Page 25
APPENDIX A. FORMAT LIST For check reading, the MICR Reader provides the flexibility to format the MICR fields and build a specific output string that will be transmitted to the Host. These output strings are referred to as formats. The Reader has a built-in list of formats (described below) from which the user may select one to become the active format every time a check is read. The formats may be selected using the FC command (Section 4, Commands) or Insta-Change checks provided by MagTek. Each format is assigned a 4-digit number. The first two digits indicate the format number, and the last two digits are specific parameters used for various functions by each format. For example, in format “0415”, the “04” refers to format number 4 and the 15 refers the maximum number of characters allowed for the account field. Note The formats listed in this section apply only to U.S. and Canadian checks. The MICR line on checks from other countries will not be broken or parsed as described in these formats.
A complete description for each format follows. Fmt
00xx:
Raw Data Format - sends the entire MICR line - where: xx - specify what symbol set to use. Choose from the table Add xx + 16 - change multiple spaces to one space Add xx + 32 - Remove all spaces Examples: MICR LINE: T122000218T 1234 5678 9U 1321 FC0001 - t122000218t 1234 5678 9o 1321 (+16) FC0017 - t122000218t 1234 5678 9o 1321 (+32) FC0033 - t122000218t123456789o1321. xx 00 01 02 03 04 05 06 07
Transit T t T T T T t T
On-Us U o O U U U o U
Amount $ a A $ $ $ a $
Dash d D 0 0 0 none
Error ? ? ? * ? * ? ?
17
Page 26
MAXI MICR RS232 with 2-Track MSR Fmt
01xx:
Parsed Text Format FC0100 - Parsed text with dashes FC0101 - Parsed text, replace dashes with “d” Field Labels - TR-transit, AC-account #, CK-check #, AM-amount, TP-tpc, EP-epc Example: - PTTR444455556;AC 999-222-3;CK11045
Fmt
02xx:
Parsed Text Format with Error Labels FC0200 - Parsed text with dashes FC0201 - Parsed text, replace dashes with “d” Error Labels - PE-parsed error, NE-no error, TR-transit error, CK-chk # error, TC-transit check digit error, AM-amount error, OU-on us/account# error, TP-tpc error Examples: - PTTR444455556;AC999-222-3;CK11045/PENE - PTTR111?11111;AC123456/PETR (“?” = unreadable character)
Fmt
03xx:
• [acct #]:
Fmt
04xx:
• [acct #]:
Fmt
05xx:
• [acct #]:
Fmt
06xx:
• [acct #]:
Fmt
07xx:
• [acct #]:
Fmt
08xx:
[acct #] - maximum of xx characters; when xx=00 all characters are sent - keep spaces and dashes [acct #] - maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes [acct #] - maximum of xx characters; when xx=00 all characters are sent - replace spaces and dashes with zeros [acct #] - always xx characters, zero filled; when xx=00 all characters are sent - replace spaces and dashes with zeros [acct #] - always xx characters, zero filled; when xx=00 all characters are sent - remove spaces and dashes [transit] [acct #]
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes
18
Page 27
Appendix A. Format List Fmt
09xx:
[transit] [acct #]
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - replace spaces and dashes with zeros
Fmt 10xx:
[transit] [acct #]
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- always xx characters, zero filled; when xx=00 all characters are sent - replace spaces and dashes with zeros
Fmt 11xx:
[transit] 'T' [acct #] 'A' [check #]
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes
• [check #]:
- all characters in the field
Fmt 12xx:
[transit] 'T' [acct #] 'A' [check #]
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes
• [check #]:
- always 6 characters, zero filled
Fmt 13xx:
[transit] 'T' [acct #] 'A' [check #] '000'
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes
• [check #]:
- always 6 characters, zero filled
19
Page 28
MAXI MICR RS232 with 2-Track MSR Fmt 14xx:
[transit] [acct #] [check #]
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes
• [check #]:
- always 6 characters, zero filled
Fmt 15xx:
[bank #] [acct #]
• [bank #]:
- all characters in the field - keep spaces and dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes
Fmt 16xx:
[bank #] [chk dgt] [acct #]
• [bank #]:
- all characters in the field - keep spaces and dashes
• [chk dgt]:
- all characters (one character long)
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes
Fmt 17xx:
[transit] [acct #]
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - keep spaces and dashes
Fmt 18xx:
[acct #] "/" [check #]
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - keep spaces and dashes
• [check #]:
- all characters in the field
Fmt 19xx:
[transit] [acct #] [check #]
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - replace spaces and dashes with zeros
• [check #]:
- all characters in the field
20
Page 29
Appendix A. Format List Fmt 20xx:
