Page 141
Appendices
Indications on the N-400 The N-400 displays the following codes: ■ Status indication These codes indicate that the N-400 is in a special condition. S0 (50): When you press and hold the test switch for five seconds, this code is displayed. When the N-400 displays this code, the communication parameters are set as follows: (➮ See p. 48.) This code is used to send settings to the N-400 on the N-400 setup software. Baud rate: 9600 bps Data length: 7 bits Parity: Even Stop bit length: 1 bit Using PLC link: Disable S1(51): The code indicates that the N-400 is in SETUP mode. This code is displayed after the SSET command is sent, or while settings are sent to the N-400 or received from the N-400 on the setup software. ■ Error indication The following codes indicate that the N-400 is in an abnormal condition. “99”: 99 That the N-400 is defective. If this error cannot be removed even when the test switch is pressed, contact KEYENCE. “98”: 98 Indicates an EEPROM memory error. All the settings will be initialized. Press the test switch to reset this error. “97”: 97 Indicates a data overflow in the N-400’s buffer. Press the test switch to reset this error. “96”, ”95”: 96 95 Displayed when communication is abnormal in PLC link mode. (Indicates a PLC link error.) Press the test switch to reset this error.
133
Appendices
Appendix E
Page 142
Appendices
Appendix F
ASCII Code Table
High-order 4 bits Hexadecimal
0
1
2
3
4
5
6
7
Appendices
Low-order 4 bits
Binary 0000 0001 0010 0011 0100 0101 0110 0111
134
0
0000
DLE (SP)
0
@
P
' p
1
0001 SOH DC1
!
1
A
Q a q
2
0010 STX DC2
”
2
B
R b r
3
0011 ETX DC3
#
3
C
S c s
4
0100 EOT NAK
$
4
D
T d t
5
0101 ENQ DC4
%
5
E
U e u
6
0110 ACK SYN
&
6
F
V f v
7
0111 BEL ETB
’
7
G
W g w
8
1000 BS CAN
(
8
H
X h x
9
1001 HT
EM
)
9
I
Y i y
A
1010 LF
SUB
✽
:
J
Z j z
B
1011 HM ESC
+
;
K
[ k
{
C
1100 CL
,
<
L
\
I
D
1101 CR
–
=
M
]
M
}
E
1110 SO
.
>
N n
~
F
1111 SI
/
?
O o del
_
Page 143
Appendices
Checksum Calculation Method You can add a checksum to transmitted data. (The checksum cannot be added to a command or a response to a command.) Adding a checksum enables incorrect data translation to be detected in the RS232C communication. If the checksum does not match when the PASS/RTRY or ACK/NAK protocol is used, modify the program so that the “Request to resend” (RTRY or NAK) command is sent to the N-400. To set the checksum, use the “PROTOCOL SETUP” screen of the N-400 setup software. (The checksum cannot be added when the PLC link is used.) ■ Checksum calculation range and the position to add checksum The checksum calculation is performed with all characters except for the header and delimiter. The checksum is added immediately before the delimiter. CC = Checksum (Two ASCII code characters) •
Data communication in multi-drop link mode Header % P mm – Read Data CC Delimiter Calculation range Result
•
Data communication in multi-head mode Header Read Data CC Delimeter Calculation range Result
■ Checksum calculation method Example:
Appendices
Appendix G
Header % P 01 – AB12 CC Delimiter
Calculate the checksum (CC) in the above example. Convert each character into the ASCII code as shown below, and express the result as 8-bit binary numbers. Calculate the “Exclusive-OR” of the binary numbers of each bit. Data % P 0 1 – A B 1 2
ASCII code (Hexadecimal) 25h 50h 30h 31h 2Dh 41h 42h 31h 32h
* Based on the “Exclusive OR” logic, when an odd number of “1”s are present, the calculation result is “1”, and when an even number of “1”s are present, the calculation result is “0”.
