The text of a manual · part 11 of 12
MX1 Cradle Reference Guide: Storage/Charging/Communication Options for the LXE 2330, 2335 and MX1: Chapter 5 Battery Pack Chargers
Pages 89 to 96 of 100, from MX1 Cradle Reference Guide: Storage/Charging/Communication Options for the LXE 2330, 2335 and MX1
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the LXE MX1 Dock
Page 89
Chapter 5 Battery Pack Chargers Introduction The LXE publication “Getting the Most from Your Batteries” is available on the LXE Manuals CD and is a single-source guide to battery management. The document contains information about battery recharging, conditioning, and other pertinent issues, portions of which are duplicated in this chapter. Attention: The MX1 Intrinsically Safe device battery pack is NOT compatible with these battery pack chargers. The battery pack may be damaged if placed in an unauthorized MX1-IS battery charger/analyzer. The MX1-IS keypad is bright blue in color. MX1 I-Safe
Handling Batteries Safely Never dispose of a battery in a fire. This may cause an explosion. Do not replace individual cells in a battery. Be careful when handling NiMH batteries. If a battery is broken or shows signs of leakage do not attempt to charge it. Dispose of it using proper procedures.
Caution:
Nickel-based cells contain a chemical solution which burns skin, eyes, etc. Leakage from cells is the only possible way for such exposure to occur. In this event, rinse the affected area thoroughly with water. If the solution contacts the eyes, get immediate medical attention.
Caution:
NiMH batteries are capable of delivering high currents when accidentally shorted. Accidental shorting can occur when contact is made with jewelry, metal surfaces, conductive tools, etc., making the objects very hot. Never place a battery in a pocket or case with keys, coins, or other metal objects.
Battery Warning Messages on Computers Many LXE battery operated units have been programmed to either display a warning message and/or emit distinctive beeps when battery capacity has fallen to a pre-determined level. The warning messages displayed on the screen may be similar to the following: Low Battery Warning Replace Battery Now Critically Low System Will Power Off In n Seconds
E-EQ-MX1DKRG-B-ARC
MX1 Cradle Reference Guide
Page 90
82
Battery Pack Chargers Do not ignore the warnings. The messages are displayed to warn you that the battery must be replaced or data will be lost. Follow the instructions displayed on the screen or listed in the respective equipment’s reference guide. The instructions are directed toward proper unit shutdown and battery replacement.
Optional Clip-on Portable Charger for the 2335 and MX1 The 2335 and MX1 Battery Pack can be fully charged using the Clip-on Portable Charger. A complete recharge of a dead main battery with the mobile device in an Off state will take 8 hours. Charge only at ambient temperature above 32°F / 0°C.
1. Charging LED 2. Power LED 3. Catch pins 4. Spring loaded arms 5. Power Jack connector
Figure 5-1 Clip-on Portable Charger Note:
The unit will not operate correctly on charger power without a battery installed in the mobile device.
The Clip-on Portable Charger must be powered by one of the following: • Cigarette Lighter Adapter • Power Supply, External, AC, US • Power Supply, External AC, International How To Snap the Clip-on Portable Charger to the base of the mobile device by aligning the catch pins with the notches in the Battery Door. Plug the Wall Mount or the Cigarette Lighter adapter into a power source before connecting the Power Jack to the Clip-on Portable Charger. Remove the Clip-on Portable Charger from the mobile device by depressing the spring loaded arm at the base of the module. Then remove the AC adapter from its power source.
Clip-on Portable Charger LEDs The green Power LED on the Clip-on Portable Charger indicates voltage is present in the charger. The yellow Charging LED indicates the battery is being charged. When a battery is present in the mobile device, the Charging LED is always lit. The intensity of the Charging LED indicates the following states: Bright
MX1 Cradle Reference Guide
The Portable Charger is using its high charge rate. The charger detected a battery low state and is charging the battery until a full battery condition is detected.
E-EQ-MX1DKRG-B-ARC
Page 91
Battery Pack Chargers
83
Dim
The Portable Charger is using its low charge rate. The charger detected a full battery or that the battery only requires “topping off.”
Unlit
There is no battery in the mobile device. No charge rate is being applied. The indicator does NOT turn off when charging is complete.
Main Battery Pack Charger for the Mobile Device
Figure 5-2 Main Battery Pack Chargers / Analyzers Charges NiMH Battery Pack 2330A381BATT1500 and 6 Unit Charger/Analyzer 2330A378CHGR6WW 2330A380BATT1500 3 Unit Battery Analyzer 2330A379ANLZR3WW Power Supply, AC, US 2335A301PSACUS Power Supply, AC, International 2335A302PSACWW The charger/analyzer used with the NiMH batteries for the 2330, 2335 and MX1 have from three to six battery cups. There is one Test or Maintenance station, which is the last slot on the far right. This station will ultimately charge a battery. Mounted below the Analyzing Station is the LED Information Center and three dome switches, labeled Condition, Discharge and Analyze.
Figure 5-3 1500 mAh (NiMH) Main Battery 1.
Battery Contacts
2.
Positioning Key
Named for the Nickel-Metal hydride construction – Main Battery packs power the 2330, 2335 and the MX1 (except MX1-IS). The minimum battery life before replacement is 300 – 500 charge/discharge cycles.
E-EQ-MX1DKRG-B-ARC
MX1 Cradle Reference Guide
Page 92
84
Battery Pack Chargers
1.
Battery Adapter or Charging Cup
2.
Test Station of Maintenance Station
3.
Function Indicators
4.
LCD Information Center
Figure 5-4 Six Cup Charger/Analyzer
Figure 5-5 Back View of a Charger/Analyzer Note:
The power supply cord is the main disconnect device.
