Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 8

6200 Equipment Reference Guide: Chapter 2 LXE Legacy Terminals, pages 27 to 34

Pages 27 to 34 of 74, from 6200 Equipment Reference Guide

The original document is the PDF (1.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the LXE 6210

Page 27

Supported Barcode Symbologies

21

Standard Range (SR) The minimum range for a standard range scanner is 1 inch (2.54cm) and the maximum is 3 feet or 36 inches (91.44cm). Sample applications include receiving; shipping; hospital patient identification; time and attendance; and reading barcoded menus. The scanners in this class include the 5310, 5380, and the LS3000 SR. Long Range (LR) The minimum range for a long range scanner is about 6 inches (15.24cm) and the maximum is 6 feet or 72 inches (1.83m). Sample applications include picking, receiving, and reading rack labels. The scanners in this class include the 5350 and the LS3000 LR. Advanced Long Range (ALR) The minimum range for an advanced long range scanner is 2 feet (61cm) and the maximum range is 8 feet (2.44m). Sample applications include picking, shipping, cross-docking, receiving, or any application where the operator wants to read barcode labels from a vehicle. Some of these scanners also read labels made from retro-reflective materials. These are special labels that give some ALR scanners ranges up to 20 feet (6.1m). The scanners in this class include the 5340 and the LS3000 ALR. Extra (Extended) Long Range (XLR) The minimum range for an extra long range scanner is 3 feet (91.44cm) and the maximum range using conventional paper labels is 20 feet (6.1m). Retro-reflective labels allow certain types of XLR scanners to read from as far as 35 feet (10.67m) away. Sample applications include any type of operation using bulk storage locations. Barcode labels can be hung from the ceiling above the bulk storage locations and can be read using these XLR scanners. The scanners in this class include the 5370, 5390, and the LS3000 XLR. High Visibility (HV) The minimum range for a high visibility scanner is 1 inch (2.54cm) and the maximum range is 2 feet (61cm). Sample applications include any operation where you must read a barcode label through glass or in the sunshine. These scanners were made to read a vehicle identification number (VIN) barcode label, which is commonly found on the dashboard of an automobile. Scanners in this class include the 5320 and LS3000 HV. High Density (HD) The minimum range for a high density scanner is 2 inches (5.08cm) and the maximum range is 10 inches (25.4cm). These scanners were made to read very small barcode labels. Sample applications for these scanners include reading labels printed on printed circuit boards, test tubes, and other small components. Scanners in this class include the 5330 and the LS3000 HD.

Supported Barcode Symbologies The following describes the barcodes that LXE supports. See the Hardware Setup Menus in the “Terminal Setup” chapter of the specific terminal emulation guide for instructions on how to configure the LXE terminal to use these different barcode symbologies. Code 39 (C39) Standard Code 39 encodes capital letters, numbers and a few special characters. The LXE terminal can also decode Extended Code 39, which includes the complete ASCII character set. You can specify an optional check character for use with either standard or extended C39.

E-EQ-6200EQRG-B-ARC

6200 Equipment Reference Guide

Page 28

22

Supported Barcode Symbologies

Discrete 2 of 5 (C25) Discrete 2 of 5 is a numeric only code that has been superseded by Interleaved 2 of 5, which has the same decode capabilities but uses a much smaller space. Interleaved 2 of 5 (I25) Interleaved 2 of 5 has the same decode capabilities (numeric only) as Discrete 2 of 5, yet uses a much smaller space by interleaving two characters. I25 requires an even number of characters and inserts a leading zero when it encounters an odd number of characters in a barcode label. A major problem with Interleave 2 of 5 is the potential for partial reads. For example, the terminal could decode barcode 123456 as 3456. IL1 and IL2 IL1 and IL2 enable you to set two distinct lengths for the Interleaved 2 of 5 code. If IL1 is set to 6 and IL2 to 8, the terminal will not decode Interleaved 2 of 5 barcode labels with character lengths of 2, 4, 10, or 12. To read Interleaved 2 of 5 codes of more than two lengths, you must set IL1 and IL2 to zero, which enables the terminal to read any length of Interleaved 2 of 5 codes. MSI Plessey (PLS) MSI Plessey has 3 variant codes: MSI, Telxon, and Anker. LXE's PLS parameter reads all of the variants and treats all of the check characters the same. Code 11 (C11) Code 11 is used to satisfy specialized requirements for very high density, discrete barcode labels capable of encoding numeric data. C11 is so named because it can represent 11 different characters (10 digits and a dash). Data security is enhanced by using one or more check digits. It is recommended that the X dimension of Code 11 barcodes be 7.5 mils. This limits the scanning range to about 1 foot (30.5cm) at its maximum (with VLD scanners). Code 128 (128) Code 128 is so named because it was the first decode of the complete 128 ASCII character set. Code 128 claims to be the most compact, complete, alphanumeric symbology available. LXE terminals can decode 128A, 128B, 128C, EAN-128, and 128 Auto. UPC The Uniform Product Code is the most widely used and recognized barcode in the world. The UPC is a numeric-only barcode. LXE can autodiscriminate between the UPC-A and UPC-E versions of the code, which are 12 and 6 digits respectively. On a typical 12 digit code, the first number is an item code, the next five digits represent the manufacturer's ID number, the next five digits represent the product ID number, and the last digit is a check digit. EAN The European Article Numbering code is derived from the UPC code, and is used mainly on the European Continent. There are several versions of EAN. LXE supports the reading of EAN-8 and EAN-13, which are eight and 13 digit codes, respectively. The basic difference between EAN and UPC is that EAN uses the first two digits of the code to identify the product's country of origin. LXE can autodiscriminate between EAN-8 and EAN-13.

