The text of a manual · part 3 of 9
VX1 User's Guide: The VX1 Vehicle Mount Computer, pages 16 to 24
Pages 16 to 24 of 80, from VX1 User's Guide
The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the LXE VX1
Page 16
10
The Keyboards
Secondary Keys LED The VX1 keyboard is equipped with several secondary keys. These keys are identified by the superscripted text found on the keyboard keys. The secondary keys are accessible by using two (2) keystrokes: the 2nd key followed by the superscripted key.
Figure 8 The Secondary Key Once the 2nd state is enabled (by pressing the 2nd key) the Secondary Mode LED is illuminated and the 2nd state is enabled until another key is pressed. The 2nd key is toggled on with a 2nd keypress and then immediately off with another 2nd keypress. For example: Press 2nd and <F10> to toggle the keyboard backlight on and off. Press 2nd and <F1> to turn Caps-Lock on and off. Press 2nd and <F2> to initiate the DOS Break command. Press 2nd and <F3> to toggle the Resume/Suspend Mode on and off.
VX1 User’s Guide
E-EQ-VX1OGWW-K-ARC
Page 17
The Keyboards
11
Status LED
Figure 9 The Status LED The Status LED, located on the front of the unit, is illuminated green when the unit is powered on and the display is off. The Status LED is dark when power is disconnected (or the power is on and the display is on). Note:
This LED should not be lit when power is disconnected from the VX1.
Entering and exiting the Suspend Mode is performed by pressing the Resume/Suspend key sequence -- 2nd key then <F3>. The status LED is green when the VX1 is in Suspend Mode. Suspend Mode is the lowest powerconsumption state possible, while still retaining the system’s status. When the VX1 enters Suspend Mode, the display and keyboard backlight are turned off and the status LED stays green. The beeper is active. When the VX1 is in Suspend Mode and the Resume/Suspend key is pressed, the display and keyboard backlight are turned on and the status LED turns off.
E-EQ-VX1OGWW-K-ARC
VX1 User’s Guide
Page 18
12
The Keyboards
Control Keys The VX1 has several control keys. One key controls the keyboard backlight, a pair of keys controls the volume and another pair of keys controls the display brightness. The VX1 must be placed in Secondary Mode to access these functions. Note:
The <F6> and <F7> keys (Contrast Up and Contrast Down) have no function as the VX1 has an electroluminescent screen. Contact your LXE representative for future enhancements using these keys.
1
Display Brightness Control Keys
2
Display Contrast Control Keys (Not Used)
3
Speaker Volume Control keys
4
Backlight Control Key
Figure 10 The VX1 Display Controls
VX1 User’s Guide
E-EQ-VX1OGWW-K-ARC
Page 19
PCMCIA Slots
13
PCMCIA Slots The VX1 has one active PCMCIA slot – the right slot, slot 0. It supports the Personal Computer Memory Card International Association (PCMCIA) 2.1 standards. Slot 0 (the right slot, usually configured as Drive D:) accepts Type I, II or III PCMCIA SRAM cards. LXE supports only Type II 2.4GHz Spread Spectrum and Type III 900MHz Spread Spectrum radios. Slot 1 (the left slot) is not used.
1
Slot 1 (Left) Unused
2
Slot 0 (Right)
Figure 11 The VX1 PCMCIA Slots
Radio Cards Common use of the PC slot is to insert a radio PCMCIA card or a memory/ SRAM card. Not all units require radio cards or memory cards. Possible radio configurations are: LXE TE Software
2.4GHz
900MHz
ANSI Plus x x
LDS Plus x x
IBM 3270/IBM 5250 IBM TN3270/TN5250
Note:
x x
The 900MHz radio is obsolete. Companion terminal emulation software is obsolete (3250 DOS TE, 5250 DOS TE, ANSI for 900MHz and LDS for 900MHz systems).
