Page 32
Leuze electronic
Installation
6
Installation
6.1
Storage, Transportation Attention! When transporting, package the device so that it is protected against collision and humidity. Optimal protection is achieved when using the original packaging. Heed the required environmental conditions specified in the technical data.
Unpacking © Check the packaging for any damage. If damage is found, notify the post office or shipping agent as well as the supplier. © Check the delivery contents using your order and the delivery papers: • delivered quantity • device type and model as indicated on the nameplate • accessories • operating manual
Name plates
Figure 6.1:
Device nameplates MA 10 and BCL 40
© Save the original packaging for later storage or shipping. If you have any questions concerning your shipment, please contact your supplier or your local Leuze electronic sales office. © Observe the local regulations regarding disposal and packaging.
Cleaning © Clean the glass window of the BCL 40 with a soft cloth before mounting. Remove any remaining packaging from the device such as cardboard fibres and Styrofoam balls, particularly in the area of the connector socket. Attention! Do not use aggressive cleaning agents such as thinner or acetone for cleaning the device. 30
BCL 40
Leuze electronic
Page 33
Leuze electronic 6.2
Mounting
6.2.1
Types of Mounting
Installation
Accessories A wide range of mounting accessories are available for mounting the BCL 40 and MA 10: for more information see chapter 5 "Accessories / Order Designation".
Mounting the BCL 40 There are two basic types of mounting arrangements for the BCL 40: • using the dovetail groove and the corresponding mounting accessories (see figure 6.2) • using the fastening threads on the back- and underside of the devices (see chapter 4.4 "Dimensioned drawings")
Figure 6.2:
Leuze electronic
TNT 35/7-24V
Mounting device BT 56
Mounting example BCL 40 "stand alone"
BCL 40
31
Page 34
Leuze electronic
Installation Mounting BCL 40 and MA 10
You can fasten the scanner BCL 40 and connector unit MA 10 tightly together to form a single compact unit. © Plug the two devices together at the 15 pin Sub D connector. Be sure that there is no dirt in the area of the seal (this guarantees an IP 65 protection class). Insert the two M4 x 30 screws included with the connector unit MA 10 into the countersunk drill holes on the bottom side of the MA 10, screw them into the corresponding threads in the BCL 40 and tighten them down. There are three basic mounting arrangements for the BCL 40 / MA 10 unit: • using the dovetail groove of the BCL 40 or the MA 10 and the corresponding mounting accessories • using the two upper fastening threads on the rear of the BCL 40 • using the four fastening threads on the underside of the MA 10 (see chapter 4.4 "Dimensioned drawings") Notice! The cable screw glands of the MA 10 can be set either on the right or the left side of the unit. Loosen the four Phillips screws on the back side of the MA 10, carefully lift off the cover, replace it into the desired position and tighten down the four screws again. Be careful not to damage the ribbon cable.
Figure 6.3:
32
Mounting example for the combined BCL 40 / MA 10 unit
BCL 40
Leuze electronic
Page 35
Leuze electronic
Installation
Independent mounting BCL 40 / MA 10 Independent mounting of the BCL 40 and MA 10 is necessary when • the available mounting depth is not sufficient for both devices, e.g. is less than 85 mm, • or access to the mounting location of the scanner is difficult, but easy installation, commissioning and service are required, or • the operating status LEDs on the back side of the MA 10 must be easily seen.
Figure 6.4:
Mounting examples for the BCL 40 and MA 10 mounted independently
• using the dovetail groove of the BCL 40 or the MA 10 and the corresponding mounting accessories • using the fastening threads on the back- or underside of the devices • the connector unit can additionally be mounted using two M5 screws into the threaded holes that are otherwise used for fastening the BCL 40. The threaded holes have M5 threads.
Leuze electronic
BCL 40
33
TNT 35/7-24V
You can mount the individual devices in the following way as already described above:
Page 36
Leuze electronic
Installation 6.2.2
Device Arrangement Selecting a mounting location In order to select the right mounting location, several factors must be considered: • size, orientation, and position tolerance of the bar codes on the objects to be scanned • the reading field of the BCL 40 in relation to the bar-code module width • the resulting minimum and maximum reading distance from the respective reading field For specific information, please refer to chapter "Optical Data" on page 20. Notice! The best reading results are obtained when • the bar code is moved in a plane that is parallel to the reading window • the reading distance lies in the middle area of the reading field • high gloss labels or labels made from thermopaper are not used. The minimum reading distance of a bar code scanner is often decisive when using label or packaging machines due to the proximity of the scanner and labels.
Zero-distance scanner The BCL 40 M 100 is a "zero-distance" scanner, i.e. it already has a reading field width of 70 mm at a reading distance of 10 mm (module = 0.5). Labels are also read directly at the scanner window. In practice, however, this can lead to scratching of the scanner window and should be avoided. Notice! On the BCL 40, the beam is not emitted perpendicular to the cover of the housing, but with an angle of 10° towards the top. This angle is intended in order to avoid a total reflection of the laser in the case of glossy labels. For highly reflective surfaces, this angle may be widened by tilting the BCL.
34
BCL 40
Leuze electronic
Page 37
Leuze electronic
Installation
BCL 40
BCL 40 to MA 10
10˚
10˚ 120 151
10
43
10
Width: 115 + cable outlet
Width: 90 Figure 6.5:
84
Minimum space requirements for installation
Mounting location • maintaining the required environmental conditions (humidity, temperature), • possible soiling of the reading window due to liquids, abrasion by boxes, or packaging material residues, • lowest possible chance of damage to the scanner by mechanical collision or jammed parts.
Leuze electronic
BCL 40
35
TNT 35/7-24V
© When selecting a mounting location, pay attention to
Page 38
Leuze electronic
Installation Application example
Optical sensor BCL 40
MA 10
Connection cable BCL 40 / MA 10 Voltage supply
Connection cable MA 10 / opt. sensor
Host interface
Figure 6.6:
Application example "conveyor chain"
With its high scan rate of 1200 scans/s, the BCL 40 is particularly well suited for use with high-speed conveyor belts.
36
BCL 40
Leuze electronic