For the Keyence LV-H32
Page 1
Safety features
96M11626
„ Laser ON alarm indicator The laser ON alarm indicator will start flashing after power is turned on. The lamp will remain ON for as long as the laser light is emitting. This alarm indicator can be seen even when wearing protective goggles
General Purpose Digital Laser Sensor
.
LV Series
LASER ON MODE SET
Instruction Manual
PH
BH
%
Laser ON alarm indicator
A B
„ Laser emission stop input (LV-21A/21AP/51M/51MP/11A) Laser emission can be stopped by short-circuiting between the purple and blue (GND) wires when LV-21A, LV-51M or LV-11A used. When LV-21AP or 51MP is used, short-circuit between the purple and brown (12 to 24 V DC) wires to stop laser emission.
Main circuit
5 V DC
Purple
Blue (Short circuit current 1 mA max.)
LV-21A/11A/51M
„ Label location
Warning labels are attached to the sensor head, as shown below. • LV-H32
• LV-H37/H47 Protect housing label
Aperture
Safety Information for LV Series
•
Aperture
LV-H100 (Transmitter side)/ H110 (Transmitter side) Aperture label
Aperture label
Aperture label
WARNING
• This product is just intended to detect the object(s). Do not use this product for the purpose to protect a human body or a part of human body. • This product is not intended for use as explosion-proof product. Do not use this product in a hazardous location and/ or potentially explosive atmosphere. • LV-H35F/H62F uses glass parts. Since there is the possibility of breakage in the case of dropping etc, take adequate care when handling. When pressure is placed on the glass portion (the main unit detection part, the reflective surface of the reflector), the waterproofing of the product may be damaged so please take great care.
TH WI S 1 LIE 0.1 MP 104 CO D T N UC 0 AN M. nm IO OD 0.1 UTIO ION O BEA 660 3mW s PR 104 CA IAT INT ER IS R 3.5 TH CF RAD RE R LAS 21 ER STA CTO T
TH WI S 1 LIE 0.1 MP 104 CO D T . N UC 0 AN nm AM IO OD 0.1 UTIO N- O BE 660 3mW s PR 104 CA DIATIO INT ER IS R 3.5 TH CF RA RE R LAS 21 ER T STA CTO T T
Aperture
PUT LAS NOT NDU DUC N DO ICO M OUTATIO PRO SEM IMU DUR ER AX SE II LAS PUL SS CLA
LAS NO NDU TPU N DUC OU DO ICO PRO UM ATIO SEM XIM DUR ER MA SE II LAS PUL SS CLA
WITH S LIE .11 MP 1040 CO T AND . UC AM 0nm ON OD .10 66 W N- O BE UTI 3m s PR 1040 CA DIATIOE INT SER IS R 3.5 TH CF RA R LA R OR 21 T SE T ST CT UT
Laser CLASS II warning label
UC LA NO DU TP ON OU TION PROD DO MIC UM R SE XIM DURA SE MA LSE II LA PU ASS CL
Laser CLASS II warning label
• LV-H42
• LV-H52
•
Aperture label
Aperture
LV-H300 (Transmitter side) Aperture label
Aperture label
Safety precautions on laser product
Aperture
WARNING
• Use of controls or adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure. • The LV series product uses a laser diode as a light source.
