For the Leuze MA 10
Page 70
Leuze electronic
Configuration Parameter
Valid range of values
Label Footer 1
Nothing Tag Header Char 1 No. of Label Codetype Digits Label Quality
Label Footer 2
Nothing Tag Header Char 1 No. of Label Codetype Digits Label Quality
Label Footer 3
Nothing Tag Header Char 1 No. of Label Codetype Digits Label Quality Other entries on request
Output constants Characters and texts can be entered from the menu’ Output Constants’ for the following format characters: • • • • •
Title header character Label header text character 1 Label separation character Good read character No read string
Parameter Prefix Character Label Header Text Character 1 Label Separator Character Good Read Char Text for unsuccessful scan
Valid range of values ASCII character ASCII character ASCII character ASCII character text string with up to 20 characters
Default [00H] [00H] [20H] [00H] [18H]
Note! The characters can be entered as decimal code, hexadecimal code or as a character. Characters set to ’00H’ are not output!
68
Technical Description BCL 80
Leuze electronic
Page 71
Leuze electronic
Configuration
9.2.4 Setting the Host Interface Parameters The following submenus can be selected in the menu ’Host Interface’ of the Setup program: • General Settings • Framing Protocol • 3964 / RK 512 Protocol
General Settings In the menu 'General Settings', the parameters are entered for the serial transfer to the host: Data format Baud rate Protocol Handshake Mode
Parameter
Valid range of values
Data Format
7 Bit, no parity, 7 Bit, even parity, 7 Bit, even parity, 7 Bit, odd parity, 7 Bit, odd parity, 8 Bit, no parity, 8 Bit, no parity, 8 Bit, even parity, 8 Bit, even parity, 8 Bit, odd parity, 8 Bit, odd parity, 9 Bit, no parity, multiNet mode
Baudrate
110 300 600 1200 2400 4800 9600 19200 38400 57600
Leuze electronic
Technical Description BCL 80
2 stop bits 1 stop bit 2 stop bits 1 stop bit 2 stop bits 1 stop bit 2 stop bits 1 stop bit 2 stop bits 1 stop bit 2 stop bits 1 stop bit
TNT 35/7-24V
• • • • baud baud baud baud baud baud baud baud baud baud
69
Page 72
Leuze electronic
Configuration Parameter
Valid range of values
Protocol
No protocol Protocol Frame Protocol frame with acknowledge 3964 / RK 512 Protocol multiNet Plus slave
Handshake Mode
No Handshake RTS RTS / CTS RTS / CTS ; TX active Half duplex XON / XOFF
Framing Protocol The following parameters for transfer to the host can be set in the menu ’Framing Protocol’: • • • • • •
Prefix 1 (title header character) Prefix 2 (title header character) Postfix 1 (title footer character) Postfix 2 (title footer character) Address Format BCC Mode (Block Check Character)
Parameter
Valid range of values
Default
Prefix 1 Prefix 2 Postfix 1 Postfix 2
00h … FFh 00h … FFh 00h … FFh 00h … FFh
[02h] [00h] [0Dh] [0Ah]
Address Format
No Address Binary address ASCII address
BCC-Mode
No BCC BCC mode 1 BCC mode 2 BCC mode 3
More detailed information concerning the BCC modes is available on request.
Note! If the BCL 80 should operate ’stand alone’ as a slave in the multiNet, then the following settings are required: Data format: multiNet mode Baud rate: 57600 baud Protocol: MultiNet Plus slave Handshake: none Address format: ASCII address
70
Technical Description BCL 80
Leuze electronic
Page 73
Leuze electronic
Configuration
3964 / RK 512 Protocol The BCL 80 / MA 10 can be operated with the procedure 3964 / RK 512. For this the option ’3964 / RK 512 protocol’ must be activated in the menu ’General Settings / Protocol’. The required parameters are set in the menu ’3964 / RK 512’. The following operating modes are possible: • 3964 • 3964 R • 3964 / RK 512 Parameter
Valid range of values
Default use BCC within 3964 transmit with high priority character receive timeout acknowledge receive timeout no. of retransmissions use RK 512 no. of data module start address within module address offset of slave use reaction telegr. in RK 512
Yes, No Yes, No 0 … 3000 ms 0 … 3000 ms 0 … 255 Yes, No 0 … 255 0 … 255 0 … 255 Yes, No
[No] [No] [220] [550] [5] [No] [10] [0] [64] [No]
9.2.5 Setting the Parameters of the Digital IN/OUT The following submenus can be selected from the menu 'Digital IN/OUT': Sensor Decode (S1) Sensor Teach In (S2) Switch 1 Switch 2
TNT 35/7-24V
• • • •
Sensor Decode (S1) The switching parameters of this input can be entered in the menu 'Sensor Decode (S1)': • Debounce Time • Delay Off • Inversion Parameter
Valid range of values
Default
Debounce Time Delay Off Inversion
0 … 255 ms 0 … 2500 ms Yes, No
[5] [0] [No]
Leuze electronic
Technical Description BCL 80
71
Page 74
Leuze electronic
Configuration Sensor Teach In (S2)
The switching parameters of this input can be entered in the menu ’Sensor Teach-In (S2)’: • Debounce Time • Delay Off • Inversion Parameter
Valid range of values
Default
Debounce time Delay Off Inversion
0 … 255 ms 0 … 2500 ms Yes, No
[5] [0] [No]
Note! When using switches with contact bounce (e.g. relay contacts) set the end bounce time high (between 50 and 255 ms), since contact bounce can cause multiple switching impulses and interfere with the BCL software.