Binary
0010 0101 0011 0011 0010 0100 0100 0011 0011
0101 0000 0000 0001 1101 0001 0010 0001 0010
+
0101
1001
59h
135
Page 144
Appendices Convert the calculated hexadecimal number into an ASCII code in two digits. The result obtained is the checksum. Therefore, the checksum for the above example is “cc = 59 (35h 39h). Example: Result: CC=04
Header % P 15 – ERROR CC Delimiter
CC=04
Header 1234 CC Delimiter
Tips
•
* •
Exclusive OR calculation formula Calculate the numbers of each bit, referring to the following formula: 0+0=0 0+1=1 1+0=1 1+1=0 + : Operator of Exclusive OR Conversion from hexadecimal number into binary number To convert ASCII codes into binary numbers, refer to the following table. Hexadecimal number Binary number Hexadecimal number
Appendices
Binary number
136
0
1
2
3
4
5
6
7
0000 0001 0010 0011 0100 0101 0110 0111 8
9
A
B
C
D
E
F
1000 1001 1010 1011 1100 1101 1110 1111
Page 145
Appendices
Appendix H
Setup Parameter List
HOST MODE Mode
❑ Multi-drop link mode ❑ Multi-head mode Interference suppression
❑ Disable ❑ Enable
Trigger ON time for interference suppression
( ) * 10 ms to 2550 ms
Reading mode
❑ Single label ❑ Multi label 1 ❑ Multi label 2 ❑ After reading ❑ At trigger OFF
Data-send timing Read error code
(
)
* Up to eight characters
TRIGGER SETUP (Effective in multi-head mode only) Trigger input signal type
❑ Level
One-shot input time
(
❑ One-shot
Input time State
❑ 2 ms ❑ Normally-open
Trigger ON command
(
)
* Up to eight characters
Trigger OFF command
(
)
* Up to eight characters
)
* 100 ms to 25.5 s
❑ 10 ms ❑ Normally-closed
PLC link
❑ Disable Handshaking
PLC trigger area
❑ No handshaking ❑ PASS/RTRY ❑ ACK/NAK ❑ None ❑ STX ❑ ESC ❑ Custom ( ) * Up to five characters ❑ CR ❑ CR + LF ❑ ETX ❑ Custom ( ) * Up to five characters ❑ Do not add ❑ Add ❑ Do not add ❑ Add ❑ SYSMAC-C ❑ MELSEC-A ❑ KV ❑ Disable ❑ Enable
DM head address
(
) 00
* 0000 to 9900
PLC station/ unit number
(
)
* 000 to 255
Header Delimiter Add ID Checksum
❑ Enable
PLC model name
File register
❑ Disable
File register block number
(
❑ Enable )
* 000 to 255
137
Appendices
PROTOCOL SETUP
Page 146
Appendices
ID SETUP ❑ 01 ❑ 02 ❑ 03 ❑ 04 ❑ 05 ❑ 06 ❑ 07
❑ 08 ❑ 09 ❑ 10 ❑ 11 ❑ 12 ❑ 13
❑ 14 ❑ 15 ❑ 16 ❑ 17 ❑ 18 ❑ 19
❑ 20 ❑ 21 ❑ 22 ❑ 23 ❑ 24 ❑ 25
❑ 26 ❑ 27 ❑ 28 ❑ 29 ❑ 30 ❑ 31
RS-232C SETUP Baud rate
(
Data length
RTS/CTS handshaking
❑ 7 bits ❑ Even ❑ 1 bit ❑ Disable
Baud rate
(
Data length
❑ 7 bits ❑ Even ❑ 1 bit
Parity Stop bit length
)
❑ 8 bits ❑ Odd ❑ 2 bits ❑ Enable
* 600 to 38400 bps
❑ None
RS-485 SETUP
Parity
Appendices
Stop bit length
138
)
❑ 8 bits ❑ Odd ❑ 2 bits
* 600 to 38400 bps
❑ None
Page 147
Appendices
Appendix I
Default Setting List
HOST MODE Mode
Multi-drop link
PLC link
Disable
Handshaking
No handshaking
Header
None
Delimiter
CR
Add ID
Add
Checksum
Do not add
PROTOCOL SETUP
ID SETUP Only ID 1 is registered.
