Page 14

8

Introduction

Chapter 2 Installation and Operation Introduction The life and capacity of a Lithium Ion battery pack can vary significantly depending on the discharge current and the environment in which it is used. As with all batteries, expect to see a reduction in the total number of operations a fully charged battery pack can deliver as it ages. Charging times may increase but will not exceed four hours. Battery packs do not need to be fully discharged between charge cycles. The analyze feature allows you to determine the current condition of the battery pack. The capacity of the battery (in mAH) can be compared to the battery specification. Expect a battery pack with less than 80% of its rated capacity to provide noticeably shorter operating time for your mobile device.

LXE Battery Pack Part Number

156213-0001 2381A376BATT1600

158224-0001 MX3A378BATT and 159922-0001 MX3A380RFIDBATT

Construction

Lithium Ion

Lithium Ion

Specified Capacity

1400mAh

1800mAh

80% of Specified Capacity

1120mAh

1440mAh

Normal Operations The optimal operating temperature range for the Multi-Charger Plus is between 50°F and 95°F (10°C and 35°C). While charging, the charger/analyzer and battery pack will generate enough heat to feel warm. This is normal and does not indicate a problem. Do not store the battery pack in direct sunlight or anywhere the battery pack cannot cool down. If the battery pack is hot after removal from the computer, allow it to cool at room temperature before placing it in the charger. Charge times may increase significantly if the battery is warm or hot, since it takes the battery pack longer to cool down while in the charger pocket. If the battery pack is hot from severe environmental use and immediate recharging is necessary, place the battery pack in a cool air stream or in a cool location until it is no longer warm to the touch before charging.

Maintenance Use a clean soft cloth to wipe any dirt, moisture or grease from the battery pack, contacts or the charger. Do not use any liquid to clean the battery pack or charger contacts.

MX3 Multi-Charger Plus User’s Guide

E-EQ-MX3MCPLUS-F-ARC

Page 15

9

Introduction

Storage Battery packs should be kept in a cool, dry place whenever possible. Do not store battery packs in direct sunlight, on a metal surface, or anywhere the battery pack cannot cool down. Do not leave the battery pack in a non-operating charger. The battery pack may discharge through the charger rather than hold its charge.

Service There are no user serviceable parts in the LXE 156213-0001, 158224-0001 or 159922-0001 Rechargeable Lithium Ion Battery Pack or the Multi-Charger Plus. Should your charger require service, contact LXE. Please refer to “Getting Help” later in this guide.

E-EQ-MX3MCPLUS-F-ARC

MX3 Multi-Charger Plus User’s Guide

Page 16

10

Setup

Setup •

Ensure that the location you choose for the charger/analyzer is well ventilated.

•

Place the charger/analyzer on a horizontal, hard surface.

•

Plug the power cord into a properly grounded outlet.

•

On initial power-up, all 5 pocket LEDs will light yellow for a few seconds.

The Charge Pockets

Figure 3 Charge Pocket Components 1.

Battery Charging Pocket

2.

Retaining Pins

3.

Battery Charger Contacts

4.

LED Indicator

MX3 Multi-Charger Plus User’s Guide

E-EQ-MX3MCPLUS-F-ARC

Page 17

11

Setup

The Charge/Analyze Pocket

Figure 4 Analyze Pocket Components 1.

Battery Charging/Analyzing Pocket

2.

Battery Multi-Charger Plus Contacts

3.

Retaining Pins

4.

LCD Screen

5.

Dome Switch

6.

LED Indicator

When a battery pack is inserted into the charger/analyzer pocket, press the analyze dome switch within 15 seconds to start the battery pack analysis. The analysis process ends with the battery fully charged. If the dome switch is not pressed, the battery pack is charged, but not analyzed. The LCD screen indicates the status of the charger/analyzer pocket. During battery analysis, the LCD screen displays the word “ANALYZE” plus an indication of the progress of the analysis (CHARGE, DISCHARGE or READY). If the battery is only being charged, the LCD screen only displays “CHARGE” or “READY”. Please refer to “Interpreting the LCD Screen” later in this guide for more details.

E-EQ-MX3MCPLUS-F-ARC

MX3 Multi-Charger Plus User’s Guide

Page 18

12

Using the Charge Pockets

Using the Charge Pockets There are four charging pockets on the Multi-Charger Plus. The Multi-Charger Plus charges each battery pack in less than four hours.

Placing the Battery Pack into the Multi-Charger Plus Orienting the Battery Pack Caution!

!

It is important that battery pack is inserted into the charging pocket correctly. Inserting the battery incorrectly could result in damage to the battery pack or the charger/analyzer.

