The text of a manual · part 79 of 105
Catalog: Optical electronic sensors: Measuring Sensors, pages 763 to 772
Pages 763 to 772 of 1000, from Catalog: Optical electronic sensors
The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3
Page 763
Leuze electronic
Optical Sensor ABCs
Cubic Series
Cylindrical Series – Mini photoelectric sensors – Fibre optic devices
Forked Photoelectric Sensors
Measuring Sensors
Contrast Scanners – Colour Sensors – Luminescence Scanners
Explosion Protection
Protective Photoelectric Sensors – Type 2
Accessories
Further Product Range
Appendix – Index
– 763 –
Page 764
Leuze electronic
– 764 –
Page 765
Leuze electronic
USDS - Ultrasonic distance sensors Overview and advantages - Distance measurement using the ultrasonic principle - Measurement ranges from 50mm to 6000mm
Distance information nearly independent of surface properties
Outputs: - 2 switching outputs - Analogue current output
Operating principles: - HRTU models with background suppression - VRTU models with foreground suppression and background suppression
HRTU 418M/V… and VRTU 430M/V… models can be configured via PC-software and programming terminal
M18 or M30 housings
– 765 –
Page 766
Leuze electronic Sensor selection table
50 … 300mm
HRTU 418M/P-3010-1000-S12
150 … 1000mm
HRTU 418M/V-5010-300-S12
50 … 300mm
HRTU 418M/V-3010-1000-S12
150 … 1000mm
VRTU 430M/P-5110-300-S12
60 … 300mm
VRTU 430M/P-3110-1300-S12
200 … 1300mm
VRTU 430M/V-5710-300-S12
60 … 300mm
VRTU 430M/V-3710-1300-S12
200 … 1300mm
VRTU 430M/P-2110-3000-S12
400 … 3000mm
VRTU 430M/V-2710-3000-S12
400 … 3000mm
VRTU 430M/P-1110-6000-S12
600 … 6000mm
VRTU 430M/V-1710-6000-S12
600 … 6000mm
• • • •
• • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
– 766 –
Output
• • • • • • • • • • • •
• • • • • • • •
NPN transistor
• • • •
Switching
PNP transistor
Operating voltage
2nd switching output
Measurement principle
Analogue output 4 … 20mA
Housing
20 … 30VDC
HRTU 418M/P-5010-300-S12
Operating range
Ultrasonics
Designation
Metal
Operating principle
Page 767
Leuze electronic
4Hz
4Hz 8Hz 4Hz 2Hz 2Hz 1Hz 1Hz
• • • •
• • • • • • • •
• • • • • • • •
• • • • • • • •
– 767 –
Foreground suppression
• • • •
• • • • • • • •
Transparent media
8Hz
5Hz
• • • •
Page
Operating range adjustment
• • • • • • • •
4Hz
Background suppression
5Hz
Synchronisation input
• • • •
Parameterisation possible
Options
Teachable switching outputs
Switching frequency
M12 connector
Cable
Connection
• • • •
• • • •
769 769 771 771
• • • • • • • •
• • • • • • • •
773 773 775 775 777 779 781 783
Page 768
Specifications and description
Leuze electronic
HRTU 418
Ultrasonic distance sensors Dimensioned drawing
50 … 300mm 150 … 1000mm 20 - 30 V DC l Ideal for detection of levels of liquids, bulk materials, transparent media, … l Distance information does not depend on the surface properties l All settings are adjustable l Up to 10 devices can be synchronised via the SYNC input l Start and end of switching range adjustable separately
We reserve the right to make changes • USDS_01e.fm
A B
ISO 9001
IEC 60947...
End of switching range (only for … 418M/P …) Indicator diodes Q1
Electrical connection IP 67
IEC 60947...
Accessories: (available separately • see page 784)
l Programming software "USDS-Config" l PGU 01 (programming device)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 768 –
HRTU 418M/P-5010-300-S12 - 02 HRTU 418M/P-3010-1000-S12 - 02
Page 769
Page 770
Leuze electronic HRTU 418
Ultrasonic distance sensors Dimensioned drawing
50 … 300mm 150 … 1000mm 20 - 30 V DC l Ideal for detection of levels of liquids, bulk materials, transparent media, … l Distance information does not depend on the surface properties l All settings are adjustable l Up to 10 devices can be synchronised via the SYNC input l Start and end of switching range adjustable separately
We reserve the right to make changes • USDS_02e.fm
A
ISO 9001
IEC 60947...
Indicator diodes Q1
Electrical connection IP 67
IEC 60947...
Accessories: (available separately • see page 784)
l Programming software "USDS-Config" l PGU 01 (programming device)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 770 –
HRTU 418M/V-5010-300-S12 - 02 HRTU 418M/V-3010-1000-S12 - 02
Page 771
Page 772
Leuze electronic VRTU 430
Ultrasonic distance sensors Dimensioned drawing
60 … 300mm 200 … 1300mm 20 - 30 V DC l Ideal for detection of levels of liquids, bulk materials, transparent media, … l Distance information does not depend on the surface properties l All settings are adjustable l Up to 10 devices can be synchronised via the SYNC input l Start and end of switching range adjustable separately
We reserve the right to make changes • USDS_05e.fm
A B C D
ISO 9001
IEC 60947...
End of switching range Indicator diode Q2 only for … 430M/P … Indicator diode Q1 Start of switching range
Electrical connection IP 65
IEC 60947...
Accessories: (available separately • see page 784)
l Programming software "USDS-Config" l PGU 01 (programming device)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 772 –
VRTU 430M/P-5110-300-S12 - 02 VRTU 430M/P-3110-1300-S12 - 02