Page 211
Chapter 9
Specifications
Camera Model
Image pickup element
System Reading Size No. of pixels Pixel shape
Electronic shutter Lens mount method Ambient temperature Environment Relative humidity Weight
CV-070 Inter-line transfer type color CCD Progressive (all reading) 1/3 inch 350,000 pixels Square-pixel/RGB filter 1/30, 1/50, 1/60, 1/100, 1/125, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000 sec. C mount 0 to +40˚ C (32 to 104° F) 35 to 85%, No condensation Camera: Approx. 310 g (including 3 m cable)
9
197
Page 212
Chapter 9
Specifications
9.2 Dimensions Controller: CV-701(P) Unit: mm 47.2 45.2 43
162 2- ø4-4 Mounting hole
150
4
(52) When memory card is attached
20.7 37.3
53.2 100
100 35.4 112
8.7
2
4.4
3.9
4.4
(70)
Remote control console: OP-30938 Accessory: CV-701(P) only R2 44
23 3
12
18 12
9 103
6.5
ø4.5 Cable length: 3 m
198
ø11
Unit: mm
Page 213
Chapter 9
Specifications
Controller: CV-751(P) Unit: mm
(191) (Dimension of mounting bracket) 5
175 22.3
111 (Effective display area)
59.2 57.2 55 Panel thickness 1.2 to 4.0 mm
(63.7) When memory card is attached Mounting bracket Mounting screw
23.2 25
60 83 (Effective display area) 130
(60)
Panel cutout for CV-751(P) controller Unit: mm
169+10
207
124 +10
9
190
199
Page 214
Chapter 9
Specifications
Camera: CV-070 Unit: mm 10
42.8
ø6.6 Cable length: 3 m
8-M3 Depth: 4 max.
8
30
32
ø28 18
30
30
1/4-20UNC Depth: 5 max.
12 15
10
When plastic fitting (accessory) is attached. 1/4-20UNC Depth: 6 max. 2-M3 Depth: 5 max.
2-M4 Depth: 5 max.
18
14.7
10 40
24.8 31 34.9
Close-up adapters (Option: OP-35406) Unit: mm 0.5
1
5 4
10
1 inch 32UN
4
22
1 inch 32UN
4
1 inch 32UN
Lens Unit: mm
■ 3.5 mm lens: CV-L3
9
2
M1.7
3
*Focus ring lock screw *Diaphragm ring lock screw
43 P0.75
CU1 Crest32 ø32
3.5mm
ø45
1:1.6
146° 80°
37.5
200
17.526
Page 215
Chapter 9 ■ 6 mm lens: CV-L6
Specifications
A B
37
17.526 4
1.4 engraving position
CU1 Crest 32 ø29.4 ø32
6mm
ø32.8 ø32 30.5 P0.5 37°
1:1.4
Isopleths
90° A-A
B-B 12.8 19
Focus ring lock screw
Diaphragm ring lock screw A B
■ 16 mm lens: CV-L16 24.5 4
17.526 4.4
ø30 A B
ø30
1.6 engraving position
ø16 CU1 Crest 32
16mm
ø29.3 27P0.5
1 : 1.6
Isopleths
37°
90° 7.5 12.1
A-A
B-B
A B Diaphragm ring lock screw
Focus ring lock screw
■ 50 mm lens: CV-L50
A
Focus ring lock screw
B Diaphragm ring lock screw
12.4 5.5
3-M1.7
1.8 engraving position 95°
ø32 30.5 P0.5
50mm 1:1.8
120°
CU1 Crest 32
120° A-A
37
Model Focal distance Diaphragm Point-blank range Mount Filter screw diameter Weight
B-B
17.526
A
9
105°
3-M1.7 4
Isopleths
B
CV-L3 3.5 mm F1.6 to CLOSE 0.1 m C mount
CV-L6 6 mm F1.4 to CLOSE 0.2 m C mount
CV-L16 16 mm F1.6 to CLOSE 0.4 m C mount
CV-L50 50 mm F1.8 to CLOSE 1.0 m C mount
43.0 mm P0.75
30.5 mm P0.5
27.0 mm P0.5
30.5 mm P0.5
Approx. 90 g
Approx. 70 g
Approx. 44 g
Approx. 55 g
201
Page 216
Chapter 9
Specifications
TFT color monitor (Option: CV-M30) Unit: mm Panel thickness 1.0 to 2.0 mm 125
Mounting bracket Mounting screw
137 (Dimension of mounting bracket) 51
123 83 (Effective display area)
20° 40°
130
90° 7
111 (Effective display area)
52
160 175 (Dimension of mounting bracket)
Panel cutout for CV-M30 TFT color monitor Unit: mm 189
124 +10
155 +10 158
9 Display screen size LCD panel
Matrix size Color Drive system
Environment Weight
202
320 x 3 (H) x 240 (V) Full color TFT active matrix system 1.0 V p-p 75 Ω
Video input Rating
5.5 inch, 111.36 (H) x 85.52 (V) mm
Power supply voltage
24 VDC ± 10%
Current consumption
700 mA max.
