The text of a manual · part 9 of 15
N-400 User's Manual: Multi-Drop Controller for BL Series, pages 81 to 90
Pages 81 to 90 of 150
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence N-400
Page 81
Chapter 4
Multi-Drop Link Mode Control Procedure
•
The “LON” command corresponds to “Trigger input: ON”, and the “LOFF” command corresponds to “Trigger input: OFF”.
•
When the bar code data read by the BL series has already been sent to the host computer, you do not need to send the “LOFF” command (in “Single Label” reading mode only).
•
These commands can be changed to any string of up to eight characters.
Reset Resets the data stored in the N-400. Command: RESET Response: OK
Clearing transmission buffer Clears the transmission buffer of the N-400 and all BL series. Command: BCLR Response: OK
4
Checking trigger input status Used to monitor the ON/OFF status of the trigger input connected to the N-400. * This command can be used in multi-head scan mode only. Command: TIMCHK Response: ON OFF
Shift to SETUP mode Used to go to the SETUP mode. (See p. 4-19.) Command: SSET Response: OK
Specifying the ID number of command transmission destination (Hotline command) Normally, when a command is sent to the BL series, the ID number of the BL series is added to the command. If you send the following command, you can send a command to the specified BL series without adding its ID number to the command. After using this command, be sure to reset it. ● Specifying the Destination ID number for command transmission Command: TRCIMmm [mm = 01 to 31 (ID number)] Response: OK ERR01: “mm” exceeds the range of “01” to “31”. ● Resetting the destination ID number for command transmission Command: TROFF Response: OK
73
Page 82
Chapter 4
Multi-Drop Link Mode Control Procedure ● Checking the destination ID number for command transmission Command: TRCOM Response: mm [mm = 01 to 31 (ID number) mm = 00: ID number is not specified.] ■ Description of the procedure 1. Send the “TRCOMmm” command. (The N-400 sends back “OK”.) The N-400 displays the specified ID number. 2. You can then send a command to the specified BL series without adding its ID number. (For the commands sent to the BL series, see the BL series User’s Manual.)
Example • To start reading: Send “LON [CR]”. • To end reading: Send “LOFF [CR]”. • To go to the SETUP mode: Send “SSET [CR]”.
4
3. When the N-400 fails to send a command to the BL series, the BL series sends back the following response: NC: The BL series with the specified ID number is disconnected. SERR: Communication error 4. After the command transmission is completed, be sure to send “TROFF”. Otherwise, the N-400 cannot receive any commands.
74
Page 83
Chapter 4
4.5
Multi-Drop Link Mode Control Procedure
N-400 Setup Command This section describes the procedure for changing the N-400’s settings by sending a command to the N-400. To change the settings of the N-400, you should normally use the N-400 setup software instead of these commands. ■ Details of the communication 1. Send the “SSET” direct control command to the N-400. The N-400 then goes into SETUP mode. (In SETUP mode, the N-400 displays “S1(51)”.) When this command is processed normally, the N-400 sends back “OK”. 2. After the N-400 goes into SETUP mode, send the command of the item to be changed (setting change command) to the N-400. When this command is processed normally, the N-400 sends back “OK”. If an error occurs, the N-400 sends back “ERR**”. (** is the error code.) 3. To confirm the N-400’s current settings, send the setting check command to the N-400. When this command is processed normally, the N-400 sends back the data on the current settings. If an error occurs, the N-400 sends back “ERR**”.(** is the error code.) 4. To save the settings in the EEPROM of the N-400, send the “SAVE” command to the N-400. If updated settings are saved in the EEPROM, these settings take effect the next time the N-400 is turned ON. When this command is processed normally, the N-400 sends back “OK”. If an error occurs, the N-400 sends back “ERR**”. (** is the error code.) 5. To exit SETUP mode and perform normal reading operation, send the “SEND” command to the N-400. When this command is processed normally, the N-400 sends back “OK”. If an error occurs, the N-400 sends back “ERR**”. (** is the error code.) ■ Communication format The ID number is not specified in the command/response format. The N-400 returns the response with the same header and delimieter as it receives. When the command format is [Command][CR], the response format is [Response][CR]. When the command format is [STX][Command][ETX], the response format is [STX][Response][ETX]. Command
Response
Command CR
Response CR
STX Command ETX
STX Response ETX
*
[LF] can be added to the end of the command. However, [LF] is not added to the response.
*
When [ESC] is added to the head of the command, the N-400’s receiving buffer is cleared. However, [ESC] is not added to the response.
75
4
Page 84
Chapter 4
Multi-Drop Link Mode Control Procedure ■ Response error codes If an incorrect setup command is sent to the N-400, the N-400 sends back the cause of the error (error code). Error response: ERR** (** is the error code.)