TH WI S 1 LIE 0.1 MP 104 CO D T N UC 0 AN M. nm IO OD 0.1 UTIO ION O BEA 660 3mW s PR 104 CA IAT INT ER IS R 3.5 TH CF RAD RE R LAS 21 ER STA CTO T
H WIT S 1 LIE 0.1 MP 104 CO D T UC 0 AN M. nm ION OD 0.1 UTIO ON O BEA 660 3mW s PR 104 CA IATI INT ER IS R 3.5 TH CF RAD RE R LAS 21 ER STA CTO T
PUT LAS NOT NDU DUC N DO ICO M OUTATIO PRO SEM IMU DUR ER AX SE II LAS PUL SS CLA
PUT LAS NOT NDU DUC N DO ICO M OUTATIO PRO SEM IMU DUR ER MAX SE II LAS PUL SS CLA
Laser CLASS II warning label
Aperture
Specifications of the laser diode change depending on the model. Refer to the tables below. LV-H32, H35, H37, H42, H47, H52, H62, H64, H65, H67, H35F, H62F, H100, H110, H300
LV-H41, H51
Wavelength Laser class
660 nm Class II Laser Product
785 nm Class I Laser Product
Output Laser class
3.0 mW Class 2 Laser Product
2.5 mW Class 1 Laser Product
1.0 m
0.3 mW
Sensor head
FDA IEC
Output
WITH S LIE .11 MP 1040 CO T AND . N UC ION N- BEAM 660nm W OD .10 UTI O 3m s PR 1040 CA DIATIOE INT ER IS R 3.5 TH CF RA LAS R ST R R 21 T SE T CTO UT UC LA NO DU TP ON OU TION PROD DO MIC UM SE XIM DURA ER MA LSE II LAS PU ASS CL
Laser CLASS II warning label
• LV-H35/H62/H67
Aperture label
Aperture
Aperture
Aperture label
TH WI S 1 LIE 0.1 MP 104 CO D T N UC 0 AN M. nm IO OD 0.1 UTIO ION O BEA 660 3mW s PR 104 CA IAT INT ER IS R 3.5 TH CF RAD RE R LAS 21 ER STA CTO T
TH WI S 1 LIE 0.1 MP 104 CO D T N UC 0 AN M. nm IO OD 0.1 UTIO ION O BEA 660 3mW s PR 104 CA IAT INT ER IS R 3.5 TH CF RAD RE R LAS 21 ER STA CTO T
PUT LAS NOT NDU DUC N DO ICO M OUTATIO PRO SEM IMU DUR ER AX SE II LAS PUL SS CLA
PUT LAS NOT NDU DUC N DO ICO M OUTATIO PRO SEM IMU DUR ER MAX SE II LAS PUL SS CLA
„ Warning labels • IEC CLASS 2
• LV-H64/H65
Laser CLASS II warning label
• Laser CLASS II warning labels(FDA CLASS II) • LV-H35/H62/H67
Aperture label
• IEC (French) CLASS 2
The FDA warning label has already been stuck.
Aperture
LAS NO NDU TPU N DUC OU DO ICO PRO UM ATIO SEM XIM DUR ER MA SE II LAS PUL SS CLA
• Aperture label
Laser CLASS II warning label
AVOID EXPOSURE
„ Safety consideration
LASER RADIATION IS EMITTED FROM THIS APERTURE.
• Follow the instructions mentioned in this manual. Otherwise, injury to the human body (eyes and skin) may result. • Do not disassemble this product. Laser emission from this product is not automatically stopped when it is disassembled. Precautions on Class I/1 Laser Products • Do not stare into the direct or specularly reflected beam. Precautions on Class II/2 Laser Products WARNING • Do not stare into the direct or specularly reflected beam. • Be careful of the path of the laser beam. If there is a possibility that the operator may be exposed to the specular or diffuse reflections, block the beam by installing a protective enclosure. • Install this produ so that the path of the laser beam is not as the same height as that of human eye.
• Protective housing label • DIN Klasse 2
CAUTION
TH WI S 1 LIE 0.1 MP 104 CO D T . N UC 0 AN nm AM IO OD 0.1 UTIO N- O BE 660 3mW s PR 104 CA DIATIO INT ER IS R 3.5 TH CF RA RE R LAS 21 ER T STA CTO T T
LV-H32 only
LASER RADIATION WHEN OPEN. DO NOT STARE INTO BEAM.
.
1
LV Series-IM_E
Page 2
„ LV-H51/H52
Part Names
„ LV-H35/H62/H67
Amplifier Transmitter Bar LED Monitor The current value of received light intensity is displayed relative to the setting value, within the range -15% to +15%. 15%–
10%–
Light is steadily received
5%–
Setting -5%– value
Light is irregularly received
-10%–
Light is irregularly interrupted
-15%–
Light is steadily interrupted
Transmitter, Receiver
Detection is generally stable when the received light intensity is at least ±10% different to the setting value, which is represented by the center bar of the LED monitor.
Receiver
„ LV-H64/H65
The illustration shows an example of a received light intensity of +5%.