Ambient temperature
0 to +40° C (32 to +104° F)
Relative humidity
35 to 85%, No condensation Approx. 570 g
Page 217
Chapter 9
Specifications
Ring lamp (Option: CV-R11) ■ Illuminator * When mounting bracket (L) is attached. (Cable length: 2 m) Unit: mm 41.5 23
33
Camera mounting hole
4- M2.5 x R4
ø48 14.821.23074
ø92
48
36 55 69 ø90
ø90
16
40
15 42.5
98
Amplifier 140
110
Unit: mm
40
8 15
15
110
15
Mounting bracket (S)
2.8
15
80
20 15
22
Unit: mm
16 R1.6 16.8 23.2 30
14 20
Lighting system Luminous color of lamp Lamp dimensions Average service life 1. Initial average luminance 2. Luminance stability Power supply voltage Rating Current consumption Ambient temperature Environment Relative humidity Weight
Illuminator Amplifier
Inverter type high-frequency light (25 to 35 kHz) N-EX (daylight-balanced) Outer diameter: 80 mm, inner diameter: 56 mm. Approx. 2000 hrs. (Luminance deteriorates to 70%.) 800 lx ±10% (250 mm below the lamp center) ± 1.5% for the variation of 100 VAC ±10% 24 VDC ±10% (50/60 Hz common) 20 VA +5 to +50° C (+41 to 122 ° F) 35 to 90%, No condensation Approx. 150 g (including diffuser and mounting bracket) Approx. 650 g (including cable)
1. The average service life is the normal life expectancy of a lamp before the initial luminance deteriorates to 70%, with continuous use under an ambient temperature of 25°C (and in a vibrationfree environment. 2. The initial average luminance is the luminance of a lamp in mint condition.
203
9
Page 218
Chapter 9
Specifications
Mounting stand for CV-751(P) (Option: OP-35481) Unit: mm
17
30
13
7
100
B-B Cross section 173
7.1 28.6 57 16.4 47.4
17 13.5
99.7 4.1
4.6 10 14.1
28.5 12.3
B
B 70°
79
9
204
Page 219
Appendices This section describes general troubleshooting procedures, a list of optional parts, and an index. Appendix A General Troubleshooting .................................... 206 Appendix B Optional Parts List ............................................... 208 Appendix C Index ..................................................................... 210 Appendix D Sample Sheets for Setup Menu .......................... 213 Appendix E Sample Sheets for Testing.................................. 215
Page 220
Appendices
Appendix A General Troubleshooting Troubleshooting Symptom
Probable Cause
Corrective action
Power supply does not turn on. No image appears on the monitor.
The power cable is not connected correctly. The power supply exceeds the specific range. The monitor cable is not connected correctly.
Connect the power cable correctly. Use the power supply within the specific range. Turn off the power and then connect the monitor cable correctly. Remove the lens cover.
The lens cover is not removed. The lens diaphragm is not adjusted properly. The power supply is not turned on.
Appendices
Adjust the lens diaphragm properly. Turn on the power. Use the power supply within the specific range. The camera cable is not Turn off the power and then connected correctly. connect the camera cable correctly. The monitor is not adjusted Adjust the brightness, hue, correctly. etc. The lens focus and Adjust the focus and The menu diaphragm are not adjusted diaphragm. appears, but no properly. image appears. An abnormal The shutter speed is not Set the proper shutter image appears. suitable. speed. The lens and CCD lightClean the lens and CCD receiving surface are not light-receiving surface with clean. an air duster. The remote control The remote control console Turn off the power, and then console does not is not connected correctly. connect the console operate. correctly. The control selector is not Set the control selector to set to the console. the console. RS-232C The communication cable is Turn off the power, and then communication is not connected correctly. connect the communication disabled cable correctly. A proper communication Check the wiring and cable is not used. connect a proper cable. The communication protocol Change the communication is not set properly on the protocol on the PC. PC. Judgment The output unit is not Refer to the output circuit result/numeric connected correctly. and connect the output unit value is not correctly. output. The CV-701(P)/751(P) is not Slide the console slide set to RUN mode. switch to set RUN mode. The tolerance is not set Set the tolerance correctly. correctly. The window does not Retry the settings beginning enclose the target properly. from the screen registration. If targets deviate often, use the position adjustment function. The illumination is not Use a stable illumination stable. lamp designed for image processing.
206
Reference page 11 196 12 – 13 13
12 14 13 *1 –
12 11 181 181 180
165 *2 *3
*4
15