Switch 1 The switching parameters of this output can be entered in the menu 'Switch 1': • Enable • Activation • Inversion Parameter
Valid range of values
Default
Enable
Yes, No
[Yes]
Activation
Good Read Bad Read Start Reading Stop Reading Device Ready autoControl Reference code 1 Reference code 2
Inversion
Yes, No
72
Technical Description BCL 80
[No]
Leuze electronic
Page 75
Leuze electronic
Configuration
Switch 2 The switching parameters of this output can be entered in the menu ’Switch 2’: • Enable • Activation • Inversion Parameter
Valid range of values
Default
Enable
Yes, No
[No]
Activation
Good Read Bad Read Start Reading Stop Reading Device Ready autoControl Reference code 1 Reference code 2
Inversion
Yes, No
[No]
9.2.6 Setting the General Parameters Generals
• Decoder address: A decoder address must be set if the BCL 80 is to be operated without an MA 10 in the multiNet, thus no address switch is available. Here the option 'Host interface / frame protocol / ASCII address' must be activated. The hardware switch has priority when operating with an MA 10. • Startcode character • Error character • Warning character Parameter
Valid range of values
Default
Decoder address Startcode character Error character Warning character
00h … 1Fh 00h … 7Ah 00h … 7Ah 00h … 7Ah
[00h] ['S'] ['&'] ['@']
Leuze electronic
Technical Description BCL 80
73
TNT 35/7-24V
The following parameters can be set in the menu 'Generals' of the setup program:
Page 76
Leuze electronic
Configuration
9.2.7 Additional Functions: Setting the Reference Code Parameters The following submenus can be selected from the submenu ’Reference Code’ under the menu ’Additional Functions’: • Code 1 • Code 2 • Don't care i.e. two reference codes can be defined and particular characters hidden.
Code 1 and Code 2 The following can be defined for code 1 and code 2: • The content of the label to be read • The code type of the label to be read • Comparison operations which activate switch 1 or 2 Parameter Code information
Valid range of values contents of the label to be detected
Default [' ']
Code type selection code types that can also be set as decoding parameters
['none']
Compare Mode
No compare Equal Unequal
Settings for 'Comparison mode' no comparison: deactivates the reference code detection, equal:
activates the set switching output when detected code and reference code are equal, unequal:
activates the set switching output when detected code and reference code are not equal
The assignment of switching output 1/2 to reference code 1/2 is set in the menu 'Switching inputs/outputs / Switching output 1/2 / Activation'.
Don’t care In order to allow the comparison of several similar labels, a 'Don't Care' character can be defined. The character is not permanently defined, thus giving the user the greatest flexibility when defining the reference code. It should be defined so that it does not occur in the code which will be read. Parameter Definition Mode Don't Care Character
Valid range of values Yes, No any ASCII character
Default [No] ['*']
Settings for 'Override mode' Yes: When a reference code is defined, the 'Don't care' character is taken into account No: When a reference code is defined, the 'Don't care' character is not taken into account Example: Code 1: Code Info: 1234**** By setting the 'Don't-Care' character, the affected positions are "ignored", i.e. they are not relevant to the code comparison.
74
Technical Description BCL 80
Leuze electronic
Page 77
Leuze electronic
Configuration
9.2.8 Additional Functions: Setting the ’autoControl’ Parameters The following submenus can be selected from the submenu ’autoControl’ under the menu ’Additional Functions’: • • • •
Enable Limit Scan Quality Send Warning to Com Character for AutoControl warning
Enable Specify here whether the autoControl function is activated. Parameter Enable
Valid range of values Yes, No
Default [No]
Limit Scan Quality The scan quality is defined as the relationship between the number of decodable scans to the total number of possible scans. A threshold in percent can be entered here. If the percent of successful scans falls below this limit, a warning message will be sent and, if enabled, a switched output can be activated. Parameter Limit Scan Quality
Valid range of values 0 … 100 in %
Default [50]
Specify here whether a warning message should be output over the serial interface if the scan quality falls below the given value. Parameter Send warning to com
Valid range of values Yes, No
Default [No]
Character for AutoControl warning Define here the warning character which will be sent out over the serial interface if the scan quality falls below the given limit. It can be any ASCII character. Parameter Valid range of values Character for AutoControl warning all ASCII characters
Default ['!']
00: no output via the serial interface
Leuze electronic
Technical Description BCL 80
75
TNT 35/7-24V
Send Warning to Com