Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 8 of 13

Bar Code Reader BCL 40 with Integrated Decoder, Connector Unit MA 10: Technical Description: 6 Installation, pages 46 to 52

Pages 46 to 52 of 94, from Bar Code Reader BCL 40 with Integrated Decoder, Connector Unit MA 10: Technical Description

The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Leuze BCL-40

Page 46

Leuze electronic

Installation RS 485 interface

Host interface module Shield 485A

485A

485B

485B

GND

GND

R S48 5 1 2 3 4 5 6

Host

Shield

485A 485A 485B 485B GND GND

1 2 3 4 5

6 up to 1200m

Figure 6.13: Connecting the MA 10 to a RS 485 Host

RS 232 interface

Host interface module RS232 1 2 3 4 5 6

Host

RXD TXD CT S RT S GND

Shield

R XD TX D C TS R TS GN D

1

2 3 4 5 6 up to 10m

Figure 6.14: Connecting the MA 10 to a RS 232 Host Notice for connecting the RS 232 interface: The wiring for RTS and CTS must only be connected, if RTS/CTS hardware-handshake is used.

44

BCL 40

Leuze electronic

Page 47

Leuze electronic

Installation

TTY interface MA 10 active / Host passive

Host interface module

Shield Shield

Ground (shield)

up to 1000m Jumper position active

Figure 6.15: Connecting the MA 10 as active subscriber to a TTY Host MA 10 passive / Host active

Shield

Host interface module Shield

TNT 35/7-24V

Jumper

Jumper Ground (shield)

up to 1000m Jumper position passive

Figure 6.16: Connecting the MA 10 as passive subscriber to a TTY Host Hints for connecting the TTY interface: The active subscriber is the one which supplies the current (20mA). Switching between active/passive on the host interface card is carried out using two jumper pairs, independent for transmit (Tx) and for receive (Rx).

Leuze electronic

BCL 40

45

Page 48

Leuze electronic

Installation

The jumpers for active/passive switching must always be changed in pairs (upper and lower jumpers in the same position). This switches the MA 10 host interface module power source and GND internally. Mixed operation is possible (transmit active/receive passive or the opposite). When switching from active to passive operation or the reverse, the wiring of the connection cable (pin order) changes.

RS 422 Interface

Host interface module R S 422

1 2 3 4 5 6

Host

R x+ R xTx+ TxG ND

TX + 1 TX - 2 RX+ 3 RX- 4 5 GND 6

Shield up to 1200m

Figure 6.17: Connecting the MA 10 to a RS 422 Host The additional pins are uniformly assigned for all MA 10 models and are described below.

Switching inputs 1 and 2 Switching inputs The MA 10 has two galvanically isolated switching inputs SE1 and SE2. • Input voltage: 12 … 36VDC/AC. • Insulation voltage: 500V Each switching input is supplied with bi-directional optical couplers and protective resistors. The switching voltage and GND can be externally applied or taken from the operating voltage VDD_SE and GND_SE.

46

BCL 40

Leuze electronic

Page 49

Leuze electronic

Installation

Terminal

Signal

Function

7

SE2_A switching input 2, connection A

8

SE2_B switching input 2, connection B

9

SE1_A switching input 1, connection A

10

SE1_B switching input 1, connection B

11

VDD_SE supply voltage, switching input, equal to V_IN device

12

GND_SE supply voltage, switching input, equal to GND_IN device

Supply voltage MA 10 / BCL 40: 18 … 36V

MA 10 External switching voltage

Optically coupled switched input to processor

TNT 35/7-24V

Figure 6.18: Connection of the switching input with an external switching voltage

Sensor/ optical sensor

Supply voltage MA 10 / BCL 40: 18 … 36V

MA 10 Optically coupled switched input to processor

Figure 6.19: Connection of the switching input without an external switching voltage