E-EQ-VX1OGWW-K-ARC
VX1 User’s Guide
Page 20
14
Power Supply
Power Supply Vehicle power input for the VX1 is 12V to 80V DC and is accepted without the need to perform any manual adjustments within the VX1. See the section titled “Installation”, sub-section titled “Vehicle 12-80VDC Direct Connection.” If 12V to 80V DC power is not available – for example, in an office environment – an optional external Universal Input Power Supply can be used to convert AC wall power to an appropriate DC level. See the section titled “Installation”, sub-section titled “External Power Supply.” Power input is fused for protection and the fuse is externally accessible. See section titled “Installation”, sub-section titled “Fuse Replacement for the VX1.”
Backup Battery The internal 50mAh Nickel Cadmium (NiCd) backup battery provides power to the unit for a short amount of time when the primary power supply has been depleted, removed or has failed. The backup battery requires no user intervention other than periodic conditioning (see Appendix D "Utilities" in the VX1 Reference Guide). Replacement is performed by LXE. Note:
VX1 User’s Guide
When there is no external power supplied to the VX1, the unit is powered by the backup battery. When the backup battery is depleted, the BIOS parameters are reset to their factory default settings.
E-EQ-VX1OGWW-K-ARC
Page 21
Getting Help
15
Getting Help LXE user guides are now available on CD and they can also be viewed/downloaded from the LXE ServicePass website. Contact your LXE representative to obtain the LXE Manuals CD or access to the LXE ServicePass website. You can also check the LXE ServicePass website for the latest manual releases. Note:
Obsolete/archived manuals are not available on the LXE Manuals CD. They are available for download from the ServicePass website only. You can get help from LXE by calling the telephone numbers listed on the LXE Manuals CD, in the file titled “Contacting LXE”. This information is also available on the LXE website. Explanations of terms and acronyms used in this manual are located in the file titled "LXE Technical Glossary" on the LXE Manuals CD and on the LXE website.
Manuals and Accessories Manuals The following manuals used for the VX1 are available from LXE: User Guides (for the daily user) • VX1 User's Guide – English (Obsolete) • VX1 User's Guide – German (Obsolete) Reference Guides (for the SysAdmin) • ANSI Plus Reference Guide • DOS API Programming Guide • DOS Autoconfigurator Installation Instruction (Obsolete) • LDS Plus Reference Guide • VX1 Reference Guide (ROM-DOS) (Obsolete) • SNMP Agent Reference Guide • TN3270 Terminal Reference Guide • TN5250 Terminal Reference Guide Networking • Telnet Manager Reference Guide • WaveLink Avalanche for DOS Reference Guide Peripherals • Getting the Most from Your Batteries • LXE Technical Glossary • PCMCIA Card Management and LXE DOS Computers Archived/Obsolete (Available on the LXE ServicePass website) • ANSI Plus Reference Guide (900MHz) Rev H • LDS Plus Reference Guide (900MHz) Rev E • 3270 DOS TE Reference Guide • 3270 Programmer’s Reference Guide • 5250 DOS TE Reference Guide • 5250 Programmer’s Reference Guide • 6200 Network Management Guide
E-EQ-VX1OGWW-K-ARC
VX1 User’s Guide
Page 22
16
Manuals and Accessories
Accessories 10-80VDC 12ft Input Power Cable
1380A053CBL12ML3
120 – 240 VAC Power Supply
9000A304PSACWW
1280/90 to VXX Adapter kit (See note A)
9000A016BRKTADPTKIT
2.4GHz Replacement Antenna
153180-0001
900 MHz Replacement Antenna, 3”
148693-0001
900 MHz Replacement Antenna, 8”
148694-0001
900MHz Right Angle Antenna
7160L21
Mounting bracket for VX1/VX2
VXXA003BRACKET
Power Filter only, filters power spikes (See note B)
9000A308PSFILTERWW
