Page 45

Operation Powering On/Off Connect the VX1 to a power source, either AC or Vehicle. The power (on/off) switch is a toggle switch located on the bottom of the VX1. The switch is sealed by a rubber boot seal. The Status LED or the display, located on the front of the VX1, is lit when the power is on. Note:

Always turn the computer off prior to connecting or disconnecting any power source.

Figure 36 The VX1 Power Switch Powering off the VX1 before a write (to disk) function has completed, may result in the corruption of the flash drive. When the system is turned off, the current contents of RAM are lost. Save any needed data and exit in an orderly fashion from any running programs before turning the system off. You are now ready to use the computer. Enter data using the keyboard or a Serial Barcode Scanner.

E-EQ-VX1OGWW-K-ARC

VX1 User’s Guide

Page 46

40

Powering On/Off

Reset Key Sequence (Reboot) To reboot the VX1 without turning the computer off, press <CTRL> + <ALT> + <DEL> or <CTRL> + <ALT> + <numeric .>

ATTENTION:

Rebooting the VX1, before a write (to disk) function has completed, may result in the corruption of data on the hard drive.

When the system is rebooted, the current contents of RAM are lost. Save any needed data and exit in an orderly fashion from any running programs before rebooting. When the VX1 is turned on or rebooted, the following settings are restored from flash memory and are configured using CMOS Setup.

Factory Default Settings Boot Sequence Show Setup Prompt Display POST Msgs Show Summary Screen Power Management CPU Timer Keyboard Backlight Keyboard Backlight Timer Display Timer Suspend Timer Off Timer Caps Lock at boot NumLock at boot Repeat Delay Repeat Rate CTRL+ALT+DEL DOS Font COM1 Pin 9 COM2 Pin 9 EL Op Mode

A: then C: Disabled Disabled Disabled Enabled Aggressive (1 sec) Timed 1 min. 1 min. 0 min. 1 min. Off On 0.5 seconds 10 chars/sec Reboot 8x16 5V RI 4-Bit

Power On Default Settings Keyboard Backlight Beeper EL Brightness

VX1 User’s Guide uses CMOS setting Restored to prior setting 100%

E-EQ-VX1OGWW-K-ARC

Page 47

Cleaning the Glass Display/Scanner Aperture

41

Cleaning the Glass Display/Scanner Aperture Keep fingers and rough or sharp objects away from the scan aperture and display. If the glass becomes soiled or smudged, clean only with a standard household cleaner such as Windex® without vinegar or use Isopropyl Alcohol. Do not use paper towels or harsh-chemical-based cleaning fluids since they may result in damage to the glass surface. Use a clean, damp, lint-free cloth. Do not scrub optical surfaces. If possible, clean only those areas which are soiled. Lint/particulates can be removed with clean, filtered canned air.

Adjust Screen Display Note:

The <F6> and <F7> keys (Contrast Up and Contrast Down) have no function as the VX1 has an electroluminescent screen. Contact your LXE representative for future enhancements using these keys.

Set Display Brightness First, press the 2nd key to place the VX1 in Secondary Mode. The VX1 brightness keys control the electroluminescent display in the following way: Icon

E-EQ-VX1OGWW-K-ARC

Key

Description

<F4>

Pressing and holding this key increases the brightness of the display

<F5>

Pressing and holding this key decreases the brightness of the display

VX1 User’s Guide

Page 48

42

Keyboard Backlight Control Key

Keyboard Backlight Control Key The electroluminescent display remains on when the Backlight Control key turns the keyboard backlight off. (Power Management may be configured so they both time out simultaneously.) First, press the 2nd key to place the VX1 in Secondary Mode. Then press the <F10> or Backlight Control key. When the keyboard backlight is on, pressing the Backlight Control key sequence (2nd and <F10>) turns the keyboard backlight off.

Set Speaker Volume First, press the 2nd key to place the VX1 in Secondary Mode. The VX1 volume keys control the speaker volume in the following way: Icon

VX1 User’s Guide

Key

Description

<F8>

Pressing and holding this key increases the speaker volume of the VX1.

