Page 33

Appendix A. Format List Fmt 37xx:

[ABA] [chk dgt] [acct #]

• [ABA], [chk dgt]: - all characters in the field - keep spaces and dashes • [acct #]:

Fmt 38xx:

- work with characters in the acct field only - window of xx characters; xx must be greater than 00 - remove spaces and dashes 'T' [transit] 'A' [acct #] 'C' [check #]

• [transit]:

- all characters in the field - keep dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - include leading characters - keep spaces and dashes

• [check #]:

-all characters in the field

Fmt 39xx:

[transit] <CR> [acct #]

• [transit]:

all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and keep dashes

Fmt 40xx:

[country code] [transit] [acct #]

• [country code]: - '1' for US checks - '2' for Canadian checks • [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

Fmt 4100:

'S' 'T' [transit] 'A' [acct #] 'C' [check #]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- all characters in the field - place a slash ('/') after 10th character - if 10 characters or less, precede with a slash ('/') - remove spaces and dashes - always 6 characters, zero filled remove spaces and dashes

• [check #]:

25

Page 34

MAXI MICR RS232 with 2-Track MSR Fmt 42xx:

US check :

[transit] [acct #]

Can check:

'9' [transit] [acct #]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- always xx characters; zero filled; when xx=00 all characters are sent. - remove spaces and dashes

Fmt 43xx:

[check #] <CR> <CR> [transit] <CR> [acct #]

• [check #]:

- maximum of 6 digits - remove spaces and dashes

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

Fmt 44xx:

[transit] [acct #]

• [transit]:

- all characters in the field - if Canadian check, replace dash with a space

• [acct #]:

- always xx characters, trailing spaces, when xx=00 all characters are sent - remove spaces and dashes

Fmt 45xx:

[transit] <CR> [acct #] <CR> [check #]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces, dashes and leading zeros

• [check #]:

- all characters in the field

Fmt 46xx:

[transit] [acct #] [check #]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- always xx characters, zero filled; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- always 6 characters, zero filled - remove spaces and dashes

26

Page 35

Appendix A. Format List Fmt 47xx:

[transit] 'T' [acct #] 'A' [check #]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- all characters in the field

Fmt 48xx:

[transit] 'T' [acct #] 'A'

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

Fmt 49xx:

[transit] '/' [acct #] '/' [check #] '/' [check type]

• [transit]:

- always 9 characters, zero filled - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- maximum of 9 digits

• [check type]:- personal checks ('1'); commercial checks ('2') Fmt 50xx:

'T' [transit] 'T' 'O' [acct #] 'O' [check #]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- all characters in the field

Fmt 51xx:

'=' [transit] '=' [acct #] '='

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

27

Page 36

MAXI MICR RS232 with 2-Track MSR Fmt 52xx:

'T' [transit] 'T' [acct #] 'A' [check #]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- all characters in the field - remove dashes and spaces

Fmt 53xx:

'/' [transit] '/' [acct #] '/' [check #] '/' [tpc] '/' [status] '/'

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- all characters in the field

• [tpc]:

- all characters in the field

• [status]:

- this is a programmable option that must be enabled (See Table 4-4)

Fmt 54xx:

[transit] [acct #] [check #] [status]

• [transit]:

- always 12 characters, zero filled - remove dashes

• [acct #]:

- always xx characters, zero filled; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- always 12 characters, zero filled - remove dashes and spaces

• [status]:

- this is a programmable option that must be enabled (See Table 4-4)

Fmt 55xx:

'C' '/' [acct #] '/' [transit] '/' [check #] '/' 0000000000

• [acct #]:

- always xx characters, zero filled; when xx=00 all characters are sent - remove spaces and dashes

• [transit]:

- all characters in the field - remove dashes

• [check #]:

- always 6 characters, zero filled - remove dashes and spaces

28

Page 37

Appendix A. Format List Fmt 56xx:

[transit] <CR> [acct #] <CR> [check #] <CR> [amount]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes - all characters in the field - remove dashes and spaces

