Page 21

SECTION 3. OPERATION AND MAINTENANCE This section contains powering, operating, and maintenance procedures. Ensure the Excella is installed and cabling and power are connected as described in Section 2. POWER UP Plug the power supply, P/N 64300098P/N, and cord 71100001, into wall power, and press the start button. The green LED in the middle of the unit should light. OPERATION Check Insertion Enter checks (one check at a time) as indicated in Figure 3-1. The left entry port light will blink when a check is requested.

Figure 3-1. Position for Holding and Entering Check

13

Page 22

Excella STX Installation and Operation

ID Card Insertion Enter ID cards for scanning with the front of the card facing the scan bar, as shown in Figure 3-2. The right exit port will flash when the ID card is requested.

Figure 3-2. Position for Holding and Entering ID Card Magnetic Swipe Reader

Note: The card may be swiped in either direction.

Figure3-3. MSR Card Insertion 14

Page 23

Section 3. Operation and Maintenance

The location LED indicators are shown in Figure 3-4, and the descriptions are in Table 3-1.

Figure 3-4. Location of LED Indicators Table 3-1. Description of LEDs Middle LED (Unit Status)

Description

Steady Green

Power on, everything is OK

Slow Blink Amber

Cover open

Fast Blink Red Middle LED (MSR Status)

Doc jammed. Path not clear

Slow Blink Green

Swipe card in MSR

Steady Read

Card read error

Fast Blink Green Left LED (MICR status)

Card read ok

Blinking Green

Feed check

Steady Red Right LED (ID Card Status)

MICR error

Blinking Green

Feed ID card

15

Page 24

Excella STX Installation and Operation

MAINTENANCE Printer/Cartridge Cleaning The Installation and Removal of the Printer/Cartridges are shown and described in Section 2. Installation. Clean the Printer/Cartridge as follows: The Printer/Cartridges should be taken out when cleaned. See Section 2, Printer/Cartridge Installation and Removal. There are two methods of cleaning the nozzles on the Printer/Cartridges, dry wiping and damp wiping. Use the dry wiping method first, and if more cleaning is required, use the damp wiping method. Figure 3-5 shows the Ink Cartridge.

Figure 3-5. Cleaning the Ink Cartridge Dry Wiping Nozzles Gently wipe the nozzle plate area with a clean, lint-free cloth. Caution Do not wipe ink over the electrical contact area. Damp Wiping Nozzles Perform the following steps: 1. Dampen a clean, lint-free cloth with water. 2. Hold the dampened cloth or tissue in contact with the nozzles for a few seconds. 3. Then gently wipe the nozzle plate. 16

Page 25

Section 3. Operation and Maintenance

Caution Do not wipe the electrical contact area. 4. If ink remains on the nozzle plate, wipe again with a clean dry cloth.

Scan Bar Cleaning With the Outer and Center Covers removed, locate the Hinged Roller Tower and the Scanning Tower. Open the Towers as indicted in Figure 3-6 and Figure 3-7 and perform the following steps: 1. On the Entry side, pull the Tab up and the Hinged Roller Tower down (to the left).

Figure 3-6. Opening Left Scan Bar

17

Page 26

Excella STX Installation and Operation

2. On the Exit side, pull the Tab up and the Scan Bar Tower down (to the right).

Figure 3-7. Opening Right Scan Bar

18

Page 27

Section 3. Operation and Maintenance

3

Clean each Scan Bar with Cleaning Swab, P/N 97200078, as shown in Figure 3-8.

Figure 3-8. Cleaning the Scan Bars Card and Check Path Cleaning Remove the Outside and Center Covers and open the Scan Bars as previously described. Remove larger debris, such as jammed checks or cards from the check and card paths. For finer particles, use compressed air in a can that is commonly used to clean computer keyboards and PC components. Spray the dust and loose particles from the check and card paths. Compressed air in a can may be purchased at any PC retail store.

19

Page 28

Excella STX Installation and Operation

20