Error code
4
76
Cause of error
00
Undefined command
01
The ID number exceeds the setting range.
02
The number included in the command does not correspond to anything.
05
The number included in the command is too long.
06
“hhh...” is too short.
07
“N” is any value other than “0” or “1”.
08
“n” exceeds the setting range.
09
“nnn” or “nn” exceeds the setting range.
10
“hhh...” is not specified as HEX codes (hexadecimal numbers).
11
Setting “hhh... = FF” is impossible.
12
“hhh...” exceeds the specified number of characters.
14
The data stored in the EEPROM may be corrupted. Initialize the settings.
15
The area storing the initial settings is incorrect.
Page 85
Chapter 4
Multi-Drop Link Mode Control Procedure
Description of setup commands ■ Saving settings/Initializing settings/Quitting SETUP mode Function
Command
Response
Description
Error code
Saving settings in the EEPROM
SAVE
OK
See p. 74.
00, 02, 05, 14
Initializing settings
DFLT
OK
Resets the current settings to the default values and saves them in the EEPROM.
00, 02, 05, 14, 15
Quitting SETUP mode
SEND
OK
See p. 74.
00, 02, 05, 14
Response Description
Error code
■ HOST MODE Function
Command
Mode
Change
WP00n
OK
Confirm
RP00
00n
Interference suppression Trigger
Change
WP06n
OK
Confirm
RP06
06n
ON time in interference suppression mode
Change
WP47nnn
OK
Confirm
RP47
47nnn
Read mode
Change
WP12n
OK
Confirm
RP12
12n
WP13n
OK
RP13
13n
Data transChange mission timing (Effective in signal label Confirm mode only) Read error code
Tips
Change
WP55hhh.. OK
Confirm
RP55
55hhh..
n = 0: Multi-drop link n = 1: Multi-head scan mode n = 0: Disable n = 1: Enable
00, 02, 05, 07, 14 nnn = 001 to 255 (Units: 10 ms)
00, 02, 05, 07, 09, 14 n = 0: Single n = 1: Multi-label 1 n = 2: Multi-label 2
00, 02, 05, 08, 14 n = 0: After read n = 1: At trigger
00, 02, 05, 07, 14
4 hhh... = Read error code 00, 02, (up to eight characters) 05, 10, * To set a read error code, 12, 14 use HEX (hexadecimal) codes. * hhh... = FF: Read error code is not set.
To set a read error code, use the following command format.
Example: To set the read error code to “BR” B R WP554252
* B = 42h, R = 52h
77
Page 86
Chapter 4
Multi-Drop Link Mode Control Procedure ■ TRIGGER INPUT SETUP (Effective in multi-head scan mode only) Function
Command
Trigger input signal type
Change
One-shot input time Trigger input time
OK
Confirm
RP05
05n
Change
WP42nnn
OK n = 0: Level n = 1: One-shot nnn = 001 to 255 (Units: 100 ms)
Confirm
RP42
42nnn
Change
WP04n
OK
RP04
04n
Change
WP03n
OK
Confirm
RP03
03n
Characters of trigger ON command
WP56hhh...
OK hhh... =
Change
Confirm
RP56
Characters of trigger OFF command
Change
WP57hhh.. OK n = 0: 2 ms n = 1: 10 ms
Error code 00, 02, 05, 07, 14 00, 02, 05, 07, 09, 14 00, 02, 05, 07, 14 n = 0: Normally open n = 1: Normally closed
Confirm
Tips
WP05n
Confirm
State of trigger input
4
Response Description
57hhh..
56hhh...
Trigger ON command (up to eight characters) * To set this command, use HEX (hexadecimal) codes. hhh... = Trigger OFF command (up to eight characters) * To set this command, use HEX (hexadecimal) codes.
00, 02, 05, 06, 11, 14
00, 02, 05, 06, 11, 14
To set the characters of the trigger ON/OFF commands, use the following command format:
Example: To change the trigger ON command to “[CR]” or “[STX]S[ETX]”. S WP5653
78
* S = 53h
Page 87
Chapter 4
Multi-Drop Link Mode Control Procedure
■ PROTOCOL SETUP Function
Command
Handshaking protocol 1
Change
WP07n
OK
Confirm
RP07
07n
*To set details of the protocol, use handshaking protocol 2.
Change
WP08n
OK n = 0: PASS/RTRY protocol
Confirm
RP08
08n n = 1: ACK/NAK protocol
Change
WP51hhh...
