Page 7
Chapter 1 6200 Series System Overview Introduction This guide provides operating information for the LXE 6200 Series Terminals and related RF backbone equipment. Backbone equipment includes Network Controllers (NC) and Radio Frequency Units (RFU). Network controllers are connected to the host through the wired backbone. Radio frequency units are connected to the host wirelessly, through the network controllers. Both units use an LXE installed narrowband or 900MHz radio for wireless data communications. The terminals are portable computers capable of wireless data communications and powered by a rechargeable Nickel-Metal Hydride (NiMH) or Nickel-Cadmium (NiCd) battery pack and a lithium backup battery. The devices use an LXE installed narrowband or 900MHz radio for wireless data communications. Most devices that communicate with the host require an installed radio card and an antenna.
Legacy Terminals vs DOS Computers in a 6200 System Devices used in the LXE Legacy 6200 system (e.g. LXE 12XX vehicle mount and 22XX hand held terminals) are frequently called “LXE RF terminals.” To distinguish between the Legacy terminals and LXE certified DOS computers used in many 6200 systems (e.g. the LXE VX1 vehicle mount and MX1 hand held computers) this guide refers to LXE DOS based mobile RF devices as “DOS computers.” LXE DOS computers used in a Legacy environment usually have a 900MHz radio installed and run these LXE terminal emulators: IBM 3270, IBM 5250, ANSI and LDS. For more information on LXE DOS computers, please refer to the equipment-specific guides on the LXE Manuals CD and the LXE ServicePass website.
Obsolete Equipment The LXE Legacy RF devices, terminals, 5240/5260 Wireless Modems, 900 MHz and narrowband radios are obsolete. The information contained in this guide relating to this equipment has been made available as a courtesy to LXE's Legacy customers. Please contact your LXE customer support representative for assistance with these units or upgrade to newer models. As equipment is placed on the obsolete list (quite often due to the rapidly changing nature of the RF environment), LXE makes every effort to support, service and repair the equipment until it is no longer repairable/serviceable. Please contact your LXE representative for replacement equipment or software.
Obsolete 6200 System Equipment and Software as of June/July 2005 3270 Terminal Emulation NC/RFU - 6220, 6230, 6280, 6281 5250 Terminal Emulation Terminal - 1280, 1290, 2280, 2285, 2286, 2315 ANSI Terminal Emulation Modem - 5232, 5420, 5460 LDS I and LDS II Terminal Emulation DOS Computer - 1320, 1330, 2320, 2330 6200 Network Management Workstation (Console)
E-EQ-6200EQRG-B-ARC
6200 Equipment Reference Guide
Page 8
2
Getting Help
Getting Help LXE user guides are now available on CD and they can also be viewed/downloaded from the LXE ServicePass website. Contact your LXE representative to obtain the LXE Manuals CD or access to the LXE ServicePass website. You can also check the LXE ServicePass website for the latest manual releases. Note:
Obsolete/archived manuals are not available on the LXE Manuals CD. They are available for download from the ServicePass website only.
You can get help from LXE by calling the telephone numbers listed on the LXE Manuals CD, in the file titled “Contacting LXE”. This information is also available on the LXE website. Explanations of terms and acronyms used in this manual are located in the file titled "LXE Technical Glossary" on the LXE Manuals CD and on the LXE website.
Document Conventions ALL CAPS
All caps are used to represent disk directories, file names, and application names.
Menu|Choice
Rather than use the phrase "choose the Save command from the File menu", this manual uses the convention "choose File|Save".
"Quotes"
Indicates the title of a book, chapter or a section within a chapter (for example, "Document Conventions").
<
Indicates a key on the keyboard (for example, <Enter> ).
>
Indicates a reference to other documentation. Differences in operation or commands due to radio type. ATTENTION
Keyword that indicates vital or pivotal information to follow. Attention symbol that indicates vital or pivotal information to follow. Also, when marked on product, means to refer to the manual or operator’s guide. International fuse replacement symbol. When marked on the product, the label includes fuse ratings in volts (v) and amperes (a) for the product.
Note:
Keyword that indicates immediately relevant information.