6200 Equipment Reference Guide

E-EQ-6200EQRG-B-ARC

Page 29

Using the Laser Scanner

23

Using the Laser Scanner Non-contact moving-beam scanners use laser light for illumination. The beam automatically moves (scans) when the trigger is pulled. The scan rate may be more than 40 times per second. How To Point the laser aperture at a barcode and press the key or button that activates the laser. •

A red light emitting diode (LED) indicates the unit is actively scanning.

•

The Scan LED turns green to indicate when a barcode was successfully read (a good scan). Do not pour, spray, or spill any liquid on the scanner. The Barcode Scanner contains the circuitry, scanning motor and laser. Handle with appropriate care.

Aiming the Barcode Scanner Aim the scanner away from you, direct it at the barcode and press the trigger to scan. The Scan LED (indicator is located directly below the display) turns red to indicate the scanner is on. Adjust the aim so that the narrow, red laser beam covers the entire length of the barcode. The scan beam must cross every bar and space on the barcode.

Correct Scan

Incorrect Scan

Incorrect Scan

Figure 2-12 Scan Beam Make sure the barcode is within the scanning range. The range of a scanner is dependent upon many outside influences including size of the barcode, quality of the barcode printing, material the barcode is printed on, and angle of the scanner beam relative to the barcode label. Any of these factors may result in having to re-scan the label from a different distance or angle.

E-EQ-6200EQRG-B-ARC

6200 Equipment Reference Guide

Page 30

24

Using the Laser Scanner

Factors That May Impact Scanner Performance The range of a scanner is dependent upon many outside influences including size of the barcode, quality of the barcode printing, material the barcode is printed on, condition of the scan lens (scratches) and angle of the scanner endcap relative to the barcode label. Any of these factors may result in having to re-scan the label from a different distance or angle.

Scanning Angle Determine the optimum distance between the scanner and the barcodes to be read. Locate the scanner so the symbols are near the middle of the range. Center the barcode in the scan beam and scan perpendicular to the barcode label. If tilt is unavoidable, try to keep the tilt percentage between 3 and 15% off perpendicular.

Barcode Quality Check the barcode for marks or physical damage e.g. ripped label, missing section, correct size for the scanner being used, etc. In general, the bigger the barcode the further the distance from which it can be read. If the barcode is smaller than the specified size for the scanner being used, the distance, in almost all cases, will shrink. Large barcodes can be scanned at the maximum distance. Hold the scanner closer to small barcodes (or with bars that are very close together). Note:

Do not position the scanner exactly perpendicular to the barcode being scanned. In this position, light can bounce back into the scanner’s exit window, and possibly prevent a successful decode.

Barcode Symbology Barcodes such as UPC codes and Code 128 are more complex than Code 39 and I 2 of 5. When attempting to get the maximum read distance possible, particularly with reflective labels, use Code 39. The use of Code 128 or other more complex symbologies will almost always result in a reduction in maximum read distance. LXE will not support scanner maximum distances when symbologies other than Code 39 are used.

Lens Damage A scratched scanner window can impact read rates and distances. Scanner lenses should be inspected frequently, particularly if scanning quality or distances get worse over time.

Ambient Lighting High ambient conditions, particularly outdoor environments, will produce enough light to somewhat “blind” the scanner. This will result in shorter read distances.

Temperature While small deviations from room temperature will have no impact on scanner performance, severe conditions like those found in freezers will have a negative impact on both the distance scanners can read and the speed the read is acquired.

