resume when the scanner receives an ASCII "E". This feature will only work with RS-232 communication. When this option is chosen, the scanner will not stop scanning when it receives an ASCII "D" from the host device.

Enable "DE" Disable Command

R

9

4

*Disable "DE" Disable Command

R

9

5

19

Page 25

Enter/Exit Program Mode

Longitudinal Redundancy Check (LRC) A Longitudinal Redundancy Check (LRC) is an error checking character that is calculated across a sequence of data characters. It is determined by eXclusive ORing (XOR) the characters to be checked, starting with an initial value of 00H. The result, an "LRC byte" is then transmitted following the data stream and used by the receiving computer to determine if the information was received correctly. In the scanner's case, XOR is performed prior to adding parity bits.

Enable LRC Calc+ Transmit RS-232

R

5

8

**Disable LRC Calc+ Transmit RS-232

R

5

9

Start LRC on First RS-232 Byte

When the LRC is enabled, the scanner defaults to starting the LRC on the second byte of information transmitted. Optionally, the calculation can start on the first byte transmitted.

Record Header/Terminator Select When this option is on, the scanner will transmit a Carriage Return after each bar code.

R

A

0

**Start LRC on Second RS-232 Byte

R

9

9

**CR On

T

R

2

R

1

CR Off

T

20

Page 26

Recall Defaults

D

F

1

When this option is on, the scanner will transmit a Line Feed after each bar code.

** LF On

T

R

4

R

3

LF Off

T

When this option is on, the scanner will transmit a Start of TeXt (ASCII 02H) before each bar code.

STX Prefix On

T

R

6

** STX Prefix Off

T

When this option is on, the scanner will transmit an End of TeXt (ASCII 03H) after each bar code.

R

5

ETX Suffix On

T

R

8

** ETX Suffix Off

T

R

7

21

Page 27

Enter/Exit Program Mode

When this option is on, the scanner will transmit a TAB (ASCII 09H) before each bar code.

Tab Prefix On

T

B

2

** Tab Prefix Off

T

When this option is on, the scanner will transmit a TAB (ASCII 09H) after each bar code.

B

1

Tab Suffix On

T

B

4

** Tab Suffix Off

T

22

B

3