CAUTION
Keyword that indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
WARNING
Keyword that indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
DANGER
Keyword that indicates a imminent hazardous situation which, if not avoided, will result in death or serious injury.
6200 Equipment Reference Guide
E-EQ-6200EQRG-B-ARC
Page 9
6200 System Overview
3
6200 System Overview The LXE 6200 network controller (NC) and radio frequency unit (RFU) form the backbone of a 6200 radio frequency data communication (RFDC) system. The RFU and NC provide a wireless link between your host computer and LXE radio frequency (RF) terminals.
Radio Frequency Data Communication With an LXE radio frequency data communication system you can collect data in real-time with mobile devices. Radio Frequency Data Communication (RFDC) uses radio transceivers rather than wire-linked terminals as part of the communication channel.
Network Diagrams The following illustration compares a conventional wire-linked system to a Legacy radio frequency data communication system:
IBM 3270 Host Computer
Front End Processor
Modem or Modem Eliminator
Network Media
Modem or Modem Eliminator
IBM Controller
LXE Network Controller
Hardwired Terminals
LXE Radio Frequency Unit (RFU)
LXE Radio Frequency Unit (RFU)
LXE Radio Frequency Terminals
Figure 1-1 3270 Wire Linked System and RF System The wire-linked system physically links a host computer to remote terminals with wires. This link obviously restricts the mobility of the terminal users and prevents them from moving about freely (as in a warehouse application). A radio frequency data communication system uses radios to link remote terminals to a host computer. RFDC allows terminal users to roam while communicating with a host application in real-time.
E-EQ-6200EQRG-B-ARC
6200 Equipment Reference Guide
Page 10
4
6200 System Overview
System Components RFDC System The following diagram shows a basic LXE-based radio frequency data communication system:
IBM 3270 Host Computer
Front End Processor
Network Media
Modem or Modem Eliminator
LXE Network Management Workstation (NMWS)
LXE Network Controller
LXE Radio Frequency Unit (RFU)
LXE Radio Frequency Unit (RFU)
LXE Radio Frequency Terminals
Figure 1-2 LXE Radio Frequency Data Communications System Communication Controller
An IBM device used to control and maintain long distance communication between the IBM host and remote IBM users.
Network Management Workstation
LXE-provided software running in a personal terminal and computer that enables you to interact with the network controller.
Host Computer
A computer system that runs application programs and maintains data bases.
Modem or Modem Eliminator
A device that enables the Network Controller to communicate with the host computer.
Network Controller (NC)
An LXE device that monitors and manages message flow between the host computer and the RF terminals and computers.
Radio Frequency Unit (RFU)
An LXE device that links the NC to the terminals. The RFU transmits data to and receives data from the mobile terminals and computers using radio waves.
RF Terminal
An LXE device that an operator uses to communicate with the host computer. The RF terminal transmits data to and receives data from the RFU using radio waves.
6200 Equipment Reference Guide
E-EQ-6200EQRG-B-ARC
Page 11
Network Controllers and Radio Frequency Units
5
Network Controllers and Radio Frequency Units Technical information for the devices shown in the following figure are in Chapter 5 “Technical Specifications.”
Figure 1-3 Network Controller / Radio Frequency Unit with Antenna
Figure 1-4 Type 4 Enclosure contains Radio Frequency Units
Network Controllers (NC) Sends / receives the messages coming from the wireless units to the host application and from the host application to the wireless units. A network controller is connected to the wired backbone of the 6200 network. LXE's entry level 6210 is ideally suited for smaller facilities of less than 150,000 square feet. The 6210 has an integrated radio and host connectivity for Ethernet or TokenRing. It can also support up to 32 terminals. For medium to large sized facilities, LXE's 6220 and 6230 can effectively manage up to 128 terminals. It has a maximum possible configuration of 64 network controllers and radio frequency units working together on the same network. The 6230 has an internal radio transceiver for additional RF coverage.
Features Technical specifications for network controllers are in Chapter 5 – “Technical Specifications.” 6210 Network Controller •
Integrated Radio.
•
No additional RFU support needed.
