Spec sheet · Leuze
Leuze PRK 95/4 Spec Sheet
Spec sheet2 pagesPDF 105 KB
Both pages are below, each with its text.
Covers · 1 model
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A two-page Leuze electronic data sheet for the PRK 95 retro-reflective photoelectric sensor with polarisation filter, ordered as the PRK 95/4 L.2. It gives the features, optical, timing, electrical, mechanical and environmental data, operating ranges with reflectors, a response diagram, accessories and the order guide.
- Device
- Polarised retro-reflective photoelectric sensor using visible red light, with a polarisation filter p. 1
- Supply voltage
- 18 … 30VDC (incl. residual ripple) p. 2
- Output
- 1 PNP transistor output, light switching p. 2
- Range
- Typical operating range limit 0 … 5m with a TK(S) 100x100 reflector p. 2
- Light source
- LED (modulated light), 660nm visible red light, polarised p. 2
- Connection
- M12 connector, stainless steel, 4-pin p. 2
- Housing
- Zinc diecast housing with glass cover p. 1
- Enclosure
- IP 67/IP 69K p. 1
- Indicator
- Yellow switching indicator p. 1
- Optics
- Autocollimation principle, for reliable function over the entire range (0 … max.) p. 1
- Accessories
- Mounting systems (BT 95, UMS 1), M12 connectors (KD …), reflectors, reflective tapes, sold separately p. 1
Good to know
- The IP 69K rating is from a simulated high pressure cleaning test without additives; acids and bases are not part of the test. p. 2
- Its approved purpose is optical, contactless detection of objects. p. 2
Questions this sheet answers
What voltage does the Leuze PRK 95/4 run on?
18 to 30 VDC, including residual ripple. p. 2
What is the range of the PRK 95/4 L.2?
The typical operating range limit is 0 to 5 m with a TK(S) 100x100 reflector. p. 2
What output does the PRK 95/4 have?
One PNP transistor output, light switching. p. 2
What kind of light does the PRK 95 use?
A modulated LED giving polarised visible red light at 660 nm. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
PRK 95
Retro-reflective photoelectric sensors with polarisation filter
Part No. 501 11241Dimensioned drawing0 … 5m 18 - 30 V DC
z Polarised retro-reflective photoelectric sensor using visible red light z The autocollimation principle used ensures that the device functions reliably over the entire range (0 … max.) z Polarisation filter blocks unwanted reflections z Small construction with glass cover and robust zinc diecast housing, protection class IP 67/IP 69K for industrial application z Mounting holes and M12 connector for fast installation
A B
We reserve the right to make changes • 95_b01gb.fm
C
Switching indicator yellow Optical axis
Electrical connectionUL US LISTEDIEC 60947...IEC 60947...IP 69K IP 67
Accessories: (available separately)
z Mounting systems (BT 95, UMS 1) z M12 connectors (KD …) z Reflectors z Reflective tapes
Leuze electronic GmbH + Co. KG info@leuze.de • www.leuze.com
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
PRK 95/4 L.2 - 04
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
PRK 95 SpecificationsTablesOptical dataReflectorsTiming1 2 3 4 5
TK(S) MTK(S) TK(S) TK(S) Tape 2
1 2 3 4 5
0 0 0 0 0
Typ. operating range limit (TK(S) 100x100) 1) 0 … 5m Operating range 2) see tables Light beam characteristic divergent Light source LED (modulated light) Wavelength 660nm (visible red light, polarised) Switching frequency Response time Delay before start-up
200Hz 2.5ms ≤ 100ms
Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics Signal voltage high/low Output current
18 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 30mA 1 PNP transistor output light switching ≥ (UB -2V)/≤ 2V max. 100mA
Indicators LED yellow
Operating range 100x100 0 … 3.4m 50x50 0 … 2.7m 30x50 0 … 1.5m 20x40 0 … 1.4m 100x100 0 … 0.8m 3.4 2.7 2.5 2.4
1.5 1.4 0.85 4.51.2
Operating range [m] Typ. operating range limit [m]
TK … TKS … Tape 2
= adhesive = screw type = adhesive
light path free
Mechanical data diecast zinc glass 90g M12 connector, stainless steel, 4-pin
Environmental data Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class LED class Standards applied
-20°C … 60°C/-30°C … +70°C 2, 3 II, all-insulated IP 67, IP 69K 5) 1 (acc. to EN 60825-1) IEC 60947-5-2
1) Typ. operating range limit: max. attainable range without performance reserve 2) Operating range: recommended range with performance reserve 3) 2=polarity reversal protection, 3=short-circuit protection for all outputs 4) Rating voltage 250VAC 5) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives, acids and bases are not part of the test
Diagrams Typ. response behaviour (TK 100x100) 80
Misalignment y [mm]
Housing Optics cover Weight Connection type
60y240 20 0 -20 -40y1-60
-80 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
Distance x [m]y2 y1 xOrder guidePRK 95/4 L.2 - 04Remarks DesignationPart No.PRK 95/4 L.2500 27993
z Approved purpose: The retro-reflective photoelectric sensors are optical electronic sensors for optical, contactless detection of objects.
0901