Baud rate
9600
Data length
7 bits
Parity
Even
Stop bit length
1 bit
RTS/CTS handshaking
Disable
Baud rate
9600
Data length
7 bits
Parity
Even
Stop bit length
1 bit
Appendices
RS-232C SETUP
RS-485 SETUP
139
Page 148
Appendices
Appendix J
Sample Printout of Setting List / / / New setting data [Untitled] / / / [X] selected [X] - - - - - => Changed 1) HOST MODE [MODE] [Interference Suppression] [Read mode] [Data-send] [Read error code]
[X] MULTI-DROP LINK [X] MULTI-HEAD SCAN [X] Disable [X] ENABLE Timer [10] x 10 msec [X] Single [X] Multi 1 [X] Multi 2 [X] After read [X] At trigger input ERROR [4552524F52]
2) Trigger setup (only with MULTI-HEAD SCAN) [Signal type] [X] Level [X] One-shot [One-shot input time] [10] x 100 ms [Input time] [X] 2 ms [X] 10 ms [State] [X] Normally-open [Command for Trigger ON] LON [4C4F4E] [Command for Trigger OFF] LOFF [4C4F4646]
Appendices
3) PROTOCOL SETUP [Use PLC] [Handshaking] [Header] [Delimiter] [Add ID] [Checksum] [PLC Model Name] [PLC Trigger Area] [DM Head Address] [PLC Station/Unit No.] [File Register] [File Register Block Number]
[X] Normally-close
[X] Don't use [X] Use [X] No handshaking [X] PASS/RTRY [X] ACK/NAK [X] None [X] STX [X] ESC [X] Custom [X] CR [X] CR + LF [X] ETX [X] Custom [X] Don’t Add [X] Add [X] Don’t Add [X] Add [X] SYSMAC-C [X] MELSEC-A [X] KV [X] Disable [X] ENABLE 000 0 [X] Disable [X] ENABLE 0
4) ID setup [X]01 [X]02 [X]03 [X]04 [X]05 [X]06 [X]07 [X]08 [X]09 [X]10 [X]11 [X]12 [X]13 [X]14 [X]15 [X]16 [X]17 [X]18 [X]19 [X]20 [X]21 [X]22 [X]23 [X]24 [X]25 [X]26 [X]27 [X]28 [X]29 [X]30 [X]31
140
5) RS-232C [Baud rate] [Data bits] [Parity] [Stop bits] [RTS / CTS]
9600 bit/s [X] 7 bits [X] 8 bits [X] Even [X]Odd [X]None [X] 1 bit [X]2 bits [X] Invalid [X]Use RTS / CTS handshaking
6) RS485 [Baud rate] [Data bits] [Parity] [Stop bits]
9600 bit/s [X] 7 bits [X] 8 bits [X] Even [X]Odd [X] 1 bit [X]2 bits
[X]None
Page 149
WARRANTIES AND DISCLAIMERS: (1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples. Any Products found to be defective must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any action of Buyer, including but not limited to improper installation, improper interfacing, improper repair, unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Components which wear are not warranted. (2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are only suggestions, and it is Buyer’s responsibility to ascertain the fitness of the Products for Buyer’s intended use. KEYENCE will not be responsible for any damages that may result from the use of the Products. (3) The Products and any samples (“Products/Samples”) supplied to Buyer are not to be used internally in humans, for human transportation, as safety devices or fail-safe systems, unless their written specifications state otherwise. Should any Products/Samples be used in such a manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage whatsoever arising out of any misuse of the Products/Samples. (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply. BUYER’S TRANSFER OBLIGATIONS: If the Products/Samples purchased by Buyer are to be resold or delivered to a third party, Buyer must provide such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written information provided to Buyer pertaining to the Products/Samples.
141
Page 150
N-400 User's Manual
96M0353
User's Manual Multi-Drop Controller for BL Series
N-400
N-400 TEST
RS-232C
READER
SD
RD
POWER TIMING
POWER
SD
RD
TERMINATOR
OFF
TERMINATOR ON OFF
Specifications are subject to change without notice. AFFILIATED COMPANIES
KEYENCE CORPORATION 1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan Phone: 81-6-6379-2211 Fax: 81-6-6379-2131
KEYENCE CORPORATION OF AMERICA Phone: 201-930-0100 Fax: 201-930-0099
KEYENCE ITALIA S.p.A. Phone: 02-6688220 Fax: 02-66825099
KEYENCE TAIWAN CO., LTD Phone: 02-2627-3100 Fax: 02-2798-8925
KEYENCE DEUTSCHLAND GmbH Phone: 06102-36 89-0 Fax: 06102-36 89-10 0
KEYENCE SINGAPORE PTE LTD Phone: 6392-1011 Fax: 6392-5055
KEYENCE (HONG KONG) CO., LTD Phone: 3104-1010 Fax: 3104-1080
KEYENCE (UK) LIMITED Phone: 01908-696900 Fax: 01908-696777
KEYENCE (MALAYSIA) SDN BHD Phone: 03-2092-2211 Fax: 03-2092-2131
KEYENCE FRANCE S.A. Phone: 01 56 37 78 00 Fax: 01 56 37 78 0 1
KEYENCE (THAILAND) CO., LTD Phone: 02-369-2777 Fax: 02-369-2775
KEYENCE INTERNATIONAL TRADING (SHANGHAI) CO., LTD. Phone: 021-68757500 Fax: 021-68757550 KOREA KEYENCE CO., LTD. Phone: 02-563-1270 Fax: 02-563-127 1
© KEYENCE CORPORATION, 1997 0114-4 96M0353 Printed in Japan
RS
SD
RD RS-455
RS-232C
ON
CS