Leuze electronic

BCL 40

47

Page 50

Leuze electronic

Installation Switching outputs 1 and 2 Switching outputs

The MA 10 comes standard with two switching outputs (SA1 and SA2) that can be programmed for various switching functions using the BCL software. • Output voltage: 5 … 48VDC • Insulation voltage: 250V (only in combination with connection type b)) • Output current: Imax = 500mA (at VDD_SA = 5 … 32V) Imax = 300mA (at VDD_SA = 32 … 48V) The switching voltage can be connected in two different ways: • The operating voltage V_IN is used as the switching voltage VDD_SA (factory setting): VDD_SA = V_IN GND_SA = GND_IN • An external voltage is connected as switching voltage (galv. decoupled) VDD_SA V_IN GND_SA GND_IN Terminal

Signal

Function

13

SA2

Switching output 2

14

SA1

Switch 1

15

VDD_SA external voltage supply for switched output 5 … 48VDC

16

GND_SA external voltage supply for switched output 0VDC

Switching outputs

JL6

JL5

GND_SA

SA2 SA1

Scratch through here

VDD_SA

13 14 15 16

Scratch through here

Galvanic decoupling of the switched output Galvanic decoupling is achieved by carefully scratching through the two solder jumpers JL5 and JL6 so that there is no longer an electrical connection. The switched output is then galvanically decoupled from the operating voltage. The solder jumpers are located on the circuit board of the MA 10 directly across from the connection terminals VDD_SA and GND_SA.

Figure 6.20: Position of the solder jumpers JL5 and JL6

48

BCL 40

Leuze electronic

Page 51

Leuze electronic

Installation

V_IN JL6 solder jumper Optically coupled switched input

VDD_SA from processor

SA1/2

RL

GND_SA JL5 solder jumper GND_IN

MA 10

Figure 6.21: Operating voltage used as the switching voltage

V_IN

JL6 solder jumper open Optically coupled switched input

VDD_SA

U from processor

SA1/2 GND_SA

TNT 35/7-24V

RL

JL5 solder jumper open GND_IN

MA 10 Figure 6.22: Switching voltage connected externally (galvanically decoupled)

Controlling the function of the switching outputs The function of the switching outputs can be controlled by removing the cover to the MA 10. Sitting directly next to the connection terminals for the switching outputs are red SMD-LEDs that illuminate when the respective switching output is in the HI state (log.1). Please note that the event which sets the switching outputs must be set and activated in the software setup of the BCL 40.

Leuze electronic

BCL 40

49

Page 52

Leuze electronic

Installation Supply voltage

6.3.3

Terminal

Signal

Function

17

V_IN

Operating voltage +18 … 36VDC

18

V_IN

Operating voltage +18 … 36VDC

19

GND_IN

Operating voltage 0VDC

20

GND_IN

Operating voltage 0VDC

21

PE

Protective earth, grounding

22

PE

Protective earth, grounding

Wire Lengths and Shielding The following maximum lengths for wires and the type of shielding to be used must be observed: Connection

Max. wire length

Shielding

BCL 40 - MA 10 RS 232 / RS 485

10m absolutely required, shield meshing

BCL 40 - Host

RS 232 / RS 485

10m absolutely required, shield meshing

MA 10 - Host

RS 485

1200m absolutely required, flexible leads as twisted pairs

MA 10 - Host

RS 422

1200m absolutely required, flexible leads as twisted pairs

MA 10 - Host

RS 232

10m absolutely required, flexible leads as twisted pairs

MA 10 - Host

TTY

1000m not required loop resistance < 100

Switching inputs

10m not necessary

Switching outputs

10m not necessary

Table 6.2:

6.4

Interface

Wire Lengths and Shielding

Disassembling, Packing, Disposing Repacking For later re-use, the device is to be packed so that it is protected against shocks and dampness. Optimal protection is achieved when using the original packaging. Notice! Electrical scrap is a special waste product!Observe the locally applicable regulations regarding disposal of the product.

50

BCL 40

Leuze electronic