Page 8
Leuze electronic
Safety Notices
2
Safety Notices
2.1
Safety Standard
The bar code reader BCL 80 and the connector unit MA 10 have been developed, produced and tested subject to the applicable safety standards. They correspond to the state of the art.
2.2
Intended Use Attention! The protection of personnel and the device cannot be guaranteed if the device is operated in a manner not corresponding to its intended use.
Bar code readers of the type BCL 80 are conceived as stationary, high-speed scanners with integrated decoders for all current bar codes used for automatic object recognition. The connector and interface unit MA 10 simplifies the connection of the bar code reader of type BCL 80 / BCL 40 and adapts to various host interfaces. Connection to other bar code readers is not authorised. In particular, unauthorised use includes: • rooms with explosive atmospheres • operation for medical purposes
Fields of application The bar code reader BCL 80 with optional connector unit MA 10 is conceived particularly for the following fields of application: • for package distribution and sorting installations • for pallet transportation applications • storage and conveying engineering, in particular for object identification on fast-moving conveyor belts • pharmaceutical industry • for all applications where great depth of focus and reading distances are required
2.3
Working Safety Attention Laser Radiation! The BCL 80 is a laser device of laser class 2. Do not look directly into the laser beam. Observe the legal and local regulations applicable to the operation of laser units.
• Never look at the laser beam directly (same as sunlight). • Do not point the laser beam of the device to other persons. • When mounting and adjusting the BCL, heed the reflection of the laser beam on reflective surfaces. • Do not open the housing. Opening it does not interrupt the activation of the laser diode through read clocking. • Heed the laser safety regulations according to DIN EN 60825-1 (most current version).
6
Technical Description BCL 80
Leuze electronic
Page 9
Leuze electronic 2.4
Safety Notices
Organisational Measures
Documentation All entries in this operating manual must be heeded, in particular those in the sections "Safety Notices" and "Commissioning". Carefully store this operating manual where it is accessible at all times.
Safety regulations Observe the locally applicable legal regulations and the rules of the employers’ liability insurance association.
Qualified personnel Mounting, commissioning and maintenance of the device may only be carried out by qualified personnel. Electrical work must be carried out by a certified electrician.
Repair
TNT 35/7-24V
Repairs must only be carried out by the manufacturer or an authorised representative.
Leuze electronic
Technical Description BCL 80
7
Page 10
Leuze electronic
Description
3
Description
3.1
The Bar Code Readers BCL 80
The bar code reader BCL 80 is a high-speed scanner with integrated decoder for all bar codes currently in use, e.g. 2/5 Interleaved, EAN, etc. The many possible configurations of the device allow its adaptation to a multitude of reading tasks. Due to the large reading distance combined with the great depth of focus, the device is ideally suited for package and pallet transportation systems. Together with the connector unit MA 10, it can easily be adapted for use with various interfaces, thus allowing additional processing by other systems. The MA 10 connector unit can also be used to network together several BCL 80 devices and to simplify electrical installation.
3.2
Features of the BCL 80
Performance features • • • • • • • • • • • •
Maximum depth of focus Scanning rate: 600 Scans/s; application-specific adjustable Maximum reading distance of 2300 mm A switched input for triggering a read process using sensors Automatic monitoring of the read quality with the 'autoControl' function Automatic recognition of the bar code type using 'autoConfig' All device parameters can be set by software Heavy-duty housing of protection class IP 65 with corresponding cable RS 232 or RS 485 interface to host Extensive formatting possibilities for data output Reference code (comparison code) A version of the BCL 80 with an oscillating mirror add-on is available
Added features with MA 10 • Device status display with 4 LEDs • RS 485 interface with electrical isolation for networking several devices • Alternative interface RS 232, RS 422 or TTY using a selectable interface module with electrical isolation for directly connecting to the host • Switched output for status messages (second output on request) • Additional switched input for the definition of reference code 1 • Simple electrical connection via double terminal clamps, i.e. both the power supply and the interface circuits can easily be connected in series. • Heavy-duty housing of protection class IP 65 • 2 parameter sets can be stored locally in the MA 10 (current parameter set, customer-specific parameter set) • Built-in RS 232 service interface for fast commissioning or troubleshooting on site using a PC or programming device • Switch for the autoConfig function
8
Technical Description BCL 80
Leuze electronic
Page 11
Leuze electronic
Description
Modular Concept BCL 80 ’stand alone’
€
The bar code reader BCL 80 can be operated as an individual ’stand alone’ ( ) device. Electrical connection of the power supply, interface and switched input are centrally made via a 15 pin SubD socket. For connection, it is best to use the 15 conductor connection cable from Leuze. The requirements for protection class IP 65 are fulfilled when using this cable only (see Chapter 5)!
