Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 13

Bar Code Reader BCL 40 with Integrated Decoder, Connector Unit MA 10: Technical Description: 4 Specifications

Pages 18 to 28 of 94, from Bar Code Reader BCL 40 with Integrated Decoder, Connector Unit MA 10: Technical Description

The original document is the PDF (1.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Leuze BCL-40

Page 18

Leuze electronic

Specifications

4

Specifications

4.1

Technical Data BCL 40 Standard Version Optical Data Light source Scanning rate Resolution Beam deflection Reading distance Reading field opening Grid (R1) Grid field

Single line (S) Optical window Laser safety class Code types Software features

Electrical data Interface type

Baud rate Data formats

Protocols

Ports LED green

16

Laser diode 650nm BCL with N, M, F optics: 1200scans/s BCL with L optics: 900scans/s 0.1mm … 1.2mm module width by means of rotating polygon mirror wheel 0 … 700mm (depending on type of optics: N, M, F, L), see chapter 4.5.4 "Reading curves BCL 40 standard version" 70mm at a distance of approx. 10mm (see chapter 4.5.4 "Reading curves BCL 40 standard version") 8 lines specified is the area from the first to the last laser beam as a function of distance to the scanner 22mm at 100mm scanner distance 33mm at 200mm scanner distance 45mm at 300mm scanner distance 65mm at 500mm scanner distance 95mm at 800mm scanner distance 1 line glass with scratch-resistant Indium coating 2 2/5 Interleaved; Code 39; Code 128; EAN 8; 13; EAN 128; UPC; Codabar; Add-On for EAN / UPC selectable output format, autoConfig, autoControl, reference code comparison, multiple read, real time decoding, adjustment mode, diagnosis, reading gate control, control of switching inputs and switching outputs, etc. can be switched between RS 232 and RS 485, additional service interface (RS 232) TTY / RS 422 optional with MA 10 110 … 57600Bd (host interface only) data bits: 7, 8, 9 parity: None, Even, Odd Stop bit: 1, 2 with/without frame protocol ACK/NAK, 3964 (R) RK 512, RTS/CTS X ON / X OFF, multiNet plus 1 switching input device ready (Power On)

BCL 40

Leuze electronic

Page 19

Leuze electronic Switching input

Operating voltage Power consumption

12 … 36VDC/AC voltage, selectable galvanic isolation or supplied operating voltage, max. insulation voltage: 250V (with galvanic isolation) 18 … 36V 5VA max.

Mechanical data Protection class Weight Dimensions (WxHxD) Housing

IP 65 approx. 430g 120 x 90 x 43mm diecast aluminium

Environmental data Ambient temperature (operation/storage) Air humidity Vibration Shock EMC Table 4.1:

4.2

Specifications

0°C … +40°C / -20°C … +60°C max. 90% rel. humidity, non-condensing IEC 68.2.6 IEC 68.2.27 IEC 801

General Specifications BCL 40 Standard Version

Technical Data BCL 40 with Heating

Optical Data Light source Resolution Reading distance Reading field opening

Laser diode 660nm 0.25mm … 1.0mm module width 0 … 630mm (depending on type of optics: M, F, L) see chapter 4.5.5 "Reading curves BCL 40 with heating" Depending on the distance, the reading curve is typically approx. 20 … 70mm narrower see chapter 4.5.5 "Reading curves BCL 40 with heating"

Electrical data Operating voltage Power consumption

24VDC ± 2V 10W max.

Mechanical data Weight Dimensions (WxHxD)

approx. 500g 120 x 90 x 52mm

Environmental data Ambient temperature (operation/storage) Table 4.2:

Leuze electronic

-40°C … +30°C/-20°C … +60°C

General Specifications BCL 40 with Heater

BCL 40

17

TNT 35/7-24V

The following table is limited to the data which are different than those specified for the standard model.

Page 20

Leuze electronic

Specifications 4.3

Technical Data MA 10 Mechanical data Housing Dimensions (WxHxD) Weight Protection class Interfaces Type (optional)

Service interface Inputs/outputs 2 switched inputs 2 switched outputs Power supply Operating voltage Power consumption Environmental data Ambient temperature (operation/storage) Air humidity Vibration Shock EMC Table 4.3:

18

Diecast aluminium 130 x 90 x 78mm approx. 740g IP 65 RS 232, with galvanic isolation RS 422, with galvanic isolation RS 485, with galvanic isolation TTY, with galvanic isolation RS 232 internal, 9 pin Sub D plug, male galvanically isolated,with supply voltage terminal for sensors 12 … 36VDC/AC, insulation voltage 500V can be operated galvanically isolated or not isolated switching voltage 5 … 48V DC, max. load 500mA 18 … 36VDC 2VA max. 0°C … +50°C/-20°C … +60°C max. 90% rel. humidity, non-condensing IEC 68.2.6 IEC 68.2.27 IEC 801

General Specifications MA 10

BCL 40

Leuze electronic

Page 21

Leuze electronic 4.4

Specifications

Dimensioned drawings

Rear view

Plan view

120 =110

43

Dimensioned drawing BCL 40

Plan view

Rear view TNT 35/7-24V

Figure 4.1:

=80

90

M 4x6 (4x)

78 22.5 130

10

Figure 4.2:

Leuze electronic

70

90

116

M 4 (4x)

Dimensioned drawing MA 10

BCL 40

19

Page 22

Leuze electronic

Specifications 4.5

Optical Data The range at which the bar code can be read by the BCL 40 (the so-called reading field) depends not only on the quality of the printed bar code but also on its dimensions and the incident angle of the scanner beam. Therefore, above all, the module of a bar code is decisive for the size of the reading field. M=