•
Supports up to 32 terminals.
•
Designed for smaller systems where the controller can be located in the coverage area.
•
Supports a local or remote antenna.
•
The compact design of the 6210 integrates host connectivity with radio capabilities into a single unit thus eliminating the need for an external Radio Frequency Unit.
•
The 6210 is designed for use in a fairly clean environment without high dust, moisture or vibration exposure.
E-EQ-6200EQRG-B-ARC
6200 Equipment Reference Guide
Page 12
6
Network Controllers and Radio Frequency Units
6220 Network Controller •
External Radio Frequency Unit.
•
Supports up to 128 terminals.
•
Supports up to 60 RFUs.
•
System designed for locations where Network Controller needs to be remote from the coverage.
•
Designed for use in medium or large sized facilities.
•
Manages up to 128 terminals and up to 60 RFUs interconnected on an Ethernet or Token Ring backbone.
6230 Network Controller •
Integrated Radio.
•
Can be configured without RFUs for later system expansion.
•
Designed for systems where the NC can be located in the coverage area.
•
Supports a local or remote antenna.
•
Designed for use in medium to large sized facilities.
•
The 6230 supports up to 128 separate terminals and up to 59 Radio Frequency Units in addition to it’s integrated radio.
6200 Equipment Reference Guide
E-EQ-6200EQRG-B-ARC
Page 13
Network Controllers and Radio Frequency Units
7
Radio Frequency Units (RFU) A wireless RF device that passes messages coming from the wireless units to the Network Controller and then passes the messages coming from the Network Controller to the wireless units. An RFU is not connected to the wired backbone of the 6200 network.
NEMA Type 4 Enclosure The LXE 6280 radio frequency unit extends RF coverage into isolated departments or different buildings without the need for a separate network controller. The 6280 functions as an industry standard Ethernet or Token-Ring network node. The LXE 6281 is a NEMA 4 certified radio frequency unit that can withstand water and wind blown dust. The 6281 is excellent for outdoor coverage and also has a heater option for cold temperature operations down to -22° F.
Features Technical specifications for network controllers is contained in Chapter 5 – “Technical Specifications.” 6280 Radio Frequency Unit •
Same hardware design as 6210/6220/6230 Network Controllers.
•
Only Half-Duplex RF (Send/Receive Sequential).
•
Ethernet or Token Ring interconnect to the NC.
•
Provides the RF interface between the wireless terminals and the Network Controller.
•
Designed to be used when the coverage area is separate from the location of the Network Controller.
•
Similar in external design to 6200 series Network Controllers and shares many common internal components.
6281 Radio Frequency Unit •
Same functional design as the 6280 RFU.
•
NEMA enclosure.
•
Equipped with a heating element for operation in cold environments.
•
A radio frequency unit in a weatherproof, heated NEMA enclosure.
•
It is designed to be installed outdoors.
•
Can be used in conjunction with either a 6220 or 6230 Network Controller.
E-EQ-6200EQRG-B-ARC
6200 Equipment Reference Guide
Page 14
8
Components
Components NC and RFU Front Panel Components The 6210, 6220, 6230, 6280, and 6281 share most of the same front panel components.
Figure 1-5 NC Front Panel
MEMORY CARD
The MEMORY CARD slot of the 6210, 6220, and 6230 accepts a Personal Computer Memory Card Industrial Association (PCMCIA) memory card to download software into Flash RAM .
CONSOLE TX
The CONSOLE TX LED lights when the 6200 transmits data to the network management workstation.
CONSOLE RX
The CONSOLE RX LED lights when the 6200 receives data from the network management workstation.
HOST TX
The HOST TX LED lights when the 6210, 6220, or 6230 transmits data to a nonTCP/IP host.
HOST RX
The HOST RX LED lights when the 6210, 6220, or 6230 receives data from a non-TCP/IP host.
HOST RTS
The HOST RTS LED lights when the 6210, 6220, or 6230 requests to send data to a non-TCP/IP host.
HOST CTS
The HOST CTS LED lights when a non-TCP/IP host determines that the 6210, 6220, or 6230 is clear to send data.
