Leuze electronic technical description for the BCL 45 bar code scanner for DeviceNet and its MA 15 connector unit. It gives features, specifications, the connector unit's switches and terminals, the LED status meanings, network addressing and the order list of scanner versions.

Type
High-speed bar code scanner with integrated CAN bus interface, run on the Device-Net protocol p. 2
Operating voltage
11 ... 30 V DC p. 1, 2
Scanning rate
1200 scans/s, with automatic code type detection p. 1
Codes read
All standard bar codes, e.g. 2/5 Interleave and Code 39 p. 2
Service interface
RS 232 on a 9-pole SubD plug (2=RxD, 3=TxD, 5=GND), for setup and data monitoring p. 1, 3
Housing
Diecast aluminum, IP 65 p. 2
Baud rate
Set by rotary switch: 0 = 125 kb, 1 = 250 kb, 2 = 500 kb; above 2, set by software p. 3
Node address
Two rotary switches: tens 0 to 6, units 0 to 9; addresses above 63 set by software p. 4
Network size
15 to 63 bar code readers can be linked in one Device-Net network p. 2
Sensor input
12 ... 36 V DC/AC on terminals 7, 9, 11 and 12, to trigger the scanner p. 3
Switching output
5 ... 48 V DC on terminals 13 to 16, e.g. for good read or bad read p. 3
Versions
Raster scanners with F, N or M optics; single-beam scanners with F or M optics p. 4
Connector unit
MA 15 150, connector unit for the Device-Net slave BCL 45 p. 4
Environment
Storage -20°C ... +60°C; max. 90% relative humidity, non-condensing p. 2

What this sheet walks you through

  • Outline dimensions of the BCL 45 with the MA 15 p. 1
  • Device-Net messages used to exchange data with the PLC master p. 2
  • MA 15 switches, plugs and terminals p. 3
  • Switching to service mode with DIP switch 3 p. 3
  • Setting the baud rate and Device-Net address p. 3, 4
  • Reading the LED status indicators p. 4
  • Ordering scanner versions and the connector unit p. 4

Good to know

  • Addresses above 63 are set by software rather than the rotary switches. p. 4
  • A flashing red MNS LED means the message connection timed out; it clears when the connection is reestablished. p. 4

Questions this sheet answers

What does a steady red MNS LED mean on the Leuze BCL 45?

A serious error such as a buffer overflow; switch the unit off and on or reset the BCL 45. p. 4

How do I set the Device-Net address of a BCL 45?

Use the two rotary switches in the MA 15: the MSD switch sets the tens digit and the LSD switch the units; for address 32 set 3 and 2. p. 4

What baud rates does the BCL 45 support on Device-Net?

125 kb, 250 kb or 500 kb, chosen with the rotary switch (positions 0, 1, 2); higher positions leave it to software. p. 3

What voltage does the BCL 45 need?

11 to 30 V DC. p. 1, 2

The file

Size and text

Pages4
PDF375 KB
TextText from the PDF itself.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Leuze BCL-45 Spec Sheet

The text of page 1, from the PDF itself

Leuze electronic Dimensioned drawing

BCL 45 / MA 15

Bar Code Scanner for Device-Net with Connector Unit 11 - 30 V DC

AODVAFeatures

We reserve the right to make changes

l Scanning rate 1200 scans/s l Automatic code type detection Automatic code quality check l Additional RS232 service interface l Scanner parameterization via Device-Net or service interface l MAC ID and baud rate set via rotary code switch l Device status visualization l Parameters are stored fail-safe in an EEPROM l Switching inputs and outputs l Simple mounting and fastening l Code and reference code are not equal

BCISO 9001IP 65IEC 801...

Leuze electronic GmbH + Co.

A B C

15-pole plug LED indicator 15-pole plug

Postbox 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

–1–

BCL 45 MA 15

Page 2 of Leuze BCL-45 Spec Sheet

The text of page 2, from the PDF itself

Leuze electronic Specifications

Tables BCL 45

MA 15

Bar code scanner for operation with Device-Net

Connector unit and parameter memory for BCL 45

11 ... 30 V DC 5 VA 12 ... 30 V DC Imax = 100 mA

11 ... 30 V DC 2 VA 12 ... 30 V DC Imax = 100 mA

Diecast aluminum 120 x 90 x 43 mm 0.418 kg

Diecast aluminum 130 x 90 x 78 mm 0.584 kg

Electrical data Operating voltage UB Power consumption Switching input Switching output

Mechanical data Housing Dimensions (WxHxD) Weight

Environmental data Operating temperature Storage temperature Protection class Electromagnetic compatibility Air moisture