Module: The narrowest line or space of a bar code in mm ZB = Wide elements: Wide lines and spaces are a multiple (ratio) of the module Module x Ratio = ZB (Normal Ratio 1:2.5) BZ = Quiet zone: The quiet zone should be at least 10 times the module, but not less than 2.5 mm. L = Code length: The length of the bar code in mm including the start and stop characters. The quiet zone is included depending on the code definition. SL = Element length: Height of the elements in mm

Figure 4.3:

The most important characteristics of a bar code

Notice! A rule of thumb: The smaller the module of the bar code is, the smaller the maximum reading distance and reading field width will be. © Therefore, when selecting a mounting location and/or the bar code label, take into account the different reading characteristics of the scanner with various bar code modules. For different reading tasks, the BCL 40 is available in various versions, both as a raster scanner and as a single line scanner. The device specifications are given in the following table and accompanying graphic.

20

BCL 40

Leuze electronic

Page 23

Leuze electronic 4.5.1

Type overview Model

BCL 40 R1 N 100 BCL 40 S N 100 BCL 40 R1 M 100 BCL 40 S M 100 BCL 40 R1 F 100 BCL 40 S F 100 BCL 40 R1 L 100 BCL 40 S L 100 Table 4.4:

4.5.2

Specifications

Range (mm)

Module/ resolution (mm)

20 …80

0.1 … 0.5

Scanning Scanner type rate (Sweep (scan/s) principle) 1200

0 … 250

0.2 … 1.0

1200

50 …500

0.3 … 1.0

1200

250 … 700

0.5 … 1.2

900

Raster

Part No.

500 29678

Single line

500 29679

Raster

500 26111

Single line

500 28920

Raster

500 28168

Single line

500 28921

Raster

500 28427

Single line

500 28922

Type overview

Sweep principle Raster (R1) 8 parallel lines scan the label. Areas of use: • when the bar code is printed in the conveying direction ("picket fence arrangement") TNT 35/7-24V

• when reading through plastic sheeting or from reflecting surfaces • when reading stationary objects

Raster scanner material flow direction

Figure 4.4:

Sweep principle of the raster scanner

Notice! The scanning rate is distributed over 8 lines per scan, i.e. the scanning rate per raster line is 1/8 the total scanning rate. Leuze electronic

BCL 40

21

Page 24

Leuze electronic

Specifications Single line (S) 1 line scans the label. Areas of use:

• when the bar code is printed in the conveying direction ("ladder arrangement") • with bar codes having very short bar lengths

Line scanner material flow direction

Figure 4.5:

4.5.3

Sweep principle for the line scanner

Optics variants The BCL 40 is available with four different types of optics (N, M, F, L) that differ in range and resolution (see chapter 4.5.1 "Type overview"). Optic N: Zero to very short scanning ranges for very small modules. Optic M: Zero to short scanning ranges for small to middle-sized modules. Optic F: Zero to short scanning ranges for small to middle-sized modules. Optic L: Middle to large scanning ranges with middle to large sized modules. The following graphic displays the scanning curves of the various BCL models. Notice! Please note that the actual scanning curves can vary due to factors such as label material, print quality, reading angle, print contrast, etc.

22

BCL 40

Leuze electronic

Page 25

Leuze electronic 4.5.4

Specifications

Reading curves BCL 40 standard version

60 50 40 30 20 10 m = 0,127 m = 0,2

0 20

40

60

80

100

-10 -20 -30 -40 -50 -60

BCL 40 R1 N100 and BCL 40 S N100

125 100

TNT 35/7-24V

75 50 25 m = 0,3 m = 0,5

0 20

40

60

80

100

120

140

160

180

200

220

240

260

-25 -50 -75 -100 -125

BCL 40 R1 M100 and BCL 40 S M100 Notice: All data in ’mm’, m = module width

Figure 4.6: Leuze electronic

Reading curves BCL 40 standard version, optic variants N and M BCL 40

23

Page 26

Leuze electronic

Specifications

125 100 75 50 m = 0,8 25 m = 0,3 m = 0,5

0 50

100

150

200

250

300

350

400

450

500

-25 -50 -75 -100 -125

BCL 40 R1 F100 and BCL 40 S F100

125 100 75 50 25 m = 0,5 m = 0,7

0 100

200

300

400

500

600

700

-25 -50 -75 -100 -125

BCL 40 R1 L100 and BCL 40 S L100

Notice: All data in ’mm’, m = module width

Figure 4.7: 24

Reading curves BCL 40 standard version, optic variants F and L BCL 40

Leuze electronic

Page 27

Leuze electronic 4.5.5

Specifications

Reading curves BCL 40 with heating 80 60 m = 0,5 40 m = 0,3 20 0 20

40

60

80

100

120

140

160

180

200

220

240

-20 -40 -60 -80

BCL 40 R1 M100 H and BCL 40 S M100 H

125 m = 0,7

TNT 35/7-24V

75 m = 0,5

25

200 -25

250

300

350

400

450

500

550

600

650

700

-75

-125

BCL 40 R1 L100 H and BCL 40 S L100 H

Notice: All data in ’mm’, m = module width

Figure 4.8: Leuze electronic

Reading curves BCL 40 with heating, optic variants M and L BCL 40

25

Page 28

Leuze electronic

Specifications

125 100 75 m = 0,8 m = 0,5

50 25 0 50

100

150

200

250

300

350

400

450

500

-25 -50 -75 -100 -125

BCL 40 R1 F100 H and BCL 40 S F100 H Notice: All data in ’mm’, m = module width

Figure 4.9:

26

Reading curves BCL 40 with heating, optic variant F

BCL 40

Leuze electronic