<F9>

Pressing and holding this key decreases the speaker volume of the VX1.

E-EQ-VX1OGWW-K-ARC

Page 49

Panning the Display

43

Panning the Display The VX1 display can be panned up and down in order to view the entire virtual screen. Display panning can also be controlled by an application running on the VX1. When at the DOS prompt: Display Up

Press 2nd key then <Ctrl> then <UpArrow> to move the screen display up.

Display Down

Press 2nd key then <Ctrl> then <DownArrow> to move the screen display down.

When running an LXE Terminal Emulation (TE) program, refer to the Window Manager section of the TE Reference Guide for instruction on panning the display. The default screen display begins at line 1 and displays 12 lines: . . . . . . . . . 10 . . . . . . . . . 20 . . . . 25

. . . . . . . . . 10 . . . . . . . . . 20 . . . . . . . . . 30 . . . . . . . . . 40 . . . . . . . . . 50 . . . . . . . . . 60 . . . . . . . . . 70 . . . . . . . . . 80 INVENTORY/ORDER STATUS PART NUMBER: 147265-0026 QUANTITY: 416 UNALLOCATED: 48

CUST. ORDER # 152876 153390 158723 159316 159736 160345

09/15

CODE:

QUANTITY 23 45 122 76 55 47

SHIP DATE 09/17 09/23 10/07 10/08 10/22 10/25

13

STD. REORDER LEVEL: 150 STD. ORDER QUANTITY: 500

PROJECTED INVENTORY 393 348 226 150 95 48

PAGE 1/1

Figure 37 Panning, Upper Display Window

E-EQ-VX1OGWW-K-ARC

VX1 User’s Guide

Page 50

44

Panning the Display The first pan down command moves the pointer to line 11 and displays 12 lines (lines 11 through 22): . . . . . . . . . 10 . . . . . . . . . 20 . . . . 25

. . . . . . . . . 10 . . . . . . . . . 20 . . . . . . . . . 30 . . . . . . . . . 40 . . . . . . . . . 50 . . . . . . . . . 60 . . . . . . . . . 70 . . . . . . . . . 80 INVENTORY/ORDER STATUS PART NUMBER: 147265-0026 QUANTITY: 416 UNALLOCATED: 48

CUST. ORDER # 152876 153390 158723 159316 159736 160345

CODE:

QUANTITY 23 45 122 76 55 47

13

SHIP DATE 09/17 09/23 10/07 10/08 10/22 10/25

STD. REORDER LEVEL: 150 STD. ORDER QUANTITY: 500

PROJECTED INVENTORY 393 348 226 150 95 48

09/15

PAGE 1/1

Figure 38 Panning, Center Display Window The second pan down command moves the pointer to line 14 and displays 12 lines (lines 14 through 25): . . . . . . . . . 10 . . . . . . . . . 20 . . . . 25

. . . . . . . . . 10 . . . . . . . . . 20 . . . . . . . . . 30 . . . . . . . . . 40 . . . . . . . . . 50 . . . . . . . . . 60 . . . . . . . . . 70 . . . . . . . . . 80 INVENTORY/ORDER STATUS PART NUMBER: 147265-0026 QUANTITY: 416 UNALLOCATED: 48

CUST. ORDER # 152876 153390 158723 159316 159736 160345

09/15

CODE:

QUANTITY 23 45 122 76 55 47

SHIP DATE 09/17 09/23 10/07 10/08 10/22 10/25

13

STD. REORDER LEVEL: 150 STD. ORDER QUANTITY: 500

PROJECTED INVENTORY 393 348 226 150 95 48

PAGE 1/1

Figure 39 Panning, Lower Display Window At this point, a pan up command moves the pointer to line 4. The next pan up command moves the pointer to line 1. A pan up command at line 1 does not wrap the display.