[transit] [acct #] <CR> [check #]
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - replace spaces and dashes with zeros
• [check #]:
- all characters in the field
Fmt 21xx:
[transit] [acct #] [check #]
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- always xx characters, zero filled; when xx=00 all characters are sent - replace spaces and dashes with zeros
• [check #]:
- all characters in the field
Fmt 22xx:
[bank #] [acct #] [check #]
• [bank #]:
- all characters in the field - keep dashes
• [acct #]:
- always xx characters, zero filled; when xx=00 all characters are sent - replace spaces and dashes with zeros
• [check #]:
- all characters in the field
Fmt 23xx:
[error #] [transit] [acct #] [check #] 'S'
• [error #]:
- one digit, always present - '0' read OK - '1' read error: bad char, empty field, invalid length, validation
• [transit]:
- always 9 characters, zero filled - keep dashes
• [acct #]:
- always xx characters, trailing spaces; when xx=00 all characters are sent - remove spaces and dashes
• [check #]:
- always 6 characters, zero filled - remove spaces and dashes
21
Page 30
MAXI MICR RS232 with 2-Track MSR Fmt 24xx:
[transit] 'T' [acct #] 'A' [check #] 'C' [amount] '$'
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes
• [check #]:
- always 6 characters, zero filled
• [amount]:
- all characters in the field
Fmt 25xx:
'M' 'C' [transit] 'D' [acct #] 'E' [check #]
• [transit]:
- all characters in the field - remove dashes and keep spaces (contig spcs = 1 spc) - if the field is empty, remove 'C'
• [acct #]:
- include leading characters - maximum of xx characters; when xx=00 all characters are sent - remove dashes and keep all spaces - if the field is empty, remove 'D'
• [check #]:
- all characters in the field - if the field is empty, remove 'E'
Fmt 26xx: • [acct #]:
Fmt 27xx: • [acct #]:
Fmt 28xx: • [acct #]:
22
[acct #] - work with characters in acct and transit fields - a window of xx characters; xx must be greater than 00 - remove spaces and dashes [acct #] - work with characters in the acct field only - a window of xx characters; xx must be greater than 00 - remove spaces and dashes [acct #] - work with characters in the acct field only - a window of xx characters; xx must be greater than 00 - minimum of 6 digits, fill with zeros if necessary - remove spaces and dashes
Page 31
Appendix A. Format List Fmt 29xx:
'C' '/' [transit] '/' [acct #] '/' [check #] '/' [status]
• [transit]:
- all characters in the field - keep dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes
• [check #]:
- maximum of 6 digits
• [status]:
- this is a programmable option that must be enabled (See Table 4-4).
Fmt 30xx:
[zero fill] [transit] [acct #]
• [zero fill]: - if length of (transit+account) is less than xx; xx must be greater than 00 • [transit]: - all characters in the field - remove dashes • [acct #]:
- all characters in the field - remove spaces and dashes
Fmt 31xx:
[transit] '/' [acct #] '/' [check #]
• [transit]:
- all characters in the field - remove dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes
• [check #]:
- maximum of 10 digits - remove spaces and dashes - if no check number, remove preceding slash ('/')
Fmt 3200:
'^' [transit] '^' [acct #] '^' [check #] '^' [status]
• [transit]:
- all characters in the field - remove dashes
• [acct #]:
- all characters in the field - remove spaces and dashes
• [check #]:
- all characters in the field - remove spaces and dashes
• [status] :
- this is a programmable option that must be enabled (See Table 4-4).
23
Page 32
MAXI MICR RS232 with 2-Track MSR Fmt 3300:
'=' [transit] '=' [acct #] '=' [check #] '=' [status]
• [transit]:
- all characters in the field - remove dashes
• [acct #] :
- maximum of 14 digits - remove spaces and dashes
• [check #]:
- maximum of 8 digits - remove spaces and dashes
• [status]:
- this is a programmable option that must be enabled (See Table 4-4).
Fmt 34xx:
[transit] [acct #] [zero fill]
• [transit]:
- all characters in the field - remove dashes
• [acct #]:
- all characters in the field - remove spaces and dashes
• [zero fill]: - zero filled up to xx; xx must be greater than 00 Fmt 3500:
MA [aux] B [epc] C [tran] D [acct] E [chk] F [tpc] G [amt]
This format is defined specifically for Target Test Checks. A description of the Target Test Check must be loaded in the exception table. • [aux], [epc], [tran], [chk], [tpc], [amt]: - all characters in the field - keep spaces and dashes • [acct]:
Fmt 36xx:
- all characters in the field - keep spaces and remove dashes Read OK : [transit] [acct #] [check #] '/' Read error: '0' '/'
• [transit]:
- all characters in the field - remove spaces and dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent - remove spaces and dashes
• [check #]:
- always 6 characters, zero filled - remove spaces and dashes