Page 10
Leuze electronic
Safety Notices
2
Safety Notices
2.1
Safety Standards The bar code readers BCL 40 and the connector unit MA 10 have been developed, produced and tested subject to the applicable safety standards. They correspond to the state of the art.
2.2
Intended Use Attention! The protection of personnel and the device cannot be guaranteed if the device is operated in a manner not corresponding to its intended use. Bar code readers of the type BCL 40 are conceived as stationary, high-speed scanners with integrated decoders for all current bar codes used for automatic object recognition. The connector and interface unit MA 10 simplifies the connection of the bar code reader of type BCL 40 and adapts to various host interfaces. Connection to other bar code readers is not authorised. In particular, unauthorised use includes: • rooms with explosive atmospheres • operation for medical purposes
Fields of application The bar code readers BCL 40 with optional connector unit MA 10 are conceived particularly for the following fields of application: • • • • labelling and packaging machines automatic analysers space-critical bar code reading tasks storage and conveying technologies, in particular for object identification on fast-moving conveyor belts • pharmaceutical industry
8
BCL 40
Leuze electronic
Page 11
Leuze electronic 2.3
Safety Notices
Working Safely Attention Laser Radiation! The BCL 40 are laser devices of the Laser Protection Class 2. Do not look directly into the laser beam. Observe the applicable legal and local regulations for the operation of laser units. Attention! Access to or changes on the device, except where expressly described in this operating manual, is not authorised.
Safety Regulations Observe the locally applicable legal regulations and the rules of the employer’s liability insurance association.
Qualified Personnel
TNT 35/7-24V
Mounting, commissioning and maintenance of the device must only be carried out by qualified personnel. Electrical work must be carried out by a certified electrician.
Leuze electronic
BCL 40
9
Page 12
Leuze electronic
Description
3
Description
3.1
The Bar Code Readers BCL 40 The bar code reader BCL 40 is a high-speed scanner with integrated decoder for all bar codes currently in use, e.g. 2/5 Interleaved, EAN, etc. The many possible configurations of the device allow its adaptation to a multitude of reading tasks. Due to its compact size and short minimum reading distance, the BCL 40 can also be used in very compact spaces. Together with the connector unit MA 10, it can easily be adapted for use with various interfaces, thus allowing additional processing by other systems. The MA 10 connector unit can also be used to network together several BCL 40 devices and to simplify electrical installation. On demand, the BCL 40 can be equipped with an integrated heater. This variant is used primarily in low-temperature and outdoor applications. The optional heater is constructed such that no heat transfer occurs between the separately mounted technical unit and the scanner housing. In addition, the front cover of the device is heated, preventing the formation of condensation which would affect the reading function. The reading curves differ with respect to the standard type in the construction of the front cover, which is modified by heating filaments.
3.2
Features of the BCL 40
3.2.1
Performance features • • • • • • • • • • • •
10
Compact device dimensions (W x H x D) 90 x 120 x 43mm Reading height of 70 mm at a distance of 10mm Maximum reading distance up to 700mm (depending on type of optics) Raster or line scanner (R1 = raster, S = single line) max. 1200scans/s A switched input for triggering a read process using sensors Automatic monitoring of the read quality with the "autoControl" function Automatic recognition of the bar code type using "autoConfig" All device parameters can be set by software Heavy-duty housing of protection class IP 65 with corresponding cable RS 232 or RS 485 interface to host Extensive formatting possibilities for data output Reference code (comparison code)
BCL 40
Leuze electronic
Page 13
Leuze electronic 3.2.2
Description
Added features with MA 10 • Device status display with 4 LEDs • RS 485 interface with electrical isolation for networking several devices • Alternative interface RS 232, RS 422 or TTY using a selectable interface module with electrical isolation for directly connecting to the host • Two hardware switched outputs for status signals • Additional switched input for the definition of reference code 1 • Simple electrical connection via double terminal clamps, i.e. both the power supply and the interface circuits can easily be connected in series. • Heavy-duty housing of protection class IP 65 • 2 parameter sets can be stored locally in the MA 10 (current parameter set, customer-specific parameter set) • Built-in RS 232 service interface for fast commissioning or troubleshooting on site using a PC or programming device • Switch for the "autoConfig" function
3.2.3
Modular Concept BCL 40 "Stand alone" The bar code reader BCL 40 can be operated as an individual "stand alone" (€) device. Electrical connection of the power supply, interface and switched input are centrally made via a 15 pin SubD socket.