NOTICE
Received light intensity monitor • Displaying received light intensity • Displaying excess gain • Displaying the hold value Bar LED monitor Displaying excess gain
M
„ LV-H35F/H62F
Transmitter, Receiver MODE button • Switching displays • Switching channels • Displaying various settings
Transmitter, Receiver
„ LV-H100/H110 Transmitter side (T)
Calibration indicator
Receiver side (R)
SET button
S Set up sensitivity
MODE SET
Peak hold display indicator Bottom hold display indicator
PH
BH
Excess gain indicator
%
A B Laser ON alarm indicator
UP/DOWN button
Setting monitor • Displaying setting values Channel indicator • Displaying settings Output B indicator
Output button Output A indicator
Black cable
Gray cable
• Changing setting values • Selecting between various settings
Transmitter
Receiver
Red
Blue
„ V-H300 Transmitter side (T)
Receiver side (R)
Sensor head „ Bar LED monitor (sensor head) When A, which is closer to the amplifier, is ON, the monitor displays the excess gain of output A. When B is ON, the monitor displays the excess gain of output B.
Bar Graph LED monitor (Interlocked with amplifier)
Gray cable
Black cable
Red Transmitter
Light is steadily received Setting value Light is steadily interrupted
Receiver
Blue
+10% - The indicator turns on according to the difference between the received light intensity and the setting value. The current level of detection stability can be -10% - determined from this difference.
Slit for sensor head (Option for LV-H41/H42/H47/H51/H52) Use in accordance with the distance and target.
Display excess gain on Bar LED monitor
• Attaching the slit Attach the slit to the transmitter • Removing the slit Remove the slit by lifting up the pin on the slit with a screwdriver.
If detection becomes unstable (light cannot be "steadily received" or "steadily interrupted") due to a change in the surroundings or the target, or for any other reason, readjust the sensitivity.
• LV-H41/H42
• LV-H51/H52
„ LV-H32 Adjust the beam spot size by turning the focus ring. After completing the adjustment, fix by turning the focus lock screw.
Transmitter
Focus lock • LV-H47
Focus ring Receiver
„ LV-H37/H47 Transmitter
„ LV-H41/H42
Accessories Amplifier
Transmitter Receiver
Amplifier Receiver
LV Series-IM_E
2
Mounting bracket (LV-21A/21AP/51M/ 51MP/11A only)
End unit (LV-22A/22AP/52/52P only)
Page 3
„ LV-H62
Sensor head
Reflector
„ LV-H32 Plastic driver
Mounting bracket Mounting bracket main body Board nut M3 x 18 screw:2
Mounting bracket Mounting bracket main body Board nut M3 x 18 screw:2
„ LV-H64/H65 Reflector
Mounting bracket Mounting bracket main body Board nut M3 x 18 screw:2
„ LV-H35 Mounting bracket Mounting bracket main body Board nut M3 x 18 screw:2
„ LV-H67 Reflector
Mounting bracket Mounting bracket main body Board nut M3 x 18 screw:2
„ LV-H37 Magnifying glass
Mounting bracket Mounting bracket main body Board nut M3 x 18 screw:2
„ LV-H35F/H62F Reflector
Mounting bracket Mounting bracket main body Board nut M3 x 22 screw:2
„ LV-H41/H42 Slit (black, gray)
Mounting bracket Mounting bracket main body Board nut M3 x 18 screw:2
Supplied only with LV-H62F
„ LV-H100/H110 Transmitter side (T)
Receiver side (R)
„ LV-H47 Slit (black, gray)
Mounting bracket Mounting bracket main body Board nut M3 x 18 screw:2 Black cable
Gray cable
„ LV-H300 Transmitter side (T)
Receiver side (R)
„ LV-H51/H52 Slit
Black cable
Gray cable
Input/Output Circuit Diagram z LV-22A/52 5 to 40 V DC 5 to 40 V DC
Purple(Laser radiation interruption input)
(Control output B)
Load
5 to 40 V DC
5 V DC Main circuit
Pink(External tuning input)* Blue * LV-51M (monitor output) only is orange.
z Laser radiation interruption z Analog output circuit (Main unit only) diagram for monitor External tuning input circuit (LV-51M/51MP) Load (Control 5 to 40 V DC diagram output A) LV-21A/11A/51M White Black
Main circuit
Black Load (Control output A) White Load (Control output B)
12 to 24 V DC Overcurrent protection circuit
Overcurrent protection circuit
Main circuit
Brown
0 V DC
Purple or Pink
(Short circuit current 1 mA max.)
z LV-22A/52 12 to 24 V DC
Main circuit
Black Load (Control output A) White Load (Control output B)
Purple (Laser radiation interruption input) Pink* (External tuning input) Blue * LV-51MP (monitor output) only is orange.