0°C ... +40°C 0°C ... +50°C -20°C ... +60°C -20°C ... +60°C IP 65 IP 65 According to IEC 801 According to IEC 801 Max. 90% rel. humidity, non-condensing

Remarks

Description The BCL 45 bar code reader is a high-speed scanner with integrated CAN-data-bus interface and is operated with the Device-Net protocol. The integrated decoder can quickly and reliably read all standard bar codes, e.g. 2/5-Interleave, Code 39 etc. In combination with the MA 15 connector unit, a simple electrical connection can be established to the CAN bus as per the Device-Net specifications. According to these specifications, it is possible by means of line loops to connect 15 to 63 bar code readers to one another in the network. The CAN system is equivalent to a master-slave system in which the master, which is in the form of a PLC, manages the data transfer. The data are exchanged by means of various messages; which message is used is dependent on the type of situation. The used messages are: I/O-Poll Command Response / Request I/O-Change of State / Cyclic Message Explicit Response / Request Message The data structures transmitted with the messages can be assembled on demand by using predefined assembly instances.

BCL 45 MA 150010–2–

Page 3 of Leuze BCL-45 Spec Sheet

The text of page 3, from the PDF itself

Leuze electronic Control elements Element

Function

Device-Net plug Terminals 1 to 5

PIN 1 and 5: PIN 2 and 4: PIN 3
voltage supply CAN-bus data lines shielding

Plug for BCL 45 Ribbon cable connection

Connects the SubD plug in the housing cover to the electronics in the MA 15 base

Service switch DIP switch 3

ON: Service mode OFF: Standard operation

Service plug 9-pole SubD plug

RS 232 interface for service/setup operation, monitoring of data in standard operation 2=RxD, 3=TxD, 5=GND

Sensor input Terminals 7, 9, 11 and 12

Input voltage 12 ... 36 V DC/AC for activation of the BCL 45

Switching output Terminals 13 to 16

Output voltage 5 ... 48 V DC for the display of e.g. "good read" or "bad read"

Data rate (1 rotary code switch)

Baud rate setting: switch position

0 = 125 kb 1 = 250 kb 2 = 500 kb >2 = baud rate can be set via software

Node address (2 rotary code switches)

Subscriber address settings (for settings, see chapter Addressing)

Reset Reset button

  • press < 4s
  • press > 4s

'warm-star' 'cold-start'

ON: OFF
on reset ('cold-start') the factory default parameter set is loaded. on reset ('cold-start') a customer-specific parameter set is loaded.

ParaDefault DIP switch 2

reserved DIP switch 4

not assigned in standard version

Electrical connection

We reserve the right to make changes

ACBDE

A Baud rate selector switch B Ribbon cable connection to the BCL C Addressing switch, tens D Addressing switch, single digits E CAN-interface connection plug

Leuze electronic GmbH + Co.

Postbox 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

–3–

BCL 45 MA 15

Page 4 of Leuze BCL-45 Spec Sheet

The text of page 4, from the PDF itself

Leuze electronic Indicators LED

ColorSignificanceMNSgreen / red

Device-Net status indicator

I/Ogreen / redScanner activeACTred

Scanner active (ACTive)

DEC

gr0010een

Decoding successful (DECoding)

Status conditions of the LEDs MNS green flashing

Device is ready, no message connection is established

MNS Device is ready, message connection is continuous light, green established MNS red flashing

Time-out of the message connection (corrected by reestablishing the message connection)

MNS continuous light, red

Serious error, e.g. a buffer overflow (corrected by switching on and off or by resetting the BCL 45)

ACT continuous light, red

Scanner is active - laser in operation

ACT flashes

During the ’autoControl’ function, a warning is output

DEC Approx. 1/2 second after successful continuous light, green completion of a decoding process.

Addressing Device-Net has the capability to link 63 subscribers to one another. These addresses are set in the MA 15 using rotary code switches. MSD rotary code switch: LSD rotary code switch:

For setting the tens digits of the subscriber address Possible values: 0 ... 6 For setting the single digits of the subscriber address Possible values: 0 ... 9

Example for subscriber 32
Set MSD rotary code switch to 3 Set LSD rotary code switch to 2

Address > 63

Address can be set via software (software selection)

Order guide Part designation

Description

Part No.

MA 15 150 BCL 45 R1 F 100 BCL 45 R1 N 100 BCL 45 SF 100 BCL 45 SM 100 BCL 45 R1 M 100

Connector unit for Device-Net slave BCL 45 Raster scanner with F optics Raster scanner with N optics Single-beam scanner with F optics Single-beam scanner with M optics Raster scanner with M optics

500 32909 500 32908 500 33621 500 35385 500 34493 500 34492

Additional scanner types on request

BCL 45 MA 150010–4–