BCL 40 with MA 10 When using several BCL 40 units or under rough environment conditions, the installation of one connector unit MA 10 for each BCL 40 unit is recommended. Electrical connection, commissioning, and service can be comfortably carried out in a short period of time. The BCL 40 and MA 10 can be mounted directly together (ó) or arranged separately next to each other. When mounted separately (ì), the two units are connected by a cable. Protection class IP 65 is maintained when the sealed accessory cable is used (see chapter 5 "Accessories / Order Designation").
Leuze electronic
BCL 40
11
TNT 35/7-24V
For connection, it is best to use the 15 conductor connection cable from Leuze. The requirements for protection class IP 65 are fulfilled when using this cable only (see chapter 5 "Accessories / Order Designation").
Page 14
Leuze electronic
Description
€ BCL 40 as "Stand alone"-device
ó BCL 40 with the connector unit MA 10 mounted together
ì BCL 40 and MA 10 mounted separately and connected together by a cable
Figure 3.1:
Possible combinations of the BCL 40 / MA 10
Networking Up to 31 BCL 40 bar code readers can be networked together using the connector unit MA 10 (with interface module RS 485). The devices are interconnected by connecting the individual RS 485 interfaces in parallel.
multiNet plus In the Leuze multiNet plus, the individual network devices sequentially transfer their data to the network master MA 30 when requested ("polling"). The master station can also be fitted with an BCL 40, making it a complete scanner station which also controls the network. Each network device declared as a slave maintains a device address which is set in the respective MA 10 with a coding switch. If the reader unit is exchanged (BCL), the device address and all settings in the MA 10 are maintained. The master then transmits the data of all network devices via its host interface to a primary PLC control system or a computer, i.e. it "collects" the scanner data in the network and transmits them to an interface on the host computer. This reduces interface costs (CPs) and time programming the software. The MA 30/31 are suitable for use as network master devices.
12
BCL 40
Leuze electronic
Page 15
Leuze electronic
Description
Sensor Slave MA 10
Sensor
RS 232 RS 422 RS 485 or TTY
Slave MA 10
-Backup parameters
Slave MA 10 Sensor
Network master multiNet plus MA 30
Sensor
Voltage supply
Figure 3.2:
Networking possibilities using the multiNet plus
Two-wire RS 485 The Leuze MultiNet plus is optimised for fast transmission of scanner data to a primary host computer. The multiNet plus physically consists of a two-wire RS 485 interface through which the multiNet plus software protocol is controlled. Thus network connection is very simple and inexpensive: the network connection is simply passed through to the next slave.
Interface modules Shielded, twisted pair conductors should be used for the multiNet. This allows a total network length of up to 1200m. Connection of the network to the primary computer is made via the host interface of the MA 30 which can be equipped with 4 different physical interface modules. Modules for RS 232, RS 422, TTY and RS 485 are available.
Leuze electronic
BCL 40
13
TNT 35/7-24V
RS 485
Page 16
Leuze electronic
Description 3.3
Construction
3.3.1
BCL 40/device construction
Dovetail fastening grooves
Reading window
15-pin sub-D connector on the underside of the unit
4 fastening threads M4 on the rear of the device
Figure 3.3:
14
BCL 40/device construction
BCL 40
Leuze electronic
Page 17
Leuze electronic 3.3.2
Description
Device construction MA 10 Mounting holes for the BCL 40 with M4 screws
4 Status-LEDs on the rear
Cable screw glands PG11 for the power supply
Cable screw glands PG11 for the power supply
15 pin Sub-D connector
4 fastening threads M4 on the base of the device Dovetail fastening grooves
Figure 3.4:
Connector unit MA 10
Device variations MA 10 • • • •
MA 10 100 with host interface module RS 485 MA 10 110 with host interface module RS 232 MA 10 120 with host interface module TTY MA 10 130 with host interface module RS 422
All modules are galvanically isolated, i.e. they are EMC interference protected and immune to differences in voltage potentials across long cable lengths. Notice! Only the type MA 10 100 can be used as a multiNet slave unit.
Leuze electronic
BCL 40
15
TNT 35/7-24V
The MA 10 is available in four models: