Page 1
Kramer Electronics, Ltd.
ah
KRAMER
USER MANUAL
Model: VP-43xl
Interface Converter
Page 2
Contents
Contents 1 2 3 4 5 5.1 5.2 5.3
Introduction Getting Started Overview Your Interface Converter Connecting a Interface Converter Unit Connecting a PC (RS-232) Connecting the RS-485 Connector Understanding the RS-422 Connector
1 1 1 3 4 5 5 6
5.4 5.5 5.6
Connecting the RS-422 Connector Dipswitch Settings Interface Converter Unit Configuration
9 9 10
Using the Interface Converter as a Range Extender Technical Specifications
13 14
5.3.1 5.3.2 5.3.3 5.3.4 5.3.5 5.3.6
5.6.1
6 7
Signal Terminology Bi-directional Signals Communication Method via a DB9 Connector Device Definition Port Definitions More Than One Slave
Fully transparent RS-232 Daisy Chaining
6 6 6 7 7 7
11
Figures Figure 1: Range of Bi-directional Converted Interface Signals Figure 2: VP-43xl Interface Converter Figure 3: Connecting a PC without using a Null-modem Adapter Figure 4: RS-485 Connector PINOUT Figure 5: Bi-directional Signals I Figure 6: Bi-directional Signals II Figure 7: Communication between a Master and several Slaves Figure 8: SETUP Dipswitches Figure 9: PC control of 2 Switchers via RS-232 and RS-485 Figure 10: PC control of up to 32 Switchers via RS-485 Figure 11: PC control of a Broadcasting VTR Unit via RS-422 Figure 12: PC control of Broadcasting VTR Units via RS-232 and RS-422 Figure 13: Control of up to 32 VTR Units via RS-485 and RS-422 Figure 14: Control via RS-485, RS-422 and RS-232 Figure 15: Extending the Range using a Pair of Interface Converter Units
2 4 5 5 6 6 8 10 10 11 11 12 12 13 14
Tables Table 1: Features and Functions of the VP-43xl Interface Converter Table 2: Baud Rate Selection Table 3: SETUP Dipswitch Definitions Table 4: Technical Specifications of the VP-43xl Interface Converter
4 9 9 14 i
Page 3
Introduction
1
Introduction Dedication by Kramer Electronics since 1981, to the development and manufacture of high quality video/audio equ ipment, makes the Kramer line an integral part of the finest production and presentation facilities in the world. In recent years, Kramer has redesigned and upgraded most of the line, making the best even better! The Kramer line of professional video/audio electronics is one of the most versatile and complete available, and is a true leader in terms of quality, workmanship, price/performance ratio and innovation. In addition to our high quality accessories, like the VP-43xl Interface Converter, we also offer excellent switchers and matrices, distribution amplifiers, presentation processors, interfaces, remote controllers and computer-related products. Congratulations on purchasing your Kramer Tools VP-43xl Interface Converter. This product is ideal for: Interconnecting units with different control interfaces Extending the limited range of RS -232 by converting to RS-422 or RS-485 Daisy-chaining RS-422 devices The package includes the following items: VP-43xl Interface Converter Power adapter (12V DC Input) Mounting bracket This user manual Kramer concise product catalog/CD
2
Getting Started We recommend that you: Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual
3
Overview Your easy to use VP-43xl Interface Converter incorporates the 3 major video and presentation industry interfaces: RS -232, RS-422 and RS-485. The
1
Page 4
Overview 1
RS-232 interface is a computer interface with a range of about 25 meters used for a point-to-point connection. The RS-4222 interface is commonly used in broadcasting equipment and has a range of 1200 meters usually used for a point-to-point connection (but can be used for transmitting from one unit to several Slave receivers). The RS-4853 interface has a range of 1200 meters and lets you connect up to 32 devices to one line. The adjustment-free VP-43xl Interface Converter accepts serial data on one interface, automatically translating it simultaneously to the other 2 interfaces with the same speed and format. Each way is bi-directional, as Figure 1 illustrates:
Figure 1: Range of Bi-directional Converted Interface Signals
The VP-43xl Interface Converter can control equipment with different interfaces, from a piece of equipment with a single interface 4. In particular, the VP-43xl Interface Converter lets you control equipment with: An RS-422 or RS-485 interface directly from the COM port (RS-232) on your PC5 An RS-232 or RS-485 interface from a controller with an RS-422 interface An RS-232 or RS-422 interface from any modern equipment with an RS-485 interface
1 The RS-232 interface meets the TIA/EIA-232-F standard 2 The RS-422 interface meets the TIA/EIA-422-B standard 3 The RS-485 interface meets the TIA/EIA-485-A standard 4 For example, you can control a switcher with a RS-232 interface and a broadcasting VTR with a RS-422 interface, from a controller with an RS-485 interface 5 Without requiring a PC interface card adapter
2
KRAMER ELECTRONICS, LTD.