6200 Equipment Reference Guide

E-EQ-6200EQRG-B-ARC

Page 31

Batteries

25

Batteries Most non-LXE battery charger/analyzer manufacturers include a product user manual with their battery charger/analyzer or batteries. Use the information in this section as an additional source of information to the manufacturer's guide. LXE strongly urges you to heed the cautions and warnings contained within the manufacturer's user guide. Reference Manual : E-INF-BATTERY[Revision] “Getting the Most From Your Batteries”

Battery Construction Types LXE offers three types of main batteries or Main Battery packs: • • •

Nickel-Cadmium (NiCad) batteries. Nickel-Metal-Hydride (NiMH) batteries. Lithium-Ion (Li-Ion) batteries.

The internal backup batteries are either Lithium or NiCad, however, the backup battery (also known as a coin or button battery) is not user replaceable. The unit should be returned to LXE when the backup battery needs replacing.

NiCad Batteries Named for the Nickel-Cadmium construction – Main Battery packs power the 2100 Series, 2280, 2285, and 2315 units. Advantages: • • • •

Considerable power Tolerance for wider range of operating temperatures Lasts for more charge/discharge cycles Shorter charge time

Disadvantages: • • •

“Memory effect” necessitates periodic discharge “Stand loss” can be significant Environmentally unfriendly due to toxic metals

NiMH Batteries Named for the Nickel-Metal hydride construction – Main Battery packs power the 2280, 2285, and 2315 units. Advantages: • • •

More capacity than NiCad batteries No poisonous metals Less prone to “memory effect”

Disadvantages: • •

E-EQ-6200EQRG-B-ARC

Higher “stand loss” than NiCad batteries Longer charge time than NiCad batteries

6200 Equipment Reference Guide

Page 32

26

Batteries

Battery Types used in Legacy Equipment These are the main battery types recommended for use with LXE hand-held terminals and computers: LXE Product

Battery Type

2100 Series Terminal

800 mAh battery (NiCad).

2280 Series Terminal 2285 Series Terminal

600 mAh battery (NiCad) or 1000 mAh battery (NiMH).

2315 Terminal

850 mAh battery (NiMH) or 600 mAh battery (NiCad)

Estimated Battery Life Refer to the following list of estimated battery life for the following batteries:

LXE Product

Battery Type and Rating

Minimum Battery Life (Before Replacement)

2100 Series Terminal

NiCad 800 mAh

500 charge/discharge cycles

2280 Series Terminal 2285 Series Terminal

NiCad 600 mAh NiMH 1000 mAh

500 charge/discharge cycles 300-500 charge/discharge cycles

2315 Terminal

NiMH 850 mAh NiCad 600 mAh

300-500 charge/discharge cycles

LXE Scanner Current Requirements The barcode port on your terminal allows you to connect scanning devices to your terminal. The following table lists the current that the scanner uses while you scan: Note:

Note:

The more current a scanner requires while in use, the more it drains the life of your battery. Scanner

Current

3000 Series

125 mA

5300 Series

135 mA

8500XLR

200 mA

Scanners not in use require only a small amount of current.

6200 Equipment Reference Guide

E-EQ-6200EQRG-B-ARC

Page 33

Batteries

27

Battery Replacement Battery replacement instructions for LXE terminals and computers are fully documented in the operator or reference guides delivered with the units. Please refer to the manuals for complete instruction. If the computer supports “hot swapping” the main battery, the instructions follow. In general, the battery replacement procedures consist of the following steps: 1.

If the unit is powered on, save any work, and close running programs.

2.

Turn the unit off.

3.

Open the battery access panel or cover and remove the battery.

4.

Insert an appropriate fully charged battery, aligning the positive and negative contacts on the battery with the metal contacts in the unit.

5.

Close the battery access panel or cover.

6.

Turn the unit on.

Place the used battery in the appropriate battery charger/analyzer.

Hot Swapping the Battery If you are using a computer that supports “hot swapping” the main battery, the main battery may be replaced without powering the computer down. Refer to the computer’s operator or reference guide for complete details. The general procedure for hot swapping the main battery consists of the following steps: 1.

Save any work, and close running programs.

2.

Place the computer in suspend or standby mode.

3.

Open the battery access panel or cover and remove the battery. The computer enters critical suspend mode when the main battery is removed.

4.

The backup battery maintains data such as time and date for at least 5 minutes but does not provide power for computer operation. If the hot swap is not completed before the backup battery is depleted or the off timer expires, the computer powers off and must be rebooted after the fresh main battery is installed.

5.

Insert an appropriate fully charged battery, aligning the positive and negative contacts on the battery with the metal contacts in the unit.

6.

Close the battery access panel or cover.

7.

The computer then returns to the suspend state. Follow the appropriate action to return to the on-state and the computer is ready for use. There may be a slight delay if the radio needs to re-establish an RF connection.

E-EQ-6200EQRG-B-ARC

6200 Equipment Reference Guide

Page 34 read from a scan by OCR; it may hold reading errors

28 Batteries [pal

6200 Equipment Reference Guide E-EQ-6200EQRG-B-ARC