Page 18
Leuze electronic
Specifications
4
Specifications
4.1
Technical Data BCL 40 Standard Version Optical Data Light source Scanning rate Resolution Beam deflection Reading distance Reading field opening Grid (R1) Grid field
Single line (S) Optical window Laser safety class Code types Software features
Electrical data Interface type
Baud rate Data formats
Protocols
Ports LED green
16
Laser diode 650nm BCL with N, M, F optics: 1200scans/s BCL with L optics: 900scans/s 0.1mm … 1.2mm module width by means of rotating polygon mirror wheel 0 … 700mm (depending on type of optics: N, M, F, L), see chapter 4.5.4 "Reading curves BCL 40 standard version" 70mm at a distance of approx. 10mm (see chapter 4.5.4 "Reading curves BCL 40 standard version") 8 lines specified is the area from the first to the last laser beam as a function of distance to the scanner 22mm at 100mm scanner distance 33mm at 200mm scanner distance 45mm at 300mm scanner distance 65mm at 500mm scanner distance 95mm at 800mm scanner distance 1 line glass with scratch-resistant Indium coating 2 2/5 Interleaved; Code 39; Code 128; EAN 8; 13; EAN 128; UPC; Codabar; Add-On for EAN / UPC selectable output format, autoConfig, autoControl, reference code comparison, multiple read, real time decoding, adjustment mode, diagnosis, reading gate control, control of switching inputs and switching outputs, etc. can be switched between RS 232 and RS 485, additional service interface (RS 232) TTY / RS 422 optional with MA 10 110 … 57600Bd (host interface only) data bits: 7, 8, 9 parity: None, Even, Odd Stop bit: 1, 2 with/without frame protocol ACK/NAK, 3964 (R) RK 512, RTS/CTS X ON / X OFF, multiNet plus 1 switching input device ready (Power On)
BCL 40
Leuze electronic
Page 19
Leuze electronic Switching input
Operating voltage Power consumption
12 … 36VDC/AC voltage, selectable galvanic isolation or supplied operating voltage, max. insulation voltage: 250V (with galvanic isolation) 18 … 36V 5VA max.
Mechanical data Protection class Weight Dimensions (WxHxD) Housing
IP 65 approx. 430g 120 x 90 x 43mm diecast aluminium
Environmental data Ambient temperature (operation/storage) Air humidity Vibration Shock EMC Table 4.1:
4.2
Specifications
0°C … +40°C / -20°C … +60°C max. 90% rel. humidity, non-condensing IEC 68.2.6 IEC 68.2.27 IEC 801
General Specifications BCL 40 Standard Version
Technical Data BCL 40 with Heating
Optical Data Light source Resolution Reading distance Reading field opening
Laser diode 660nm 0.25mm … 1.0mm module width 0 … 630mm (depending on type of optics: M, F, L) see chapter 4.5.5 "Reading curves BCL 40 with heating" Depending on the distance, the reading curve is typically approx. 20 … 70mm narrower see chapter 4.5.5 "Reading curves BCL 40 with heating"
Electrical data Operating voltage Power consumption
24VDC ± 2V 10W max.
Mechanical data Weight Dimensions (WxHxD)
approx. 500g 120 x 90 x 52mm
Environmental data Ambient temperature (operation/storage) Table 4.2:
Leuze electronic
-40°C … +30°C/-20°C … +60°C
General Specifications BCL 40 with Heater
BCL 40
17
TNT 35/7-24V
The following table is limited to the data which are different than those specified for the standard model.
Page 20
Leuze electronic
Specifications 4.3
Technical Data MA 10 Mechanical data Housing Dimensions (WxHxD) Weight Protection class Interfaces Type (optional)
Service interface Inputs/outputs 2 switched inputs 2 switched outputs Power supply Operating voltage Power consumption Environmental data Ambient temperature (operation/storage) Air humidity Vibration Shock EMC Table 4.3:
18
Diecast aluminium 130 x 90 x 78mm approx. 740g IP 65 RS 232, with galvanic isolation RS 422, with galvanic isolation RS 485, with galvanic isolation TTY, with galvanic isolation RS 232 internal, 9 pin Sub D plug, male galvanically isolated,with supply voltage terminal for sensors 12 … 36VDC/AC, insulation voltage 500V can be operated galvanically isolated or not isolated switching voltage 5 … 48V DC, max. load 500mA 18 … 36VDC 2VA max. 0°C … +50°C/-20°C … +60°C max. 90% rel. humidity, non-condensing IEC 68.2.6 IEC 68.2.27 IEC 801
General Specifications MA 10
BCL 40
Leuze electronic
Page 21
Leuze electronic 4.4
Specifications
Dimensioned drawings
Rear view
Plan view
120 =110
43
Dimensioned drawing BCL 40
Plan view
Rear view TNT 35/7-24V
Figure 4.1:
=80
90
M 4x6 (4x)
78 22.5 130
10
Figure 4.2:
Leuze electronic
70
90
116
M 4 (4x)
Dimensioned drawing MA 10
BCL 40
19
Page 22
Leuze electronic
Specifications 4.5
Optical Data The range at which the bar code can be read by the BCL 40 (the so-called reading field) depends not only on the quality of the printed bar code but also on its dimensions and the incident angle of the scanner beam. Therefore, above all, the module of a bar code is decisive for the size of the reading field. M=
Module: The narrowest line or space of a bar code in mm ZB = Wide elements: Wide lines and spaces are a multiple (ratio) of the module Module x Ratio = ZB (Normal Ratio 1:2.5) BZ = Quiet zone: The quiet zone should be at least 10 times the module, but not less than 2.5 mm. L = Code length: The length of the bar code in mm including the start and stop characters. The quiet zone is included depending on the code definition. SL = Element length: Height of the elements in mm
Figure 4.3:
The most important characteristics of a bar code
Notice! A rule of thumb: The smaller the module of the bar code is, the smaller the maximum reading distance and reading field width will be. © Therefore, when selecting a mounting location and/or the bar code label, take into account the different reading characteristics of the scanner with various bar code modules. For different reading tasks, the BCL 40 is available in various versions, both as a raster scanner and as a single line scanner. The device specifications are given in the following table and accompanying graphic.