VX1 User’s Guide

E-EQ-VX1OGWW-K-ARC

Page 51

Power Status and the Status LED

45

Power Status and the Status LED The VX1 has a Status LED, located on the front of the unit, that is illuminated green when the unit is powered on. The Status LED and the display are dark when power is disconnected. Note:

This LED should not be lit when power is disconnected from the VX1.

Figure 40 Status LED Indicator The LED changes color and state depending on power status. Status LED

Condition

Off

VX1 is Off. - or The VX1 is powered On and the display is On.

Steady Green

The VX1 is powered On and the display is Off. Press any key to turn the display On. - or The VX1 is in the Suspend state. The VX1 is placed in Suspend state by pressing the 2nd key then <F>. This key sequence can be used at any time. Press the Resume key sequence (2nd + <F3>) to exit the Suspend state. When the VX1 enters the Suspend state, the display and keyboard backlights are turned off. The beeper is active.

Blinking Green

Main Power Failure. The VX1 is in Critical Suspend mode. The VX1 is drawing power from the backup battery. Restore main power. The VX1 will turn off after entering Critical Suspend.

Normal Mode When the display and backlight are on, PCMCIA sockets are powered, video timer is active, COM1 and COM2 have power, speaker is enabled and, upon initial startup, the keyboard buffer is empty. The Status LED is off.

E-EQ-VX1OGWW-K-ARC

VX1 User’s Guide

Page 52

46

Power Status and the Status LED

Video Timeout State The Video Timer value is set using CMOS Setup (see the “VX1 Reference Guide”). When the video timer times out and there has been no keyboard input, access to video memory or COM port activity, the screen display is turned off. The Status LED on the keyboard is illuminated and steady during Video timeout state. Any keyboard input or COM port activity will bring the VX1 out of Video Timeout and the video timer begins the countdown again. Pressing the 2nd key has no effect when the VX1 is in Video Timeout. Either a Shift, Ctrl or an Alt keypress will wake the VX1. The keypress buffer (including sticky key settings) is cleared when the VX1 returns from Video Timeout state. Host messages that update the display wake the system from the Video Timeout state.

Suspend Mode The VX1 is placed in Suspend Mode by pressing the 2nd key then <F3>. This key sequence can be used at any time. The VX1 is brought out of Suspend Mode by pressing the 2nd key then <F3>. The Status LED illuminates green when the VX1 is in Suspend Mode. Note:

If the Power button is pressed when the VX1 is in Suspend Mode, the unit is placed in suspend state (for a minimum of four seconds) for the amount of time specified in the Off Timer, plus the time specified in the Suspend parameters, prior to the unit powering completely off.

The LED remains illuminated until: •

Resume key sequence (2nd then <F3>) is pressed or

•

Vehicle power is removed from the VX1 or

•

The VX1 power switch is turned off.

When the VX1 enters Suspend Mode, the display and keyboard backlights are turned off and the Status LED illuminates green. The beeper is active. When the VX1 is in Suspend Mode and the Resume/Suspend key sequence is pressed: •

The display and keyboard backlight are turned on.

•

The Status LED turns off.

•

Sticky key settings and keypresses are cleared and ignored during Suspend.

Powering the VX1 off when it is in the suspend state causes all unsaved work to be discarded e.g. TE forms, barcode reads, etc.

VX1 User’s Guide

E-EQ-VX1OGWW-K-ARC

Page 53

Power Status and the Status LED

47

Critical Suspend State The Critical Suspend state occurs when the power switch is turned off (or power is disconnected) and the backup battery is supplying power to the VX1. Backup Battery Power Failure can occur because the backup battery's energy has been depleted or the backup battery has been removed. When the unit is in the Critical Suspend state the Status LED blinks green, all peripherals are shut down, the CPU clock is stopped, power is removed from the PCMCIA card(s) and the VX1 may beep. The VX1 is saving the state prior to shut down and cannot be used. If the power supply is re-connected before the Off Timer expires the unit transitions to the On state. When the Off Timer expires the unit turns itself off and all unsaved information is lost. Connect the main power source and toggle the On/Off switch to On to turn the unit back on. Note:

The Off Timer is configured in the BIOS Setup (see the “VX1 Reference Guide.”)

