For the Leuze MA 10

Page 70

Leuze electronic

Configuration Parameter

Valid range of values

Label Footer 1

Nothing Tag Header Char 1 No. of Label Codetype Digits Label Quality

Label Footer 2

Nothing Tag Header Char 1 No. of Label Codetype Digits Label Quality

Label Footer 3

Nothing Tag Header Char 1 No. of Label Codetype Digits Label Quality Other entries on request

Output constants Characters and texts can be entered from the menu’ Output Constants’ for the following format characters: • • • • •

Title header character Label header text character 1 Label separation character Good read character No read string

Parameter Prefix Character Label Header Text Character 1 Label Separator Character Good Read Char Text for unsuccessful scan

Valid range of values ASCII character ASCII character ASCII character ASCII character text string with up to 20 characters

Default [00H] [00H] [20H] [00H] [18H]

Note! The characters can be entered as decimal code, hexadecimal code or as a character. Characters set to ’00H’ are not output!

68

Technical Description BCL 80

Leuze electronic

Page 71

Leuze electronic

Configuration

9.2.4 Setting the Host Interface Parameters The following submenus can be selected in the menu ’Host Interface’ of the Setup program: • General Settings • Framing Protocol • 3964 / RK 512 Protocol

General Settings In the menu 'General Settings', the parameters are entered for the serial transfer to the host: Data format Baud rate Protocol Handshake Mode

Parameter

Valid range of values

Data Format

7 Bit, no parity, 7 Bit, even parity, 7 Bit, even parity, 7 Bit, odd parity, 7 Bit, odd parity, 8 Bit, no parity, 8 Bit, no parity, 8 Bit, even parity, 8 Bit, even parity, 8 Bit, odd parity, 8 Bit, odd parity, 9 Bit, no parity, multiNet mode

Baudrate

110 300 600 1200 2400 4800 9600 19200 38400 57600

Leuze electronic

Technical Description BCL 80

2 stop bits 1 stop bit 2 stop bits 1 stop bit 2 stop bits 1 stop bit 2 stop bits 1 stop bit 2 stop bits 1 stop bit 2 stop bits 1 stop bit

TNT 35/7-24V

• • • • baud baud baud baud baud baud baud baud baud baud

69

Page 72

Leuze electronic

Configuration Parameter

Valid range of values

Protocol

No protocol Protocol Frame Protocol frame with acknowledge 3964 / RK 512 Protocol multiNet Plus slave

Handshake Mode

No Handshake RTS RTS / CTS RTS / CTS ; TX active Half duplex XON / XOFF

Framing Protocol The following parameters for transfer to the host can be set in the menu ’Framing Protocol’: • • • • • •

Prefix 1 (title header character) Prefix 2 (title header character) Postfix 1 (title footer character) Postfix 2 (title footer character) Address Format BCC Mode (Block Check Character)

Parameter

Valid range of values

Default

Prefix 1 Prefix 2 Postfix 1 Postfix 2

00h … FFh 00h … FFh 00h … FFh 00h … FFh

[02h] [00h] [0Dh] [0Ah]

Address Format

No Address Binary address ASCII address

BCC-Mode

No BCC BCC mode 1 BCC mode 2 BCC mode 3

More detailed information concerning the BCC modes is available on request.

Note! If the BCL 80 should operate ’stand alone’ as a slave in the multiNet, then the following settings are required: Data format: multiNet mode Baud rate: 57600 baud Protocol: MultiNet Plus slave Handshake: none Address format: ASCII address

70

Technical Description BCL 80

Leuze electronic

Page 73

Leuze electronic

Configuration

3964 / RK 512 Protocol The BCL 80 / MA 10 can be operated with the procedure 3964 / RK 512. For this the option ’3964 / RK 512 protocol’ must be activated in the menu ’General Settings / Protocol’. The required parameters are set in the menu ’3964 / RK 512’. The following operating modes are possible: • 3964 • 3964 R • 3964 / RK 512 Parameter

Valid range of values

Default use BCC within 3964 transmit with high priority character receive timeout acknowledge receive timeout no. of retransmissions use RK 512 no. of data module start address within module address offset of slave use reaction telegr. in RK 512

Yes, No Yes, No 0 … 3000 ms 0 … 3000 ms 0 … 255 Yes, No 0 … 255 0 … 255 0 … 255 Yes, No

[No] [No] [220] [550] [5] [No] [10] [0] [64] [No]

9.2.5 Setting the Parameters of the Digital IN/OUT The following submenus can be selected from the menu 'Digital IN/OUT': Sensor Decode (S1) Sensor Teach In (S2) Switch 1 Switch 2

TNT 35/7-24V

• • • •

Sensor Decode (S1) The switching parameters of this input can be entered in the menu 'Sensor Decode (S1)': • Debounce Time • Delay Off • Inversion Parameter

Valid range of values

Default

Debounce Time Delay Off Inversion

0 … 255 ms 0 … 2500 ms Yes, No

[5] [0] [No]

Leuze electronic

Technical Description BCL 80

71

Page 74

Leuze electronic

Configuration Sensor Teach In (S2)

The switching parameters of this input can be entered in the menu ’Sensor Teach-In (S2)’: • Debounce Time • Delay Off • Inversion Parameter

Valid range of values

Default

Debounce time Delay Off Inversion

0 … 255 ms 0 … 2500 ms Yes, No

[5] [0] [No]

Note! When using switches with contact bounce (e.g. relay contacts) set the end bounce time high (between 50 and 255 ms), since contact bounce can cause multiple switching impulses and interfere with the BCL software.