0 V DC
Protection circuit
Orange Output for monitor (1 to 4 V) Blue 0V
Blue
LV-21A/11A/51M 12 to 24 V DC
12 to 24 V DC Overcurrent protection circuit
Overcurrent protection circuit
Main circuit
Brown
Brown Black (Control output A) White (Control output B)
Load
Load
Main circuit z LV-11A/21A/51M
Main circuit z LV-11A/21A/51M
Purple or Pink
(Short circuit current 2 mA max.)
3
LV Series-IM_E
Page 4
„ Mounting the transmission type
Mounting Amplifiers
1 Insert the two connectors into the amplifier unit and lock them with the lever. Insert the transmitter side connector (with gray cable) into the light gray lever side, and insert the receiver side connector (with black cable) into the dark gray lever side. Route the cable underneath the lever and close the dust cover.
„ Mounting and detaching amplifiers to and from the DIN rail mounting bracket Hook the claw on the rear of the amplifier onto the mounting bracket of the DIN rail, then hook the front claw on the bracket while pressing the amplifier forward. To detach the amplifier, unhook the front claw by simultaneously lifting and pushing the amplifier forward. Mounting
Detaching
Receiver side (black cable)
Side mounting
M PH
BH
%
A B
Transmitter side (gray cable)
To shorten the sensor head cable „ Mounting additional amplifiers The number of expansion units that can be mounted to the side of main unit (LV-11A/21A/51M) is as shown below. Up to 7
LV-22A, LV-52, AP-V42
Up to 14
FS-T2/M2/V12/V22/PS-T2/ES-M2
Point
When the cable length of the sensor head is changed, be sure to connect the amplifier to check that it operates correctly.
1 Push the upper tab of the connector in the direction of arrow (1) and open it in the direction of arrow (2) to remove the cables.
1 Remove the protective cover on the
(1)
side of the amplifier.
(2)
2 Mount expansion units one by one to the DIN rail.
3 Slide one expansion unit toward the main unit or other unit. Align the front claws of the units and push them together until you hear a click.
2 Cut the cables to the appropriate length, and manipulate the end
Remove the protective cover of the cables as shown in the figure below.
4 Secure the units together by pushing
• Twist the silver shielded wire about five times so it does not ravel, and bend it 90° to the side.
the end units (included with the expansion unit) from both sides. Align the claws. Main unit
Expansion units
90° Cable core
End unit. (incl. with expansion units)
10 mm min.
Shield wire
3 Insert the cable with the shield wire bent at 90°C, then bend the shield wire in the direction of the arrow along the groove. Match the color of the connector to the color of the shield wire. Up to 14 expansion units can be added.
Red
* The sticker on the right is included with the expansion unit. Attach this sticker near the amplifier. White
4 Close the connector, and lock it by pushing down the top.
„ Detaching amplifiers
1 Take off the end unit. 2 Slide the expansion units. Remove them one by one from the DIN rail. Important
• When connecting several amplifiers, always use a DIN rail and end unit. • Take care to turn the power off before connecting/ disconnecting amplifiers. • Do not remove the protective cover from the expansion connector of the outermost unit. • Do not detach multiple units from the DIN rail while they are still connected to each other. • If several units are connected, check that the ambient temperature is appropriate. “Specifications” (page 8).
5 Using nippers or a similar tool, trim the wires sticking out from the connectors.
Mounting the Sensor Head
Point
„ Mounting the reflection type
1 Insert the connector into the amplifier and lock it with the lever. Pass the cable underneath the lever and close the dust cover.
Do not install the connectors more than two times. If the installation exceeds twice, purchase OP-27934 separately. If "brk" appears on the amplifier even when using pliers to crimp the connector, press the cable (part A) between the metallic contacts with a thin tool such as a flathead screwdriver to crimp the cable more firmly. Metallic contact Cable
Part A
LV Series-IM_E
4
Metallic contact
Page 5
Sensitivity Adjustment
Differentiation Mode (page 6)
„ Two-point tuning
„ Setting sensitivity Quickly press S once, to set sensitivity to its maximum value. Perform fine-tuning adjustments using or , or refer to the details on hold display below.
1 With no target in place, press the S button lightly.
MODE SET PH
BH
%
„ Received light intensity monitor
A B
2 Put a target in place and press the
The received light intensity monitor displays the amount of differentiation. Use hold mode switching with hold display ON.