20
BCL 40
Leuze electronic
Page 23
Leuze electronic 4.5.1
Type overview Model
BCL 40 R1 N 100 BCL 40 S N 100 BCL 40 R1 M 100 BCL 40 S M 100 BCL 40 R1 F 100 BCL 40 S F 100 BCL 40 R1 L 100 BCL 40 S L 100 Table 4.4:
4.5.2
Specifications
Range (mm)
Module/ resolution (mm)
20 …80
0.1 … 0.5
Scanning Scanner type rate (Sweep (scan/s) principle) 1200
0 … 250
0.2 … 1.0
1200
50 …500
0.3 … 1.0
1200
250 … 700
0.5 … 1.2
900
Raster
Part No.
500 29678
Single line
500 29679
Raster
500 26111
Single line
500 28920
Raster
500 28168
Single line
500 28921
Raster
500 28427
Single line
500 28922
Type overview
Sweep principle Raster (R1) 8 parallel lines scan the label. Areas of use: • when the bar code is printed in the conveying direction ("picket fence arrangement") TNT 35/7-24V
• when reading through plastic sheeting or from reflecting surfaces • when reading stationary objects
Raster scanner material flow direction
Figure 4.4:
Sweep principle of the raster scanner
Notice! The scanning rate is distributed over 8 lines per scan, i.e. the scanning rate per raster line is 1/8 the total scanning rate. Leuze electronic
BCL 40
21
Page 24
Leuze electronic
Specifications Single line (S) 1 line scans the label. Areas of use:
• when the bar code is printed in the conveying direction ("ladder arrangement") • with bar codes having very short bar lengths
Line scanner material flow direction
Figure 4.5:
4.5.3
Sweep principle for the line scanner
Optics variants The BCL 40 is available with four different types of optics (N, M, F, L) that differ in range and resolution (see chapter 4.5.1 "Type overview"). Optic N: Zero to very short scanning ranges for very small modules. Optic M: Zero to short scanning ranges for small to middle-sized modules. Optic F: Zero to short scanning ranges for small to middle-sized modules. Optic L: Middle to large scanning ranges with middle to large sized modules. The following graphic displays the scanning curves of the various BCL models. Notice! Please note that the actual scanning curves can vary due to factors such as label material, print quality, reading angle, print contrast, etc.
22
BCL 40
Leuze electronic
Page 25
Leuze electronic 4.5.4
Specifications
Reading curves BCL 40 standard version
60 50 40 30 20 10 m = 0,127 m = 0,2
0 20
40
60
80
100
-10 -20 -30 -40 -50 -60
BCL 40 R1 N100 and BCL 40 S N100
125 100
TNT 35/7-24V
75 50 25 m = 0,3 m = 0,5
0 20
40
60
80
100
120
140
160
180
200
220
240
260
-25 -50 -75 -100 -125
BCL 40 R1 M100 and BCL 40 S M100 Notice: All data in ’mm’, m = module width
Figure 4.6: Leuze electronic
Reading curves BCL 40 standard version, optic variants N and M BCL 40
23
Page 26
Leuze electronic
Specifications
125 100 75 50 m = 0,8 25 m = 0,3 m = 0,5
0 50
100
150
200
250
300
350
400
450
500
-25 -50 -75 -100 -125
BCL 40 R1 F100 and BCL 40 S F100
125 100 75 50 25 m = 0,5 m = 0,7
0 100
200
300
400
500
600
700
-25 -50 -75 -100 -125
BCL 40 R1 L100 and BCL 40 S L100
Notice: All data in ’mm’, m = module width
Figure 4.7: 24
Reading curves BCL 40 standard version, optic variants F and L BCL 40
Leuze electronic
Page 27
Leuze electronic 4.5.5
Specifications
Reading curves BCL 40 with heating 80 60 m = 0,5 40 m = 0,3 20 0 20
40
60
80
100
120
140
160
180
200
220
240
-20 -40 -60 -80
BCL 40 R1 M100 H and BCL 40 S M100 H
125 m = 0,7
TNT 35/7-24V
75 m = 0,5
25
200 -25
250
300
350
400
450
500
550
600
650
700
-75
-125
BCL 40 R1 L100 H and BCL 40 S L100 H
Notice: All data in ’mm’, m = module width
Figure 4.8: Leuze electronic
Reading curves BCL 40 with heating, optic variants M and L BCL 40
25
Page 28
Leuze electronic
Specifications
125 100 75 m = 0,8 m = 0,5
50 25 0 50
100
150
200
250
300
350
400
450
500
-25 -50 -75 -100 -125
BCL 40 R1 F100 H and BCL 40 S F100 H Notice: All data in ’mm’, m = module width
Figure 4.9:
26
Reading curves BCL 40 with heating, optic variant F
BCL 40
Leuze electronic