RF TX
The RF TX LED is always lit on a 6210, 6230, 6280, or 6281.
RF RX
The RF RX LED is always lit on a 6210, 6230, 6280, or 6281 running narrowband. This LED may not be visibly lit in a spread spectrum application.
SYSTEM RUN
The SYSTEM RUN LED blinks on and off when the 6200 firmware is operating.
SYSTEM ALARM
The SYSTEM ALARM LED lights when an alarm (fault) condition is detected.
6200 Equipment Reference Guide
E-EQ-6200EQRG-B-ARC
Page 15
Components
9
Ethernet 6200 Rear Panel Components
Figure 1-6 Ethernet 6200 Rear Panel Components Antenna Connector
Connects an RF antenna to the 6210, 6230, or 6280. An antenna connector is not present on a 6220.
Power Panel
Connects an AC power source to the 6200 product and switches power to the 6200.
Ethernet Ports
The Ethernet ports (THIN NET, AUI, and TPE) enable you to use different types of cable to connect the 6200 product to the Ethernet.
THIN NET
The THIN NET port connects to Thinnet cable, as defined by the IEEE 802.3 10Base2 specification. Thinnet is RG 58A/U coaxial cable.
AUI
The Attachment Unit Interface (AUI) port connects to a transceiver that connects to the IEEE 802.3 standard10Base5 backbone coaxial cable, also known as thick Ethernet.
TPE
The Twisted Pair Ethernet (TPE) port is a RJ-45 modular telephone connector that connects to IEEE 802.3 standard 10BaseT twisted pair cable. Note: Early versions of the Ethernet 6200 series did not feature a TPE port. A twisted pair connection is made with an adapter attached to the AUI connector.
RXD
The RXD (Receive Data) LED lights when the 6200 series device receives data from the Ethernet.
TXD
The TXD (Transmit Data) LED lights when the 6200 series device transmits data to the Ethernet.
ID Tag
A paper tag printed with two sets of numbers. The upper set is the LXE part number; the lower set is the hex representation of 3 bytes of the 48-bit universally-administered hardware address that is burned into a prom on the interface board.
AUX Port
An RS-232 (DTE only) connection between a non-TCP/IP host and the 6200 series network controllers. A 3270 or 5250 V.35 connection is achieved using the AUX port and an external converter. Connection to a 3270 host on a Token-Ring is achieved from the AUX port with an external converter. Connection to a 5250 host on a Token-Ring requires two external converters.
Console Port
Connects to the network management workstation.
E-EQ-6200EQRG-B-ARC
6200 Equipment Reference Guide
Page 16
10
Components
Token-Ring 6200 Rear Panel Components
Figure 1-7 Token-Ring 6200 Rear Panel Components Antenna Connector
Connects an RF antenna to the 6210, 6230, or 6280. An antenna connector is not present on a 6220.
Power Panel
Connects an AC power source to the 6200 product and switches power to the 6200.
Token-Ring Ports
The ports (UTP and STP) on the rear panel of the 6200 device enable you to use different types of cable to connect the 6200 network controllers and RFUs to the Token-Ring. UTP
The Unshielded Twisted Pair (UTP) port is an RJ-45 modular telephone connector that connects to IBM type 3 or EIA/TIA category 3, 4, or 5 unshielded twisted pair cable.
STP
The Shielded Twisted Pair (STP) port is a D-9 connector that connects to IBM type 1, 2, 6, or 9 shielded twisted pair cable.
UTP-STP Selector
A switch that enables you to select the correct port.
ID Tag
A paper tag printed with two sets of numbers. The upper set is the LXE part number; the lower set is the hex representation of 3 bytes of the 48-bit universally-administered hardware address that is burned into a prom on the interface board.
RDY
The RDY (Ready) LED remains on during normal operation of the 6200 series device.
ERR
The ERR (ERROR) LED lights momentarily when the 6200 series device is turned on. The ERR LED remains on when the device is disconnected from the Token-Ring and remains off during normal operation.