S button again lightly.
„ Output state
MODE SET PH
Received light intensity
BH
%
A B
Setting value
The setting value is adjusted to the midpoint of the difference in received light intensity when the target is absent and present.
UP edge
The setting value is displayed.
D.ON L.ON
„ Maximum sensitivity setting For the reflection type sensor, adjust the sensitivity without using target. For the transmission type sensor, adjust the sensitivity by using target.
1 According to the directions on the left, press the S button for 3 seconds or more.
No target
PH
BH
N.C. output N.O. output
Differentiation Mode Detection (UP/DOWN edge) Detects only sudden changes in received light intensity within a certain time interval. • UP edge detection : Output is turned ON when light intensity increases by more than the setting value within a fixed time interval. • DOWN edge detection: Output is turned ON when light intensity decreases by more than the setting value within a fixed time interval. To achieve stable detection in differentiation mode, changes in received light intensity resulting from the presence or absence of the target must be greater than the changes in received light intensity resulting from dust or vibration.
Reference
Time
Reflection type
DOWN edge
N.C. output N.O. output
MODE SET %
A B
2 Confirm that the calibration indicator
Transmission type
Fine Adjustment of Setting Values
(orange LED) and setting monitor (green LED) are flashing.
The values displayed on the calibration LED monitor can be changed by pressing (to increase sensitivity) or (to decrease sensitivity). This allows you to fine-tune your setting values.
MODE SET
Target is used. PH
BH
%
A B
3 Release the S button.
If you press the S button accidentally while performing a fine adjustment of your setting values, a sensitivity calibration will start automatically and prevent you from continuing your fine adjustment until the calibration is completed. If this happens, press the S button again to cancel the setting and start your fine adjustment again. The value may not change by 1 digit during fine-tuning adjustments. This is not a malfunction.
Point
„ Automatic tuning
1 Pass a target through the optical axis while pressing the S button.
2 Confirm that the calibration indicator (orange LED) and setting monitor (green LED) are flashing.
Selecting Display Modes
MODE SET PH
BH
%
A B
The display changes each time the M MODE button is pressed. The received light intensity/excess gain hold display appears only after peak/ bottom hold is selected in the hold mode.
3 Release the S button. MODE SET PH
Received light intensity
BH
%
Light intensity display
A B
MAX
Setting value MIN
The setting value is displayed.
M Press this button once.
The setting value is adjusted to the midpoint of the difference in received light intensity when the target is absent and present.
M Press this button once. PH
Excess gain old display
Time
If the setting does not work well, perform the two-point tuning. PH
„ Positioning tuning
BH
BH
%
Light intensity hold display
When hold display is selected
Display Peak or Bottom
%
PH
BH
%
Excess gain display(%)
1 With no target in place, press the S button lightly (orange LED lights up).
MODE SET
PH
BH
PH
%
A B
2 Place a target in the position where BH
%
Displays setting value.
A B
3 Press the S button for 3 seconds or z Received light intensity display more until the calibration indicator (orange LED) and setting monitor (green LED) are flashing.
Displays received light intensity.
z Excess gain display Shows the received light intensity as a percentage of the setting value (setting value = 100%). This display cannot be shown when the standard light intensity display is selected.
MODE SET PH
BH
%
A B
Setting value
M Press this button once.
z Setting value display
MODE SET PH
%
For more information about hold display, refer to "Mode Setting" (p. 6). You cannot select the excess gain display when the standard light intensity is set.
it should stop.
Received light intensity
BH
M Press this button once.
The setting value is adjusted to turn on the sensor when the target arrives at the place where it should stop.
Point
The displayed value for excess gain is 0 when the excess gain is less than 1%.
Time
5
LV Series-IM_E
Page 6
Mode Setting Light intensity hold display
If you press the M button for three seconds or more when either Each setting can be adjusted separately for channel A and channel B.
Reference
Received light intensity or is displayed, you can display the values of various settings.
When the M button is pressed for 3 seconds or more during mode setting, the display returns to the received light intensity display. 1. Initial display MODE SET PH
BH
*LV-51M/52/51MP/52P only
%
A B
Press
1-1. Setting the standard light intensity
M for three seconds or more.
MODE SET PH
2. Selecting power mode MODE SET PH
BH
Select a standard light intensity by using
%
MODE SET or
• FINE
PH
BH
%
.