Page 5
Your Interface Converter
The VP-43xl Interface Converter: Is a Plug & Play device 1 Avoids the limitation of RS-232 and RS-422 interfaces that allow only a point-to-point connection (that is, one device per port) Enables fully transparent RS-232 daisy-chaining2 Supports varied setup arrangements 3 Lets you connect up to 32 units via the RS-485 interface 4 Can extend the range between a PC and a switcher to up to 1200 meters 5 The VP-43xl Interface Converter lets you choose a: Connection with or without a Null -modem adapter for RS-232 Baud rate from a choice of 5 rates 6 RS-422 Master/Slave and a Straight/Inverse interface Achieving the best performance means: Connecting only good quality connection cables, thus avoiding interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables) Avoiding interference from neighboring electrical appliances that may adversely influence signal quality and positioning your VP-43xl Interface Converter unit in a location free from moisture and away from excessive sunlight and dust
4
Your Interface Converter Figure 1 and Table 1 define the VP-43xl Interface Converter unit:
1 Unlike many control interfaces, it is not software reliant 2 Using multiple VP-43xl Interface Converter units, as section 5.6.1 describes 3 As the illustrations in section 5 show 4 As Figure 10, Figure 13 and Figure 14 illustrate 5 When connecting a pair of VP-43xl Interface Converter units via RS -485, as section 6 describes 6 1,200 baud, 2,400 baud, 9,600 baud, 19,200 baud, or 38,400 baud
3
Page 6
Connecting a Interface Converter Unit
Figure 2: VP-43xl Interface Converter Table 1: Features and Functions of the VP-43xl Interface Converter # 1 2 3 4 5 6 7
5
Feature Function RS-232 in DB9F Port Connect to the DB 9 COM PORT 1-4 on the PC or controller RS-232 out DB9F Port Connect to the RS-232 DB 9 port on the switcher, VTR, mixer or to the RS-232 in port on the next Interface Converter in the line RS-422 DB9F Port Connect to the RS-422 port on the controller or broadcasting VTR 12V DC +12V DC connector for powering the unit ON LED Illuminates when receiving power SETUP Set the dipswitches RS-485 Connect to the RS-485 port on the switcher or controller
Connecting a Interface Converter Unit To connect the VP-43xl Interface Converter unit, do the following1: Connect a DB 9 flat-cable to the RS-232 in port, if control via a PC is required (for example, when using the Kramer Control software or other controller), as section 5.1 describes Connect a DB 9 flat-cable to the RS-232 out port, if required Connect a RS-485 terminal block connector cable if control via RS -485 is required, as section 5.2 describes Connect a DB 9 flat-cable to the RS-422 port, if control via RS-422 is required, as section 5.4 describes Set the SETUP dipswitches as section 5.5 describes Connect the supplied 12V DC power adapter to the power socket and connect the adapter to the mains electricity
1 Switch OFF the power on each device before connecting it to your VP -43xl Interface Converter unit. After connecting your VP-43xl Interface Converter unit, switch on its power and then switch on the power on each device
4
KRAMER ELECTRONICS, LTD.
