Page 27
APPENDIX B. READ IC 21006516 SPEC SHEET 21006516 SMD (SOIC)
Magnetic Stripe F/2F Read/Decode Integrated Circuit
General Information The F/2F Read/Decode Integrated Circuit in intended for use in recovering F/2F encoded data received from a magnetic head. Features • • • • •
150 to more than 12,000 F/2F bits per second.* Low power: Full operation from 2.7 to 5.5 volts. Current below 2.0 mA. Recovers Data with as much as 30% dropout of amplitude.* Accepts amplitudes from below 20% of ISO reference voltage to more than 250% of ISO reference voltage.* Meets or exceeds the requirement for: IEC 1000-4-2 ESD (Electro Static Discharge) IEC 1000-4-3 Radiated EMC Field (2x requirement) IEC 1000-4-4 Electrical Fast Transient Burst requirement (transmissions on I/O cable) * When used with MagTek read heads and recommended circuit. Functional Block Diagram
Functional Description The F/2F Read/Decode I.C. will recover clock and data signals from an F/2F data stream generated from a magnetic head. The I.C. will function for data rates from 150 to more than 12,000 bits per second. Acquisition and tracking of the data within this range is automatic. The F/2F Read/Decode I.C. is composed of three functional sections: • • •
Signal Conditioning and Detection Bit Recovery Enable/Disable Counters
The signal conditioning and detection section amplifies and filters the signal from the magnetic head, rejects common mode noise, and detects the signal peaks. Other features include protection against certain waveform distortions that may be present in the signal. The enable/disable counters provide initialization for the recovery section. These counters initialize both the bit recovery and the signal conditioning and detection sections. The Bit Recovery section locks onto the data rate and performs the recovery of individual bits from the F/2F data stream.
23
Page 28
I/O Interface for TTL Magnetic Stripe Readers Absolute Maximum Ratings (Non-Operating) Supply Voltage .........................7.0 Volts Voltage Input Range.................0 to VCC Output Sink Current..................10 mA Internal Power Dissipation........100 mW Storage Temperature Range....-55 to 150°C Lead Soldering (10 Sec.)..........260°C Electrical Characteristics Unit operates from 2.7 to 5.5 Volts (VCC) and -30° to 70°C Test conditions: VCC = 5.00 Volts, Ambient Temperature = 25°C Table 1: Electrical Characteristics. Parameter Device Current Logic Low Out (VOL) Logic High Out (VOH) Oscillator Frequency
Condition
Min. 1 at +2.0 mA 1 at -2.0 mA 2 ()
Max. 2 0.4
Typ.
VCC - 0.5 1.2
Units mA Volts Volts MHz
Notes: 1. TTL/CMOS compatible. Outputs covered include the following: Card Present, Read Data, Strobe and F/2F. 2. Frequency measured using R2 and C3 component values. Refer to recommended circuit for required values. Signal Timing Diagram
Notes: 1. Card Present, Data, and Strobe are negative true logic. 2. Card Present goes low after 14-15 head flux reversals. 3. Card Present returns to high level approximently 150mS after the last flux transition. 4. Data is valid 1.0^S (min.) before the leading negative edge of strobe and remains valid until approximently 1.0^S before the next STROBE. DATA The DATA signal is valid while the STROBE is low. If the DATA signal is high, the bit is a zero. If the DATA signal is low, the bit is a one. STROBE The STROBE signal indicates when DATA is valid. It is recommended that DATA be loaded by the user with the leading negative edge of the STROBE. CARD PRESENT CARD PRESENT will go low after 14-15 flux reversals from the head. It will return high if Reset or about 150 milliseconds after the last flux reversal. The CARD PRESENT signal can be tied together with other card present signals from more than one IC, however use only one pull-up resistor (R4). E.g., if this is a 3 track reader, all 3 CARD PRESENTS would be tied together using a single 10K resistor.
24
Page 29
Read IC 21006516 Spec Sheet When no card is being moved through the unit, the DATA, STROBE and CARD PRESENT signals are high. The signal timing diagram shown above represents the data along with other signals that are generated during the reading process. Reset Feature In normal operation, the I.C. resets itself approximately 150 milliseconds after the last flux reversal from the magnetic head. Reset may be forced by applying a pulse of 1.0 to 100 microseconds to the RESET pin. The positive edge of the pulse will reset the I.C. Connection Diagram (Pin Outs)
Recommended Circuit This circuit is intended for use in systems employing F/2F data such as ID cards that conform to ISO 7811-2 or 7811-6.
21006516
VCC May be +2.7V to +5.5V
Tolerances: Resistors ±5%; C1, C3 ±5% NPO; other capacitors non-critical. * R3 has different values for Rev B and Rev G. The table bellow shows the value of R3. Table 2: Value of R3. Rev B R3
470K
Rev G 1.5M
Rev H 1.5M
Printed Circuit Board Layout Requirements The I.C. is a combined digital and analog system. The analog signal pins are very low level. Good layout practice requires that there be a separation of head and other analog signals from the digital outputs. The digital signals are: DATA, STROBE, CARD PRESENT, F/2F OUT, OSC-OUT and OSC-IN. The analog signals in order of sensitivity are HEAD in 1&2, SUM, DRIVE, GSR and BIAS. The digital signals must not pass near the first four analog signals. The layout below illustrates the requirements.
25
Page 30
I/O Interface for TTL Magnetic Stripe Readers
Caution Keep Data, Strobe, and Card Present signals away from Head 1 and Head 2 signals.
SOIC Physical Dimensions
REGISTERED TO ISO 9001:2000 20725 South Annalee, Carson, CA. 90746 Phone: (310) 631-8602, Help Line (651) 415-6800 Fax (310) 631-3956 http://www.magtek.com © P/N 99821066-11, 6-24-03, Copyright 1998 -2003, MagTek, Inc.
26