BH
%
MODE SET PH
M once lightly.
PH
BH
1) 2)
Set to this mode when there is insufficient light.
%
A B
Be sure to adjust the sensitivity again after switching POWER mode.
3. Selecting detection method MODE SET PH
BH
Select a detection mode to use for MODE SET
• STANDARD 1
PH
BH
%
A B MODE SET
• STANDARD 2 Press
2) 5: Standard light intensity is set to 500. 10: Standard light intensity is set to 1000. 20: Standard light intensity is set to 2000. 30: Standard light intensity is set to 3000.
3. Switching detection mode:(Skipped during the standard light intensity setting is in progress.)
%
A B
M once lightly.
PH
BH
%
BH
%
A B MODE SET
• DIFFERENTIATION
PH
(UP edge detection)
A B MODE SET
• DIFFERENTIATION
PH
(DOWN edge detection)
BH
%
A B or
%
1) A: Displays the data in accordance with the received light intensity b: Displays the data in accordance with the interrupted light intensity
MODE SET
• SUPER
BH
A B
Set to this mode for regular detection work.
A B
.
MODE SET PH
Set to this mode for detecting high-speed targets.
A B
• TURBO or
When you select OFF and press M once lightly, the menu moves to 2.
for both outputs A and B )
Select a power mode to use for for both outputs A and B )
%
A B
Press
BH
A B
2. Switching power mode:( AB
1-1. Setting the standard light intensity:( AB
Press
.
M once lightly.
Set this mode for regular detection work.
Ex. When the standard light intensity is 500. b-5 A-5 Displays the received Displays the interrupted light intensity light intensity
State
Use this mode to increase hysteresis.
Receive all light
Detects the UP edge of received light change. Detect the DOWN edge received light change.
500
0
250
250
0
500
Interrupt half light
Differentiation Mode Detection (page 5) Interrupt all light 4. Selecting display shift MODE SET PH
BH
%
A B
4. Switching display shift By pressing S once, the received light intensity display will shift to a value of 0. Also, fine adjustments of display shift can be done using or . Received light intensity after shift
1-2. Registering the standard light intensity
MODE SET PH
Press
M once lightly.
BH
MODE SET PH
%
BH
Press the S button in the state that no target is set. When the SET indication flashes quickly, the setting is completed.
%
A B
A B
Amount of shift NOTE Setting values will also shift.
*To set the shift value to 0, press together. 5. Selecting hold mode
Press
M once lightly.
and 1-3. Changing the number of display digits
5. Hold mode switching
MODE SET
Select a hold mode to use for PH
BH or
1-3. Changing the number of display digits :( AB for both outputs A and B )
MODE SET
.
%
PH
• NO HOLD
A B
1-2. Registering the standard light intensity :( AB for both outputs A and B )
BH
%
A B
The last digit of digital display can be set to non-display.
MODE SET PH
BH
Display is not held
%
PH
A B
BH
Press
M once lightly.
• PEAK HOLD
Ex. When A-5 is selected in 1-1 MODE SET
Press
M once lightly.
PH
BH
Peak value is held on the display
%
A B
PH
To "2. Selecting power mode"
%
PH
A B
6. Selecting timer mode MODE SET PH
BH
PH
BH
PH
BH
%
MODE SET
M once lightly.
• OFF DELAY
PH
BH
%
A B
MODE SET
• ON DELAY or
.
PH
BH
%
A B
Set to this mode for regular detection work.
Point
When the standard light intensity is set, the detection mode is fixed to "Standard Detection 1"
Use for output OFF delay Use for output ON delay
MODE SET
Selecting no timer
• ONE SHOT
7. Timer setting MODE SET BH
PH
BH
Use for one-shot output
%
A B
7. Timer setting Set the timer for or
.
% MODE SET
MODE SET
A B
PH A B
M once lightly.
BH
%
PH
BH
%
A B
Min. 1 ms to max. 9999 ms
* It is possible to perform detection work while changing mode settings.
LV Series-IM_E
%
A B
BH
Select a timer mode to use for
• NO TIMER
A B
Press
%
6. Switching timer mode
MODE SET
PH
BH
%
A B
Press
A B
Minimum value is held on the display
MODE SET BH
MODE SET
MODE SET PH
BH
• BOTTOM HOLD PH
Select a value to be displayed in the digital display (green) by using or .