Printer Cable, 8ft, VX1/VX2 to Zebra QL420 printer
9000A062CBLD9COMTEC
Remote Antenna Assembly Kit, 6ft
9000A278ANTREMOTE6
Remote Antenna Assembly Kit, 8 ft. (900MHz or 2.4GHz)
9000A279ANTREMOTE8
Replacement rubber isolator (each)
158293-0001
Rt. Angle Remote Antenna Assembly Kit, 15ft
9000A281ANTREMOT15RT
Rt. Angle Remote Antenna Assembly Kit, 6ft
9000A280ANTREMOTE6RT
Scanner, LS3408ER, 9’ Cbl, WW
8520A326SCNRERDA9F
Scanner, LS3408FZ, 9’ Cbl, WW
8510A326SCNRFZYDA9F
Scanner, Powerscan LR 12’ Cbl, US
8310A327SCNRPWRLR12DA9F
Scanner, Powerscan SR, 11’ Cbl, PS/2, US
8300A330SCNRPWRSR11PS2
Scanner, Powerscan XLR, 12’ Cbl, PS/2, US
8320A330SCNRPWRXLR11PS2
Scanner, Powerscan XLR, 12’ Cbl, US
8320A327SCNRPWRXLR12DA9F
Scanner, Powerscan, LR, 12’ Cbl, PS/2, US
8310A330SCNRPWRLR11PS2
Scanner, Powerscan, LR, 8’ Cbl, WW
8310A326SCNRPWRLR8DA9F
Scanner, Powerscan, SR, 12’ Cbl, US
8300A327SCNRPWRSR12DA9F
Scanner, Powerscan, SR, 8’ Cbl, WW
8300A326SCNRPWRSR8DA9F
Scanner, Powerscan, XLR, 8’ Cbl, WW
8320A326SCNRPWRXLR8DA9F
When using the 8500 series tethered scanners (LS3408), the tethered scanner Power Mode must be set to “Reduced Power Mode”. The default is “Continuous On”. Setting the scanner to reduced power mode will not impact performance of the 8500 series tethered scanners. Refer to the manufacturers user guide for instruction. Note A: Adapter Kit Includes Hardware and Adapter Power Cord to mount a VX1/2 Computer utilizing the existing 1280 mounting bracket. Integrated keyboard bracket can not be used in conjunction with the adapter bracket. Note B: This power filter may be required when customers have unclean forklift power in which power spikes cause problems with the vehicle computer.
VX1 User’s Guide
E-EQ-VX1OGWW-K-ARC
Page 23
Manuals and Accessories
17
Revision History Revision J – October 2005 Entire Manual : Updated document presentation to reflect LXE’s 2005 documentation standards. Added 2005 LXE logo. Added WEEE statement to “Notices” and Appendix B. Marked obsolete tethered scanners in “Accessories”. Noted obsolescence of 900MHz radios (and companion TE software) and the Symbol 2Meg radio. Added up-to-date “Getting Help” including Manuals and Accessories. Revision H – August 2004 Introduction : Added 8500 Series Tethered Scanners to Accessories. Added Power Settings recommendation for 8500 Scanners. Updated Accessories listing effective July 2004. Appendix B – Regulatory Notices and Safety Information : Updated the 6726 Declaration of Conformity. Revision G – May 2004 Entire Manual : Renamed to “VX1 User’s Guide” from “VX1 Installation and Operator’s Guide” . Installation : Added section titled “Vehicle Remote Antenna Mount”. From the Vehicle Power Supply Installation procedure, removed “The green wire is not used. Do not connect this wire. If the green wire has a bare end, use electrical tape (or otherwise insulated) to cover the bare end and ensure the bare wire does not contact anything.” The VX1 must be grounded when installed in a vehicle. Revision F – July 2003 Appendix B – Regulatory Notices and Safety Information : Revised “Approvals” table. Added 6816 Declaration of Compliance. Revision E – September 2002 Installation : Added 12-60VDC Direct Connection Instruction. Added information for negative and floating ground vehicles. Added non-conducting strap information. Added Ground Wire Not Used note. Operation : Added new phrasing for “Cleaning the Display/Scanner Aperture”. Revision D – June 2002 Appendix B – Regulatory Notices and Safety Information : Revise “Approvals” table. Revise “A/C Power Supply Safety Statement”. Revision A – April 2001, Initial Release
E-EQ-VX1OGWW-K-ARC
VX1 User’s Guide
Page 24
18 Manuals and Accessories [ nal
VX1 User’s Guide E-EQ-VX1OGWW-K-ARC