AUX Port
An RS-232 (DTE only) connection between a non-TCP/IP host and the 6200 series network controllers. A 3270 or 5250 V.35 connection is achieved using the AUX port and an external converter. Connection to a 3270 host on a Token-Ring is achieved from the AUX port with an external converter. Connection to a 5250 host on a Token-Ring requires two external converters.
Console Port
Connects to the network management workstation.
6200 Equipment Reference Guide
E-EQ-6200EQRG-B-ARC
Page 17
Omni Antennas
11
Omni Antennas LXE 6200 devices use a 0db gain Omnidirectional antenna exclusively. Omnidirectional antennas have a spread out coverage area that radiates and receives from all directions. Coverage area is not consistant but tends to increase and decrease depending on where coverage is being measured around the antenna. Omni directional antennas are useful for extending the range of an access point allowing client access from greater distances. They also can be used for setting up point to multipoint links (many directionals pointed at your high gain omni). The omni directional antenna has a radiation pattern shaped like a doughnut or pancake. The power that would be transmitted in the upward and downward directions are instead aimed out the side. The more gain the antenna has, the flatter the pattern is. Omnidirectional Antenna Pattern
LXE can supply antennas for practically any environment. Antenna abilities are altered by the RF environment and their placement; such as building construction, building contents and outside RF interference. Factors that impact antenna performance include Tx/Rx frequencies, location of the antenna and cabling.
E-EQ-6200EQRG-B-ARC
6200 Equipment Reference Guide
Page 18
12
Network Management Workstation
Network Management Workstation The network management workstation (NMWS) is the LXE-provided software running in a personal computer (PC) that enables you to enter configuration data or to read diagnostic counters in LXE Network Controllers (NC) or Radio Frequency Units (RFU). Extensive help screens are available on the NMW. The help system is context sensitive -- when help is requested a help screen displays information that directly relates to the data or current screen activity. NMW Main Menu Options File Monitor Configure
New, Open, Save, Save As, Delete, Connect, Quit View Monitor Choices Host Link, Router Table, Network, Terminal, Wireless Modem, Autologin, Console, Passwords, Monitor, Initialize, Upgrade, Resync Time, Exit Diagnose Host Link, RF Link, Connect Header, Text File, Event Log, OS Event Log Help General Help, Edit Help Hot Keys, Current System Previous versions of the NMWS ran on a PC physically connected to the serial port of one of the 6200 units in the system. The NMWS could then “logically” connect to any other unit in the system, but still required a physical connection to the one unit’s COM port. Beginning with version 3.4 of the NMWS, the option of a network connection was added. The PC running the NMWS can connect with any of the 6200 units directly over the network. The serial connection is no longer necessary unless it is a first time connection to a 6200 unit whose NVRAM has been cleared. When the NVRAM has been cleared, the IP address of the 6200 unit is set to 0.0.0.0, making it impossible to reach the 6200 unit by remote means. In previous versions of the NMWS, the serial connection allowed the NMWS to only access the OS of the serially connected unit. Using the network connected version, the NMWS can have a TELNET connection to each unit in the 6200 system. Along with access to the OS on every networked 6200 unit, the latest version of the NMWS also adds a new method to program a 6200 unit’s flash executable code. Previous versions relied on PCMCIA cards used as storage media. The PCMCIA cards were read by the 6200 unit to transfer the flash executable into the 6200 unit’s memory. A new FTP transfer method to reprogram the flash has been added to the latest revision of the software. In the past, flash programming via FTP was complicated, so it was used primarily by LXE developers. Details on the new FTP remote configuration feature is included in “OS Shell Commands”, in the “Network Management Workstation Reference Guide” on the LXE Manuals CD. The NMWS may be started in either the network mode or the serial mode. If the NMWS is started in network mode and the network connection cannot be made, the NMWS reverts to the serial mode. The network version of the NMWS must be run under Windows 95, 98 or NT. On a DOS platform, the NMWS must use the serial mode. The serial mode may also be used under Windows, provided the serial port selected is not being used by another device such as a modem or mouse. Reference Manual : E-SW-6200NMWS[Revision] “6200 Network Management Guide”
6200 Equipment Reference Guide
E-EQ-6200EQRG-B-ARC