When preparing the battery pack for insertion into the charger pocket, hold it with the Back (the side with only three metal contacts and grooved surface) upward, and the Top (the side with the metal retaining clip) to the left. The Front (the side with the six contacts and the smooth surface) will face downwards, into the charging pocket.

Inserting the Battery Pack Lower the battery pack straight into the battery charger pocket and push it down firmly until the retaining clip catches on the retaining pins.

Figure 5 Battery Charger Pocket Insertion

Caution!

!

Do not “slam” or slide the battery pack into the charger/analyzer. Damage may result.

MX3 Multi-Charger Plus User’s Guide

E-EQ-MX3MCPLUS-F-ARC

Page 19

Using the Charge/Analyze Pocket

13

Using the Charge/Analyze Pocket The charge/analyze pocket can be used to: •

Charge a battery pack in less than four hours.

•

Analyze a battery pack, ending with the battery pack fully charged, in less than ten hours.

Placing the Battery Pack into the Multi-Charger Plus Orienting the Battery Pack Caution!

!

It is important that battery packs are inserted into the charging/analyzing pocket correctly. Inserting the battery incorrectly could result in damage to the battery pack or the charger/analyzer.

When preparing the battery pack for insertion into the charger/analyzer pocket, hold it with the Back (the side with only three metal contacts and grooved surface) upward, and the Top (the side with the metal retaining clip) to the left. The Front (the side with the six contacts and the smooth surface) will face downwards, into the charging/analyzing pocket.

Inserting the Battery Pack Lower the battery pack straight into the battery charger/analyzer pocket and push it down firmly until the retaining clip catches on the retaining pins.

Figure 6 Battery Charger/Analyzer Pocket Insertion Caution!

!

Do not “slam” or slide the battery pack into the charger/analyzer. Damage may result.

E-EQ-MX3MCPLUS-F-ARC

MX3 Multi-Charger Plus User’s Guide

Page 20

14

Using the Charge/Analyze Pocket

Analyze Dome Switch Press the Analyze dome switch within 15 seconds of inserting the battery to start the analysis process.

Figure 7 LCD Display and Dome Switch If the dome switch is not pressed, the battery will be charged, but not analyzed. When the switch has been pressed, the LCD will display “ANALYZE” plus an indication of the progress of the analyze process. Please see “Interpreting the LCD Screen”, later in this guide for more information.

MX3 Multi-Charger Plus User’s Guide

E-EQ-MX3MCPLUS-F-ARC

Page 21

Progress Monitors

15

Progress Monitors The Multi-Charger Plus indicates the status of a battery pack with an LED located below each pocket. In addition, the charge/analyze pocket has an LCD screen providing additional information on the battery in that pocket.

Interpreting the LEDs Each pocket on the Multi-Charger Plus has an LED. The LED located at the base of each pocket communicates the status of the charge operation. Note:

On initial power-up, all five pocket LEDs will light yellow for a few seconds.

RED - on any pocket Continuous

Battery pack -

Charging (any charge pocket). Charging or analyzing (charge/analyze pocket).

Flashing

Battery pack fault or failure. Battery charger timeout period expiration.

RED FLASHING - on every pocket Battery charger fault or failure.

GREEN - on any pocket Continuous

Battery pack charge complete - Ready.

YELLOW - on any pocket Continuous

Battery pack temperature is out of range - Standby.

NO LIGHT - on a pocket No battery pack installed. Defective or damaged battery pack or charger. Refer to Troubleshooting Guide.

NO LIGHT - on every pocket No battery packs installed. No power applied to the Multi-Charger Plus.

E-EQ-MX3MCPLUS-F-ARC

MX3 Multi-Charger Plus User’s Guide

Page 22

16

Progress Monitors

Interpreting the LCD Screen The charge/analyze pocket utilizes an LCD screen to display the status of the charge or analyze operation. The LCD screen is located to the right of the charge/analyze pocket. Additional information may be displayed including voltage, capacity and battery fault information, as appropriate.

Charge Only When a battery is in the charge/analyze pocket and the analyze dome switch has not been pressed, the battery is charged. The charge process requires less than 4 hours.

CHARGE

11.2V Figure 8 LCD Screen, Charge Only The LCD indicates: •

The battery is charging (CHARGE).

•

The battery voltage under charge (11.2VDC). The voltage can vary from 9.0VDC to 12.7VDC.

MX3 Multi-Charger Plus User’s Guide

E-EQ-MX3MCPLUS-F-ARC

Page 23

Progress Monitors

17

Analyze – Initial Charge When a battery is in the charge/analyze pocket and the analyze dome switch has been pressed within 15 seconds of inserting the battery, the analyze process is started. The first step of the analysis process is to charge the battery, which takes approximately 3 hours.

