The text of a manual · part 80 of 105
Catalog: Optical electronic sensors: Measuring Sensors, pages 773 to 782
Pages 773 to 782 of 1000, from Catalog: Optical electronic sensors
The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3
Page 773
Page 774
Leuze electronic VRTU 430
Ultrasonic distance sensors Dimensioned drawing
60 … 300mm 200 … 1300mm 20 - 30 V DC l Ideal for detection of levels of liquids, bulk materials, transparent media, … l Distance information does not depend on the surface properties l Analogue current output, 1 switching output l All settings are adjustable l Up to 10 devices can be synchronised via the SYNC input l Start and end of switching range adjustable separately
We reserve the right to make changes • USDS_03e.fm
A B C
ISO 9001
IEC 60947...
End of switching range Indicator diode Q1 Start of switching range
Electrical connection IP 65
IEC 60947...
Accessories: (available separately • see page 784)
l Programming software "USDS-Config" l PGU 01 (programming device)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 774 –
VRTU 430M/V-5710-300-S12 - 02 VRTU 430M/V-3710-1300-S12 - 02
Page 775
Page 776
Leuze electronic VRTU 430
Ultrasonic distance sensors Dimensioned drawing
400 … 3000mm 20 - 30 V DC l Ideal for detection of levels of liquids, bulk materials, transparent media, … l Distance information does not depend on the surface properties l All settings are adjustable l Up to 10 devices can be synchronised via the SYNC input l Start and end of switching range adjustable separately
We reserve the right to make changes • USDS_04e.fm
A B C D
ISO 9001
IEC 60947...
End of switching range Indicator diode Q2 ((only for … 430M/P …) Indicator diode Q1 Start of switching range
Electrical connection IP 65
IEC 60947...
Accessories: (available separately • see page 784)
l Programming software "USDS-Config" l PGU 01 (programming device)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 776 –
VRTU 430M/P-2110-3000-S12 - 02
Page 777
Page 778
Leuze electronic VRTU 430
Ultrasonic distance sensors Dimensioned drawing
400 … 3000mm 20 - 30 V DC l Ideal for detection of levels of liquids, bulk materials, transparent media, … l Distance information does not depend on the surface properties l Analogue current output, 1 switching output l All settings are adjustable l Up to 10 devices can be synchronised via the SYNC input l Start and end of switching range adjustable separately
We reserve the right to make changes • USDS_06e.fm
A B C
ISO 9001
IEC 60947...
End of switching range Indicator diode Q1 Start of switching range
Electrical connection IP 65
IEC 60947...
Accessories: (available separately • see page 784)
l Programming software "USDS-Config" l PGU 01 (programming device)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 778 –
VRTU 430M/V-2710-3000-S12 - 02
Page 779
Leuze electronic VRTU 430 Specifications Ultrasonic specifications
Operating range 1) Ultrasonic frequency Opening angle Resolution Absolute measurement accuracy Reproducibility
Tables VRTU…-2710-3000… 400 … 3000mm 120kHz 6° ˜ 1mm ± 1.5% of the measurement range ± 5mm
Timing Switching frequency Response time Delay before start-up Switching hysteresis
2Hz 200ms 280ms 20mm
Electrical data Operating voltage UB Residual ripple Bias current Outputs Function characteristics Output current (PNP/analogue) Analogue output Characteristic curve Switching range adjustment
20 … 30VDC (incl. ± 10% residual ripple) – 10% of UB < 60mA 1 PNP transistor, 1 analogue output switching in case of object recognition 300 mA/4 … 20 mA RL 0 … 300W ascending potentiometer 270°
Indicators LED yellow LED yellow flashing output activated programming error
Diagrams
Mechanical data Housing Weight Connection type metal/CuZn 340g M12 connector, plastic, 5-pin
Environmental data Ambient temp. (operation/storage) Protective circuit 2) VDE safety class 3) Protection class Standards applied Fitting position Explosion protection
-25°C … +70°C/-40°C … +85°C 1, 2, 3 II, all-insulated IP 65 IEC 60947-5-2 any ex zone 2/zone 11/temperature class T5
1) For the complete temperature range, measured object ˜ 50x50mm² 2) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection 3) Rating voltage 250VAC
Remarks
Order guide Designation
Part No.
VRTU 430M/V-2710-3000-S12
500 36268
VRTU 430M/V-2710-3000-S12 - 02 l Synchronisation: mutual interference is excluded by connecting the sensors with the SYNC input. l Multiplex: Achieved by parameterisation of the sensors using the "USDS-Config" software.
0202
– 779 –
Page 780
Leuze electronic VRTU 430
Ultrasonic distance sensors Dimensioned drawing
600 … 6000mm 20 - 30 V DC l Ideal for detection of levels of liquids, bulk materials, transparent media, … l Distance information does not depend on the surface properties l All settings are adjustable l Up to 10 devices can be synchronised via the SYNC input l Start and end of switching range adjustable separately
We reserve the right to make changes • USDS_08e.fm
A B C D
ISO 9001
IEC 60947...
End of switching range Indicator diode Q2 only for … 430M/P … Indicator diode Q1 Start of switching range
Electrical connection IP 65
IEC 60947...
Accessories: (available separately • see page 784)
l Programming software "USDS-Config" l PGU 01 (programming device)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 780 –
VRTU 430M/P-1110-6000-S12 - 02
Page 781
Page 782
Leuze electronic VRTU 430
Ultrasonic distance sensors Dimensioned drawing
600 … 6000mm 20 - 30 V DC l Ideal for detection of levels of liquids, bulk materials, transparent media, … l Distance information does not depend on the surface properties l Analogue current output, 1 switching output l All settings are adjustable l Up to 10 devices can be synchronised via the SYNC input l Start and end of switching range adjustable separately
We reserve the right to make changes • USDS_07e.fm
A B C
ISO 9001
IEC 60947...
End of switching range Indicator diode Q1 Start of switching range
Electrical connection IP 65
IEC 60947...
Accessories: (available separately • see page 784)
l Programming software "USDS-Config" l PGU 01 ((programming device)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 782 –
VRTU 430M/V-1710-6000-S12 - 02