E-EQ-VX1OGWW-K-ARC

VX1 User’s Guide

Page 54

48

Laser Barcode Scanner Warnings

Laser Barcode Scanner Warnings •

Do not look into the laser’s lens.

•

Do not stare directly into the laser beam.

•

Do not remove the laser caution labels from the scanner.

•

Do not connect the tethered laser barcode scanner to any other device.

Caution:

Please read the caution labels. Avoid exposure. Laser light is emitted from the scanner’s aperture. Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. The scanner uses laser light. The following labels are representations of caution and warning labels placed on laser scanners.

Figure 41 Caution Labels Class II Scanner

Figure 42 Caution Labels Class IIIA Scanner

Do not pour, spray, or spill any liquid on the scanner. The Barcode Scanner contains the circuitry, scanning motor and laser. Handle with appropriate care.

VX1 User’s Guide

E-EQ-VX1OGWW-K-ARC

Page 55

Enter Data

49

Enter Data You can enter data into the VX1 through several different methods. A tethered barcode scanner connected to a serial port provides barcode data entry, the serial ports are used to input/output data, and the keyboard provides manual entry.

Keyboard Entry Refer to “Appendix A - Key Maps” for terminal emulation specific keypresses. The keyboard is used to manually input data that is not collected otherwise. Almost any function that a full sized computer keyboard can provide is duplicated on the VX1 keyboard but it may take a few more keystrokes to accomplish a keyed task. Almost every key has two or three different functions. The primary alpha or numeric character is printed on the key. For example, when the 2nd key is first pressed, press the desired second-function key to produce the 2nd character i.e. <2nd+F1> toggles the CAPS lock function. The specific 2nd character is printed on the corresponding key. Please refer to “Appendix A - Key Maps” for instruction on the specific keypresses to access all keyboard functions.

Scanner Entry The following section is directed toward a tethered scanner connected to a serial port on the VX1.

Aiming the Barcode Scanner Aim the scanner away from you, direct it at the barcode and press the trigger to scan. The Scan On LED (or equivalent) turns red to indicate the scanner is on. Adjust the aim so that the thin, red laser beam covers the entire length of the barcode. Some scanners use a laser aiming beam which then spreads into a wide beam when the scanner's Aiming Beam Timer expires. Place the aiming beam in the center of the barcode and hold the scanner steady until the beam spreads and the barcode is decoded. Beeps may be heard as the barcode is decoded. Refer to the barcode scanner user's guide for information on the Aiming Beam Timer and beep sequences, and the TE reference guide for host generated beep sequences. The scan beam must cross every bar and space on the barcode.

Correct Scan

E-EQ-VX1OGWW-K-ARC

Incorrect Scan Figure 43 Scan Beam

Incorrect Scan

VX1 User’s Guide

Page 56

50

Enter Data

Distance from Label Large barcodes can be scanned at the maximum distance. Hold the scanner closer to small barcodes (or with bars that are very close together). Note:

Do not position the scanner exactly perpendicular to the barcode being scanned. In this position, light can bounce back into the scanner’s exit window, and possibly prevent a successful decode.

Successful Scan When the scan is successful, the scanner's good scan indicator illuminates, the scan on indicator is off, and the currently running application may produce a distinctive audible tone.

Unsuccessful Scan When the scan is unsuccessful, the scan on indicator remains illuminated and the currently running application may produce distinctive audible tones. Check the following: •

Is the scanner programmed for the barcode being read?

•

Check the barcode for marks or physical damage e.g. ripped label, missing section, etc.

•

Try scanning test symbols of the same code type at different distances and angles.

Cleaning the Scanner Aperture Keep fingers and rough or sharp objects away from the scan aperture. Wipe the scanner window periodically with a damp, soft cloth. Remove lint or foreign material with clean, filtered canned air. Do not scrub optical surfaces, clean only those areas which are soiled.

VX1 User’s Guide

E-EQ-VX1OGWW-K-ARC