General Purpose Digital Laser Sensor LV Series Instruction Manual
Manual10 pagesPDF 11 MB
Instruction manual for the KEYENCE LV series digital laser sensors, amplifiers and sensor heads such as the LV-H32: wiring, tuning, specs.
Covers · 1 model
The models it covers
Summary
What is in it
The instruction manual for the KEYENCE LV series general purpose digital laser sensors, covering the amplifier units (such as LV-21A, LV-22A and LV-51M) and sensor heads (including the LV-H32). It gives laser safety information and labels, part names and accessories, input/output circuit diagrams, mounting amplifiers on DIN rail and attaching sensor heads, sensitivity tuning methods, display and mode settings (power mode, detection mode, hold and timer), initial reset, channels, output mode, key lock, external tuning, error messages, mutual interference suppression and specifications.
Its parts
- Safety Information for LV Series
- Part Names
- Accessories
- Input/Output Circuit Diagram
- Mounting Amplifiers
- Mounting the Sensor Head
- Sensitivity Adjustment
- Differentiation Mode
- Fine Adjustment of Setting Values
- Selecting Display Modes
- Mode Setting
- Initializing Settings (Initial Reset)
- Error Messages
- Selecting Channels
- Selecting Output Mode
From the manual
Key facts from this manual
Each line names its page in the PDF.
Instruction manual for the Keyence LV Series general purpose digital laser sensors. It covers the LV-21A, LV-22A, LV-20A, LV-21AP, LV-22AP, LV-11A, LV-51M, LV-52, LV-51MP and LV-52P amplifiers and a range of sensor heads including the LV-H32. It shows how to mount the amplifiers and heads, tune sensitivity, change settings and read error messages, with specifications for each unit.
- Detection distance
- LV-H32: FINE 30 to 250 mm, TURBO 30 to 500 mm, SUPER 30 to 1000 mm p. 9
- Light source
- LV-H32: visible red semiconductor laser, 660 nm; output 3.0 mW (FDA), 1.0 mW (IEC); pulse duration 3.5 μs p. 9
- Laser class
- The manual states the LV-H32 is a Class II laser product (FDA) and Class 2 (IEC60825-1) p. 1, 9
- Amplifiers
- LV-H32 works with the LV-21A, LV-22A, LV-20A, LV-21AP and LV-22AP amplifiers p. 9
- Beam spot
- LV-H32: spot size set with a focus ring, then fixed with the focus lock screw p. 2
- Head environment
- LV-H32: -10 to +55°C (14 to 131°F), no freezing; 35 to 85% RH, no condensation; incandescent light 10,000 lx max., sunlight 20,000 lx max. p. 9
- Head accessories
- LV-H32: plastic driver, mounting bracket with board nut and two M3 x 18 screws p. 3
- Amplifier power
- 12 to 24 V DC ±10%, ripple (P-P) 10% max.; 1.5 W (12 V: 125 mA, 24 V: 62.5 mA) p. 8
- Amplifier outputs
- NPN open-collector x 2 ch, max. 100 mA (40 V max.); PNP open-collector x 2 ch, max. 100 mA (30 V max.) p. 8
- Error codes
- brK: head not connected, wrong connector or open head cable; ouLd: excess output current; Err: data error, do an initial reset p. 7
- Expansion units
- Up to 7 LV-22A, LV-52 or AP-V42 units beside a main unit (LV-11A/21A/51M), on a DIN rail p. 4
- Modes and timer
- Detection modes STANDARD 1, STANDARD 2, UP edge, DOWN edge; timer OFF DELAY, ON DELAY or ONE SHOT, 1 to 9999 ms p. 8
- Interference suppression
- FINE: not possible; TURBO: 2 units; SUPER: 4 units (main plus expansion units) p. 8
What this manual walks you through
- Mounting amplifiers on a DIN rail and adding expansion units p. 4
- Shortening the sensor head cable and refitting the connector p. 4
- Setting sensitivity by two-point, maximum, automatic or positioning tuning p. 5
- Switching display modes p. 5
- Resetting all settings to factory defaults p. 7
- Choosing the output mode and locking the keys p. 7
- Tuning sensitivity from an external switch or PLC p. 7
- Stopping laser emission with an external input p. 8
- Using the LV-20A with the QL-R01 link unit p. 8
Good to know
- The sensor is for detecting objects only and must not be used to protect a person. p. 1
- Do not stare into the direct or reflected beam, and keep the beam path away from eye height. p. 1
- With extra amplifiers attached the allowed temperature narrows: -10 to +50°C for 2 to 5 units, -10 to +45°C for 6 to 7. p. 8
- Install a head connector no more than two times; after that a new OP-27934 is needed. p. 4
- Do not use the LV Series outdoors or where outside light can shine straight onto the receiving surface. p. 10
Questions this manual answers
Which amplifier works with the Keyence LV-H32 sensor head?
The manual lists the LV-21A, LV-22A, LV-20A, LV-21AP and LV-22AP amplifiers for the LV-H32. p. 9
How do I adjust the beam spot size on the LV-H32?
Turn the focus ring to set the spot size, then turn the focus lock screw to fix it. p. 2
What does brK mean on a Keyence LV amplifier display?
The sensor head is not connected, is in the wrong connector, or its cable has an open circuit. p. 7
How do I reset an LV Series amplifier to factory defaults?
With the received light intensity shown, press S five times while holding M, then press S once more to confirm. The buttons must not be locked. p. 7
What is the detecting range of the LV-H32?
30 to 250 mm in FINE, 30 to 500 mm in TURBO and 30 to 1000 mm in SUPER mode. p. 9
Contents
Chapters and sections
Each line opens the PDF at its page.
- Safety Information for LV Series1
- Part Names2
- Accessories2
- Input/Output Circuit Diagram3
- Mounting Amplifiers4
- Mounting the Sensor Head4
- Sensitivity Adjustment5
- Differentiation Mode (page 6)5
- Fine Adjustment of Setting Values5
- Selecting Display Modes5
- Mode Setting6
- Initializing Settings (Initial Reset)7
- Error Messages7
- Selecting Channels7
- Selecting Output Mode7
- Key Lock7
- Adjusting Sensitivity via External Signals (External Tuning)7
- Caution on usage of QL (LV-20A only)8
- Mutual Interference Suppression8
- Interruption of Laser Radiation8
- Specifications8
- Specifications9
- Hints on Correct Use10
- Cautions on Usage the LV-H100/H110/H30010
- WARRANTIES AND DISCLAIMERS10
The whole text · 2 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file