Page 7
Connecting a Interface Converter Unit
5.1 Connecting a PC (RS-232) To connect a PC to the VP-43xl Interface Converter unit, do not use a Null-modem adapter. Do one of the following: For a 9 pin COM port (DB9): Connect the RS -232 port on your PC to the RS-232 in DB9F port on the VP-43xl Interface Converter unit, with a one-to-one flat-cable connection; or For a 25 pin COM port (DB25): Connect the RS -232 port on your PC to the RS-232 in DB9F port on the VP-43xl Interface Converter unit, as Figure 3 illustrates
Figure 3: Connecting a PC without using a Null-modem Adapter
5.2 Connecting the RS-485 Connector Figure 4 defines the RS-485 connector PINOUT for RS-485 control:
Figure 4: RS-485 Connector PINOUT
To connect the VP-43xl unit’s RS-485 connector, do the following: 1.
Connect the “A” (+) PIN on the first VP-43xl Interface Converter unit to the “A” (+) PIN on another VP-43xl Interface Converter unit1 or on a switcher or controller 2
1 As Figure 9 and Figure 10 illustrate 2 As Figure 13 and Figure 14 illustrate
5
Page 8
Connecting a Interface Converter Unit
2.
Connect the “B” (-) PIN on the first VP-43xl Interface Converter unit to the “B” (-) PIN on the other VP-43xl Interface Converter unit or on a switcher or controller
3.
Connect the “G” (Ground) PIN to the shield if using a shielded cable.
5.3 Understanding the RS-422 Connector Sections 5.3.1 to 5.3.6 describe RS-422 functionality. 5.3.1
Signal Terminology
Connections are between Master and Slave or Controller and Controlled devices, rather than the regular In and Out or Source and Destination devices. The difference is not merely one of semantics but a vital distinction when trying to understand the concept of RS-422 technology With a regular In and Out switcher, not only does the front panel have separate In and Out buttons but the rear panel also has separate ports for input and output connectors With a Master and Slave control switcher, the front panel has separate Master and Slave buttons but the rear panel has shared Master / Slave connectors 5.3.2
Bi-directional Signals
By using a pair of conductors, each signal travels in both directions via a balanced line between Master / Slave devices, as Figure 5 illustrates:
Figure 5: Bi-directional Signals I
When a Master device changes position with a Slav e device, the pins change, as Figure 6 illustrates:
Figure 6: Bi-directional Signals II
5.3.3
Set DIP 8, as Table 3 defines, to assign PINS 2 and 7 and PINS 3 and 8 Communication Method via a DB9 Connector
The Master unit usually sends a command to the Slave device via pins 3(+) and 8(-) and the Slave device responds to the Master via pins 2( -) and 7(+) 6
KRAMER ELECTRONICS, LTD.
Page 9
Connecting a Interface Converter Unit
Keep the communication path clear between the Master and Slave units in both directions, as the Slave device must respond to a command transmitted by the Master If the Master receives no response from the Slave, the Master may cancel the communication with the Slave machine and will sometimes flag a message: no communication. For example, in video production when a special controller (with play and rewind functionality) is the Master device, each command transmitted to the Slave device must reach that Slave device and that Slave device must respond, otherwise the Master device will disconnect the communication 5.3.4
Device Definition
In many broadcast applications, different machines involved in production can be either Slaves or Masters. Using a device as a Master means that the device transmits via pins 3 and 8 and receives via pins 2 and 7. In some other setup that uses the same device as a Slave, this will mean that the device transmits via pins 2 and 7 and receives via pins 3 and 8 For example, an edit controller always works as a Master. During an editing session, a VTR may be the Slave to the edit controller. However, in a duplication setup, the VTR may become a Master for a second VTR. Configure the VP-43xl Interface Converter, as a Slave, by setting DIP 8 OFF. Configure the VP-43xl Interface Converter as a Master, by setting DIP 8 ON 5.3.5
Port Definitions
Modern equipment usually has only one connector, RS -422, which functions as a Master as well as a Slave Some older broadcast equipment contains 3 RS-422 connectors; RS-422-In, RS-422-Out and RS-422-In/Out. You can only connect a Master to an RS-422-In port and you can only connect an RS-422-Out port to a Slave. When connecting to an RS-422-In/Out port1 the unit changes dynamically, automatically reconfiguring the DB9 port pins to be either a Master or a Slave 5.3.6
More Than One Slave
Communication between one Master and one Slave is simple. However, communication between one Master and several Slaves, for example, in duplication applications, is more complicated, as Figure 7 illustrates.
1 Item 1 in Table 2
7