CHARGE 1 ANALYZE

11.2V

Figure 9 LCD Screen, Analyze, Initial Charge The LCD indicates: •

The battery is charging (CHARGE).

•

This is the first charge cycle in the analyze process (1).

•

The battery is under analysis (ANALYZE).

•

The battery voltage under charge (11.2VDC). The voltage can vary from 9.0VDC to 12.7VDC.

E-EQ-MX3MCPLUS-F-ARC

MX3 Multi-Charger Plus User’s Guide

Page 24

18

Progress Monitors

Analyze – Discharge The next step in the analysis is the automatic discharging of the battery pack. The discharge requires 1.5 to 4 hours.

DISCHARGE

1120mAh

1 ANALYZE

10.2V

Figure 10 LCD Screen, Analyze, Discharge The LCD indicates: •

The battery is discharging (DISCHARGE).

•

This is the first (and only) discharge cycle (1).

•

The battery is under analysis (ANALYZE).

•

The battery capacity as measured during the discharge (1120mAh).

•

The battery voltage under discharge (10.2VDC). This can vary from 9.0VDC to 12.7VDC.

For information on battery capacity, please refer to “Battery Capacity” later in this manual.

MX3 Multi-Charger Plus User’s Guide

E-EQ-MX3MCPLUS-F-ARC

Page 25

Progress Monitors

19

Analyze – Final Charge The final step in the analysis process is to recharge the battery pack after it is fully discharged. The final charge requires about 2.5 hours.

CHARGE

1310 mAh

2 ANALYZE

11.2 V

Figure 11 LCD Screen, Analyze, Final Charge The LCD indicates: •

The battery is charging (CHARGE).

•

This is the second and final charge (2).

•

The battery is under analysis (ANALYZE).

•

The battery capacity measured during the analysis (1310mAh). This is an example and can vary depending on the battery pack’s maximum capacity.

For information on battery capacity, please refer to “Battery Capacity” later in this guide

E-EQ-MX3MCPLUS-F-ARC

MX3 Multi-Charger Plus User’s Guide

Page 26

20

Progress Monitors

Ready The Ready indicator is displayed at the end of the charge only or the analyze process. After the charge only process, the screen indicates the battery pack’s voltage.

READY

12.2V

Figure 12 LCD Screen, Charge Only, Battery Ready The LCD indicates: •

The charging is complete and the battery is ready for use (READY).

•

The battery voltage after charge (12.2VDC). This reading can vary between 10.2VDC and 12.6VDC.

After the analyze process, the screen displays the battery pack’s voltage and capacity.

1400mAh ANALYZE READY

12.2V

Figure 13 LCD Screen, Analyze, Battery Ready The LCD indicates: •

The battery was under analysis (ANALYZE).

•

The process is complete and the battery is ready for use (READY).

•

The battery capacity as it is measured during the analysis (1400mAh).

•

The battery voltage after charge (12.2VDC). This can vary from 12.0VDC to 12.7VDC.

MX3 Multi-Charger Plus User’s Guide

E-EQ-MX3MCPLUS-F-ARC

Page 27

Progress Monitors

21

Battery Capacity Compare the mAh reading obtained at the end of the analyze process with the battery pack’s specified capacity. If the analysis indicates a value equal to or greater than the specified capacity, the battery pack is at 100% capacity. A battery pack with less than 80% capacity provides a significant reduction in the length of time it can power the unit.

LXE Battery Pack Part Number

156213-0001 2381A376BATT1600

158224-0001 MX3A378BATT and 159922-0001 MX3A380RFIDBATT

Construction

Lithium Ion

Lithium Ion

Specified Capacity

1400mAh

1800mAh

80% of Specified Capacity

1120mAh

1440mAh

Battery Fault On rare occasions, the charge or analysis process may fail. If this occurs, note the information on the LCD screen. If the problem cannot be resolved from the troubleshooting information in the Appendix, please contact LXE Customer Support.

DISCHARGE

E04

1 ANALYZE BAT. FAULT

11.2V

Figure 14 LCD Screen, Battery Fault The LCD indicates: •

The process when the fault occurred (DISCHARGE; 1; ANALYZE). In this case, the fault occurred during the discharge cycle of the analyze process.

•

A battery fault has occurred (BAT. FAULT).

•

An error message indicating the nature of the fault (E04). Please review the Appendix or contact customer support for more information on the error code.

•

The current battery voltage (11.2VDC).

Error Message

Cause

E01 E02 E03 E04

E-EQ-MX3MCPLUS-F-ARC

Soft start rate incorrect Soft start not ready Battery open circuit

Explanation Power supply under-voltage Battery over-voltage Timeout 90 minute timeout Discharge rate incorrect

MX3 Multi-Charger Plus User’s Guide