BCL 80 with MA 10 When using several BCL 80 units or under rough environment conditions, the installation of one connector unit MA 10 for each BCL 80 unit is recommended. Electrical connection, commissioning, and service can be comfortably carried out in a short period of time.
ó
The BCL 80 and MA 10 can be mounted directly together ( ) or arranged separately next to each other. When mounted separately ( ), the two units are connected by a cable. Protection class IP 65 is maintained when the sealed accessory cable is used (see Chapter 5).
ì
€
BCL 80 as ’Stand alone’-device
ó
TNT 35/7-24V
BCL 80 with the connector unit MA 10 mounted together
ì
BCL 80 and MA 10 mounted separately and connected together by a cable
Figure 3.1:
Possible combinations of the BCL 80 / MA 10
Leuze electronic
Technical Description BCL 80
9
Page 12
Leuze electronic
Description Networking
Up to 31 BCL 80 bar code readers can be networked together using the connector unit MA 10 (with interface module RS 485). The devices are interconnected by connecting the individual RS 485 interfaces in parallel.
multiNet plus In the Leuze multiNet plus, the individual network devices sequentially transfer their data to the network master MA 30 when requested (’polling’). The master station can also be fitted with an BCL 80, making it a complete scanner station which also controls the network. Each network device declared as a slave maintains a device address which is set in the respective MA 10 with a coding switch. If the reader unit is exchanged (BCL), the device address and all settings in the MA 10 are maintained. The master then transmits the data of all network devices via its host interface to a primary PLC control system or a computer, i.e. it ’collects’ the scanner data in the network and transmits them to one interface on the host computer. This reduces interface costs (CP’s) and time programming the software. Suitable network master devices are: DD 55, MDS 70 and MA 30.
Sensor
Sensor optional • RS 485, • RS 232, • RS 422 or • TTY Network-Master multiNet plus MA 30
- Backup - Parameter
RS 485
Sensor
Figure 3.2:
10
Voltage supply
Networking possibilities using the multiNet plus
Technical Description BCL 80
Leuze electronic
Page 13
Leuze electronic
Description
Two-wire RS 485 The Leuze MultiNet plus is optimised for fast transmission of scanner data to a primary host computer. The multiNet plus physically consists of a two-wire RS 485 interface through which the multiNet plus software protocol is controlled. This makes wiring the network easy and inexpensive since slaves are connected to each another in parallel.
Interface modules Shielded, twisted pair conductors should be used for the multiNet. This allows a total network length of up to 1200 m. Connection of the network to the primary computer is made via the host interface of the MA 30 which can be equipped with 4 different physical interface modules. Modules for RS 232, RS 422, TTY and RS 485 are available.
3.3
Construction
Device construction BCL 80 4 fastening threads M4 on the rear of the device
TNT 35/7-24V
’Ready’ LED on the rear of the device
Reading window Figure 3.3:
Dovetail fastening groove
15 pin SubD connector
Bar code reader BCL 80
Leuze electronic
Technical Description BCL 80
11
Page 14
Leuze electronic
Description Device construction MA 10 Mounting holes for the BCL 80 with M4 screws
4 Status-LEDs on the rear
Screw gland PG11 for the power supply cable
Screw glands PG9 for the switched input and the interface cables
15-pin SubD connector
4 fastening threads M4 on the base of the device
Dovetail fastening grooves Fig. 3.4: connector unit MA 10
Device variations MA 10 The MA 10 is available in four models: • • • •
MA 10 100 with host interface module RS 485 MA 10 110 with host interface module RS 232 MA 10 120 with host interface module TTY MA 10 130 with host interface module RS 422
All modules are galvanically isolated, i.e. they are EMC interference protected and immune to differences in voltage potentials across long cable lengths.
Note! Only the type MA 10 100 can be used as a multiNet slave unit.
12
Technical Description BCL 80
Leuze electronic