Switch 1 The switching parameters of this output can be entered in the menu 'Switch 1': • Enable • Activation • Inversion Parameter

Valid range of values

Default

Enable

Yes, No

[Yes]

Activation

Good Read Bad Read Start Reading Stop Reading Device Ready autoControl Reference code 1 Reference code 2

Inversion

Yes, No

72

Technical Description BCL 80

[No]

Leuze electronic

Page 75

Leuze electronic

Configuration

Switch 2 The switching parameters of this output can be entered in the menu ’Switch 2’: • Enable • Activation • Inversion Parameter

Valid range of values

Default

Enable

Yes, No

[No]

Activation

Good Read Bad Read Start Reading Stop Reading Device Ready autoControl Reference code 1 Reference code 2

Inversion

Yes, No

[No]

9.2.6 Setting the General Parameters Generals

• Decoder address: A decoder address must be set if the BCL 80 is to be operated without an MA 10 in the multiNet, thus no address switch is available. Here the option 'Host interface / frame protocol / ASCII address' must be activated. The hardware switch has priority when operating with an MA 10. • Startcode character • Error character • Warning character Parameter

Valid range of values

Default

Decoder address Startcode character Error character Warning character

00h … 1Fh 00h … 7Ah 00h … 7Ah 00h … 7Ah

[00h] ['S'] ['&'] ['@']

Leuze electronic

Technical Description BCL 80

73

TNT 35/7-24V

The following parameters can be set in the menu 'Generals' of the setup program:

Page 76

Leuze electronic

Configuration

9.2.7 Additional Functions: Setting the Reference Code Parameters The following submenus can be selected from the submenu ’Reference Code’ under the menu ’Additional Functions’: • Code 1 • Code 2 • Don't care i.e. two reference codes can be defined and particular characters hidden.

Code 1 and Code 2 The following can be defined for code 1 and code 2: • The content of the label to be read • The code type of the label to be read • Comparison operations which activate switch 1 or 2 Parameter Code information

Valid range of values contents of the label to be detected

Default [' ']

Code type selection code types that can also be set as decoding parameters

['none']

Compare Mode

No compare Equal Unequal

Settings for 'Comparison mode' no comparison: deactivates the reference code detection, equal:

activates the set switching output when detected code and reference code are equal, unequal:

activates the set switching output when detected code and reference code are not equal

The assignment of switching output 1/2 to reference code 1/2 is set in the menu 'Switching inputs/outputs / Switching output 1/2 / Activation'.

Don’t care In order to allow the comparison of several similar labels, a 'Don't Care' character can be defined. The character is not permanently defined, thus giving the user the greatest flexibility when defining the reference code. It should be defined so that it does not occur in the code which will be read. Parameter Definition Mode Don't Care Character

Valid range of values Yes, No any ASCII character

Default [No] ['*']

Settings for 'Override mode' Yes: When a reference code is defined, the 'Don't care' character is taken into account No: When a reference code is defined, the 'Don't care' character is not taken into account Example: Code 1: Code Info: 1234**** By setting the 'Don't-Care' character, the affected positions are "ignored", i.e. they are not relevant to the code comparison.

74

Technical Description BCL 80

Leuze electronic

Page 77

Leuze electronic

Configuration

9.2.8 Additional Functions: Setting the ’autoControl’ Parameters The following submenus can be selected from the submenu ’autoControl’ under the menu ’Additional Functions’: • • • •

Enable Limit Scan Quality Send Warning to Com Character for AutoControl warning

Enable Specify here whether the autoControl function is activated. Parameter Enable

Valid range of values Yes, No

Default [No]

Limit Scan Quality The scan quality is defined as the relationship between the number of decodable scans to the total number of possible scans. A threshold in percent can be entered here. If the percent of successful scans falls below this limit, a warning message will be sent and, if enabled, a switched output can be activated. Parameter Limit Scan Quality

Valid range of values 0 … 100 in %

Default [50]

Specify here whether a warning message should be output over the serial interface if the scan quality falls below the given value. Parameter Send warning to com

Valid range of values Yes, No

Default [No]

Character for AutoControl warning Define here the warning character which will be sent out over the serial interface if the scan quality falls below the given limit. It can be any ASCII character. Parameter Valid range of values Character for AutoControl warning all ASCII characters

Default ['!']

00: no output via the serial interface

Leuze electronic

Technical Description BCL 80

75

TNT 35/7-24V

Send Warning to Com