• [check #]:

• [amount]:

Fmt 57xx:

- all characters in the field - remove dashes and spaces [acct #] <CR> [amount]

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

• [amount]:

- all characters in the field - remove dashes and spaces

Fmt 58xx:

[short transit] [acct #] ':'

• [transit]:

- 3 rightmost characters - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

Fmt 59xx:

[transit] [acct #] <TAB> [check #] [amount]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- always 9 characters, zero filled - remove dashes and spaces

• [amount]:

- all characters in the field - remove dashes and spaces - insert decimal point ('.') before 2nd rightmost digit

29

Page 38

MAXI MICR RS232 with 2-Track MSR Fmt 60xx:

[transit] '/' [acct #] '/' [check #] '/' [check type]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- maximum of 10 characters - remove spaces and dashes - if no check #, remove preceding slash ('/')

• [check type]:- personal checks ('1'); commercial checks ('2') Fmt 61xx:

[transit] <TAB> [acct #] <TAB> [check #] <TAB>

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces, dashes and leading zeros

• [check #]:

- all characters in the field

Fmt 62xx:

'T' [transit] 'T' [acct #] 'A' [check #] 'S' [status]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- all characters in the field - remove dashes and spaces

• [status]:

- this is a programmable option that must be enabled (See Table 4-4).

Fmt 63xx:

[transit] [acct #] [check #]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- always 4 characters, zero filled - remove spaces and dashes

30

Page 39

Appendix A. Format List Fmt 64xx:

[transit] [acct #] [check #] [amount]

• [transit]:

- all characters in the field - keep dashes

• [acct #]:

- always xx characters, trailing spaces; when xx=00 all characters are sent - keep spaces and dashes

• [check #]:

- always 6 characters (N is on quick-init check), trailing spaces - remove spaces and dashes

• [amount]:

- all characters in the field - remove spaces and dashes - insert decimal point ('.') before 2nd rightmost digit

Fmt 65xx:

'!' [transit] '/' [acct #] '/' [check #] '/' [amount]

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- all characters in the field - remove dashes and spaces

• [amount]:

- all characters in the field - remove dashes and spaces

Fmt 66xx:

[transit] [acct #] <CR> '7' '1' <CR>

• [transit]:

- all characters in the field - keep dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

Fmt 67xx:

<CR> <CR> [check #]

• [check #] :

- maximum of xx characters; when x=00 all characters are sent - remove spaces and dashes

31

Page 40

MAXI MICR RS232 with 2-Track MSR Fmt 68xx:

[transit] <TAB> [acct #] <TAB> [check #] <TAB> [amount] <TAB>

• [transit]:

- all characters in the field - remove dashes

• [acct #]:

- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- all characters in the field - remove dashes and spaces

• [amount]:

- all characters in the field - remove dashes, spaces and leading zeros - insert decimal point ('.') before 2nd rightmost digit

Fmt 69xx:

Read OK

: [transit] [acct #] [check #]

Read error: '0' '/' • [transit]:

- all characters in the field - remove dashes

• [acct #]:

- always xx characters, trailing spaces; when xx=00 all characters are sent - remove spaces and dashes

• [check #]:

- always 6 characters, zero filled - remove dashes and spaces

Fmt 70:

[transit] ',' [acct #] ',' [check #] ',' [amount]

• [transit]:

- all characters in the field - keep dashes

• [acct #]:

- always N characters (N is on quick-init check), space filled - remove spaces and dashes from the account

• [check #]:

- always 8 characters, zero filled - remove dashes and spaces

• [amount]:

- all characters in the field - remove dashes and spaces - if amount is not present, remove last ','

Fmt 71:

[acct #] '?' [check #]

• [acct #]:

- work with a window of N characters in the acct field - always N characters (N is on quick-init check), zero filled - remove spaces and dashes

• [check #]:

- maximum of 4 characters - remove spaces and dashes

32