To do this, switch the monitor to display received light intensity.
6
Page 7
Initializing Settings (Initial Reset)
Selecting Channels
All settings can be reset to their original values (factory defaults). This can be done only when the operation button is not locked.
The LV Series can perform two different types of sensitivity settings. MODE SET
1 In the state of the received light intensity display, press S five times, while pressing M .
PH
BH
3 Release M .
One of the two channel indicators will start flashing.
is displayed on the digital LED monitor, press S
While tuning sensitivity or setting modes such as power mode, it is not possible to select channels.
Point once. (When is pressed here instead of S , the monitor returns to the received light intensity display without being reset)
Selecting Output Mode
MODE SET PH mode starts flashing.
%
A B
2 When
BH
%
Three types of output modes can be selected.
A B
3
MODE SET BH
Switch
MODE SET PH is displayed on the setting monitor for three seconds and then is displayed. Initialization is now complete. The received light intensity display will appear on the monitor again.
PH or quickly while holding down M .
2 Channel indicator for set up
%
A B
MODE SET PH
BH
1 Press
PH
A B
BH
Output B
L.ON (Output ON when light is received)
%
A B
L.ON D.ON (Output ON when (Output ON when light is received) light is interrupted)
Output switches
MODE SET
%
BH
Output A
D.ON (Output ON when light is interrupted)
%
A B
Key Lock
Initial settings
The operation button can be locked to prevent anyone accidentally touching the operation button and changing settings.
Output A / Output B
„ Turning on Key Lock
Standard light intensity setting*1
OFF
Power mode*2
TURBO
Detection methods
Standard output 1
Display shift
Shift value: 0
Hold mode
No hold display
Timer mode
No timer
Timer
10 ms
Press
„ Releasing Key Lock Press
Output setting for three seconds or more while pressing M .
or will start flashing on the display.
for three seconds or more while pressing M .
or will start flashing on the display. When Key Lock is on, all settings except selecting display, selecting output and display settings remain disabled until Key Lock is released.
Adjusting Sensitivity via External Signals (External Tuning)
D. ON: 46, L. ON: 50 (52 for LV-H62)
This is the function of the LV-11A/21A/21AP. You cannot use this function with LV-51M/51MP.
*1: LV-51M/52/51MP/52P only *2: For LV-51M/52/51MP/52P, FINE only
1 Lock the operation button Point
MODE SET
The value for the timer is only effective when timer mode is set to a setting other than "NO TIMER (OFF)."
PH
Error Messages
Important
If any of the following errors appear on the LED display, check the amplifier or sensor unit according to the countermeasures listed below. Error message
Problem description
Countermeasures brK
The sensor head is not connected, sensor is inserted in a wrong connector, or the sensor head cable has an open circuit.
Check for an open circuit in the head cable, and that the sensor is connected to the correct connector.
Excessive current in output cable.
Check the load and adjust to within rated values.
Data error
Perform the initial reset.
ouLd Err
BH
%
A B
The operation button must be locked to perform external tuning.
2 Connect the pink cable to a switch or PLC. 3 Making a short circuit between the pink cable and blue cable has the same effect as pressing S . LV-21A/11A
LV-21AP Brown
Brown +V Blue
0V
Pink
+V Pink
0V
Blue
If an error message other than the above is displayed, contact KEYENCE. Point
7
Minimum input time is 20 ms.
LV Series-IM_E
Page 8
Caution on usage of QL (LV-20A only) Important
Mutual Interference Suppression The LV Series is equipped with a mutual interference suppression function. Please note, however, that this mutual interference suppression function will not work when two main units are used together.
• When you want to monitor the received light intensity in a PLC using the KEYENCE QL-R01, note that the indication will be limited in the range of 0 to 4095, and that the threshold value that can be written in LV using the QL-R01 is up to 4095 (common to all of FINE, TURBO and SUPER TURBO). • Monitoring of the received light intensity and writing of the threshold value using QL-R01 are possible in the LV-20A only. • Up to eight expansion units can be mounted on the QL-R01 provided all the expansion units are the LV-20A. Refer to "Mounting additional amplifier" (page 4) and the instruction manual for the QL-R01. • LV requires two QL channels because a single LV unit has two output channels. • Restrictions due to compliance with EMC Directive: When linking four LVs or more to the QL-R01, install a ferrite core to the root of the QL-R01 cable.