OK hhh... = Header (up to five characters) * To set a header, use HEX (hexadecimal) codes. * hhh... = FF: Header is not set. hhh... = Delimiter (up to five characters) * To set a delimiter, use HEX (hexadecimal) codes. * hhh... = FF: Delimiter is not set.
Handshaking protocol 2
Header
Delimiter
Adding checksum
Response Description
Confirm
RP51
51hhh...
Change
WP52hhh...
OK
Confirm
R39
39n
Change
WP39n
OK
Confirm
RP39
39n
Error code n = 0: No handshaking n = 1: Use protocol 00, 02, 05, 07, 14
00, 02, 05, 10, 12, 14
4 00, 02, 05, 07, 14 n = 0: Do not add n = 1: Add
79
Page 88
Chapter 4
Multi-Drop Link Mode Control Procedure ■ PROTOCOL SETUP (only when PLC link is used) Function
Command
PLC link model
Change
Response Description WP36n
OK n = 0: PLC link disabled n = 1: SYSNAC-C n = 2: MELSEC-A
Confirm
RP36
36n
Error code n = 3: KV
00, 02, 05, 08, 14 n = 4: MELSEC-A (File register is used.) Change Confirm
RP37
37n
DM head address
Change
WP40nn
OK
Confirm
RP40
40nn
Change
WP43nn
OK
Confirm
RP43
43nn
Change
WP41nnn
OK
Confirm
RP41
41nnn
PLC / station number
4 File register block number
80
OK
Trigger input through PLC link
WP37n n = 0: Disable n = 1: Enable
00, 02, 05, 07, 14 nn = 00 to 99 (0000 to 9900) nn = 00 to 31 nnn = 000 to 255
00, 02, 05, 07, 09, 14
Page 89
Chapter 4
Multi-Drop Link Mode Control Procedure
■ ID SETUP Function
Command
Response
Description
Registering ID number (for each unit)
Change WIDmmn
OK mm = 01 to 31 (ID 3 number)
Confirm RIDmm mmn n = 0: Do not register n = 1: Register
Change
Confirm
RWIDMAXmm MAXmm
* If “mm” is “99” in the response, serial ID numbers are not registered.
Registering all serial numbers
Change
WIDAnnn...n OK n = 0: Do not register n = 1: Register
Confirm
RIDA
Annn...n
00, 01, 02, 05, 07, 14 mm = 01 to 31 (ID 4 number)
Registering serial numbers (Register all ID numbers more than the specified number.)
WIDMAXmm OK
Error code
* “n” corresponds to ID numbers (1 to 31) in ascending order.
00, 01, 02, 05, 14
00, 02, 05, 07, 14
■ RS-232C SETUP Function
Command
Response Description
Baud rate
Change
OK
WP35n n = 5: 38400 bps n = 6: 31250 bps n = 7: 19200 bps n = 0: 9600 bps
Confirm
RP35
35n
Error code 00, 02, 05, 08, 14 n = 1: 4800 bps n = 2: 2400 bps n = 3: 1200 bps n = 4: 600 bps
Data length
Parity
Parity type
Stop bit length
RTS/CTS control
Change
WP30n
OK
Confirm
RP30
30n
Change
WP31n
OK n = 0: None n = 0: 7 bits n = 1: 8 bits
Confirm
RP31
31n n = 1: Set parity * To set the parity type, use the "Parity type" command.
Change
WP32n
OK n = 0: Even
Confirm
RP32
32n
Change
WP33n
OK
Confirm
RP33
33n
Change
WP22n
OK
Confirm
RP322
22n n = 1: Odd
00, 02, 05, 07, 14 n = 0: 1 bit n = 1: 2 bits n = 0: Disable n = 1: Enable
81
4
Page 90
Chapter 4
Multi-Drop Link Mode Control Procedure ■ RS-485 SETUP Function
Command
Response Description
Baud rate
Change
OK
WP75n
Error code n = 5: 38400 bps n = 6: 31250 bps n = 7: 19200 bps n = 0: 9600 bps
Confirm
RP75
75n n = 1: 4800 bps
00, 02, 05, 08, 14 n = 2: 2400 bps n = 3: 1200 bps n = 4: 600 bps Data length
Parity
4
Parity type
Stop bit length
82
Change
WP70n
OK
Confirm
RP70
70n
Change
WP71n
OK n = 0: None n = 1: Set parity * To set the parity type, use the "Parity type" command.
Confirm
RP71
71n
Change
WP72n
OK
Confirm
RP72
72n
Change
WP73n
OK
Confirm
RP73
73n n = 0: 7 bits n = 1: 8 bits n = 0: Even n = 1: Odd n = 0: 1 bit n = 1: 2 bits
00, 02, 05, 07, 14