The rear panel contains some or all of these features: • A/C cable receptacle. • Protection provided by either a 2 amp SLO BLO fuse or a 1 or 2 amp circuit breaker. • Power or On/Off switch. • Fan for temperature control. LXE multi-unit charger/analyzers perform the same four functions: Charge, Discharge, Analyze and Condition. The function results are displayed on the LCD Information Center or the indicator strip under each battery adapter or cup. Display
Description
DISCHARGE
The analyzer is discharging the battery.
CHARGE
The analyzer is charging the battery.
CONDITION
The analyzer fully charges, discharges, and recharges the battery three times and displays the capacity of the battery. At the end of the three-step process, the analyzer charges the battery.
MX1 Cradle Reference Guide
E-EQ-MX1DKRG-B-ARC
Page 93
Battery Pack Chargers
85
Display
Description
1.2.3
Cycle numbers indicating which cycle the analyzer is currently performing in the Conditioning of the battery.
ANALYZE
The analyzer fully charges, discharges, and recharges the battery once and displays the capacity of the battery.
BAT.FAULT
The battery is shorted (contains 2 volts or less) or the battery has not reached 6 volts for a 6 cell battery (or 5 volts for a 5 cell battery) after fifteen minutes of the Charge cycle.
READY
The battery is ready for use.
mAh
The capacity reading of the battery.
V
The voltage of the battery.
Note:
Do not remove the battery, or power the analyzer on and off, in the middle of a process. The process will start at the beginning when power, or the battery, is restored.
E-EQ-MX1DKRG-B-ARC
MX1 Cradle Reference Guide
Page 94
86
Battery Pack Chargers
Using a 3 or 6 Bay Charger/Analyzer Place the charger/analyzer on a flat surface, near an AC power supply and in a location that is protected from passing vehicles or falling objects. Check all batteries for cracks, chips or leaks before placing in the charger/analyzer. If the battery is damaged it cannot be used in the charger/analyzer and must be discarded properly. Verify that the battery type is the correct type for the selected charger/analyzer – NiCad batteries in NiCad chargers, NiMH batteries in NiMH chargers, Li-Ion batteries in Li-Ion chargers.. Note:
When the battery does not fit snugly in the battery charging cup, the battery is the incorrect type for that particular analyzer and must be removed.
Getting Started If the unit is unplugged, confirm that the charger/analyzer power switch is in the Off position. The power switch is on the rear panel. The “I” indicates the On position and the “O” indicates the Off position. If the unit has a rear panel voltage selector switch, set the switch to match the line voltage it will be receiving. Connect the AC plug from the rear of the analyzer to a convenient and appropriate (check the user guide or the voltage label on the analyzer) 115VAC or 220/240VAC outlet. Some analyzers require 220/240VAC only.
Power On Note:
Remove all batteries from the charger/analyzer before turning the unit on.
Press the rear panel Power Switch to the On position (On “I”, Off “O”). When powered on, the LCD Information Center illuminates and, within the first 5 seconds, displays diagnostic information gathered from the charger/analyzer.
Figure 5-6 Sample Diagnostic Display When the diagnostic cycle is complete, the LCD screen is blank and the charger/analyzer battery stations are in “Standby” mode, ready to begin charging batteries. The “V” or volts message should increase during the charging cycles and decrease during the discharge cycles. During mode operations, the mAh display continuously tracks the depleted energy or capacity of the battery. The message displays the capacity in increasing 11 mAh increments, during the discharge cycles. Note:
When screens are blank, analyzer is ready for batteries.
MX1 Cradle Reference Guide
E-EQ-MX1DKRG-B-ARC
Page 95
Battery Pack Chargers
87
Insert Battery
Figure 5-7 Battery Pack and Charging Cup 1
Battery Adapter or Charging Cup
2
Battery Contacts on Battery
3
Battery Contacts in Adapter or Charging Cup
Place the battery into a charging cup. Be certain the polarity is correct and the battery contacts align with the adapter contacts. When using a charger/analyzer for NiMH batteries, and the battery is installed in the Test or Maintenance station, the letter “H” is displayed during the Charge mode only.
Select A Function Do not remove the battery, or power the analyzer on and off, in the middle of a process. The process will start at the beginning when power, or the battery, is restored. When the first part of a process is Discharge, the available capacity in the battery will be discharged again. Use This Mode
When You …
Condition
Prepare a new battery for use or restore a deficient battery to maximum available power.
Charge
Want to fast charge a battery and maintain it’s full charge capacity via trickle charge until needed.
Analyze
Need to measure battery capacity. This process first discharges then charges the battery. The measured result can be compared against the battery specs.
Discharge
Want to verify the performance of another battery charger or check for excessive “stand-loss.”
Note:
Batteries are Conditioned and/or Analyzed in the Test or Maintenance station only.
E-EQ-MX1DKRG-B-ARC
MX1 Cradle Reference Guide
Page 96
88
Battery Pack Chargers
AC Adapters for 3 and 6 Bay Battery Chargers US AC Wall Adapter
Figure 5-8 US AC/DC 12V Power Supply Operating Temperature
32°F to 104°F (-0°C to 40°C)
Storage Temperature
-22°F to 140°F (-30°C to 60°C)
Operating Humidity
Up to 90% non-condensing at 104°F (40°C)
International AC Adapter
Figure 5-9 International AC/DC 12V Power Supply Operating Temperature
32°F to 104°F (-0°C to 40°C)
Storage Temperature
-22°F to 140°F (-30°C to 60°C)
Operating Humidity
Up to 90% non-condensing at 104°F (40°C)
MX1 Cradle Reference Guide