Point
When additional sensor head units are installed, mutual interference suppression allows the units to be positioned close together. The number of units with which mutual interference suppression will work depends on the selected power mode. Power mode No. of units free
FINE Not possible
TURBO 2*
SUPER 4*
* Total (main unit plus expansion units
Interruption of Laser Radiation A short circuit between the purple and blue conductors will cause laser radiation to be interrupted (min. input time: 20 ms). LV-11A/21A/51M
LV-21AP/51MP
12-24 V DC Brown
Purple
Main circuit
Main circuit
5 V DC
Purple
Brown (Short circuit current 1 mA max.)
Point
(Short circuit current 2 mA max.)
This function is available only with the main unit. Even when expansion units (LV-22A/22AP/52/52P) are connected, laser radiation stops only from the main unit.
Specifications Amplifier unit NPN output
Model
PNP output
LV-21A
LV-22A
LV-20A
FDA (CDRH) 21CFR Part1040.10
Class II Laser Product
Class I Laser Product
Class II Laser Product
IEC60825-1
Class 2 Laser Product
Class 1 Laser Product
Class 2 Laser Product
Main unit/expansion unit
Main unit
Expansion unit (1 line)
Main unit
Main unit
Expansion unit (1 line)
FINE : 80 μs TURBO: 500 μs SUPER: 4 ms
280 μs to 4.7 ms(1)
Operation mode
Output display x 2, Digital LED monitor (light intensity monitor, setting monitor), Bar LED monitor, Laser ON alarm indicator STANDARD 1, STANDARD 2, UP edge, DOWN edge, separate settings for ch A/B (Except the mode in which the standard light intensity setting is in progress) OFF DELAY/ON DELAY/ONE SHOT, separate settings for ch A/B, timer 1 to 9999 ms variable
Indicators Detection modes Timer function
Stop during laser radiation, input time: at least 20 ms.(Main unit only) Input time: at least 20 ms (LV-51M/51MP do not support this item)
Laser emission stop input External tuning input
NPN open-collector x 2 ch, max. 100 mA (40 V max.), residual voltage 1 max. PNP open-collector x 2 ch, max. 100 mA (30 V max.), residual voltage 1 max.
NPN output PNP output
Analog output for monitor Protection circuit
1 to 4 V voltage output, 1 to 4 V across load resistance of at least 20 kΩ for FINE indication 0 to 3000 (LV-51M/51MP only) Reverse-polarity protection, overcurrent protection, surge absorber DC 12 to 24V ±10% max., Ripple (P-P) 10% max.(3)
Power voltage Power consumption (current consumption)
1.5 W (12 V:125 mA, 24 V:62.5 mA) -10 to +55 °C (14 to 131 °F), No freezing(4) 35 to 85%, No condensation
Ambient temperature Relative humidity
10 to 55 Hz, 1.5 mm double-amplitude in X, Y, and Z direction: 2 hours per axis Main body & cover: Polycarbonate
Vibration resistance Materials Weight (incl. 2-m cable) (1) (2) (3) (4)
Expansion unit (0 line)
FINE: 500 μs TURBO: 2 ms SUPER: 8 ms LIGHT-ON/DARK-ON (switch selectable)
FINE: 80 μs TURBO: 500 μs SUPER: 4 ms
Response time
Environmental resistance
LV-52
LV-51MP LV-52P LV-H100/H110/H300
Laser Class
Rating
LV-51M
LV-H41/H51
Supported sensor head
Control output(2)
LV-11A
LV-21AP LV-22AP LV-H32/H35/H37/H42/H47/H52/H62/H64/H65/H67/H35F/H62F
Approx. 120 g
Approx. 75 g
Approx. 35 g
Approx. 120 g
For use with FS-R0 as main unit. If you wish to use the QL-R01 as the main unit, contact KEYENCE. No control output cable for LV-20A The power for LV-20A/22A/22AP/52/52P is supplied from the main unit. With additional units connected, the allowable ambient temperature range varies as follows. 2 to 5 units connected: -10 to +50°C (14 to 122°F) 6 to 7 units connected: -10 to +45°C (14 to 113°F) To connect additional units they must be mounted on a DIN rail (metal DIN rail). Make sure that output current is 20 mA. max. Note also that the expansion unit cannot be used as it is.
LV Series-IM_E
8
Approx. 120 g
Approx. 75 g