Page 131

Chapter 4 Parameter

Description

Function

ANG

Set the tolerance for the angle.

Set the tolerance for the angle

FIT

Set the tolerance for the correlation ratio.

Set the tolerance for the correlation ratio.

Set the scaling value for analog output.

Output the measured value with the desired output voltage.

Processing time display

Check the processing time.

ANALOG

Setting

Setting Procedure

DATA H ANALOG H DATA L ANALOG L

T=000000

RAW SCR

RAW SCR*

The actual image captured Check the unprocessed by the camera. image.

PROCES1

Processed image for detection.

Check the detection condition.

PROCES2

Processed image for detection.

Check the detection condition.

4

121

Page 132

Chapter 4

Setting Procedure ■ Edge “*” indicates the initial setting value.

Parameter WIND• 1

Setting WIND• 1* to 4

Description Window No.

Change the window No. to set several windows. Use the pattern search method for position detection.

PATT* MENU (Search menu)

Function

Select the search method. Use the edge detection method for position detection.

EDGE

CAM1 SEL SCRN

CAM2

Select the camera image for screen registration.

When two cameras are connected.

Refer to sub menu 3 "Color Menu" (page 123) for detailes.

Set the colors to be extracted.

Extract colors for detection.

X

Set the range to detect the Detect (adjust) the position edge in the X-axis of a pattern only in the Xdirection. axis direction.

Y

Set the range to detect the Detect (adjust) the position edge in the Y-axis of a pattern only in the Ydirection. axis direction.

X+Y

Set the range to detect the Detect (adjust) the position edges in both the X- and of a pattern in both the XY-axis directions. and Y-axis directions.

X>Y

Detect (adjust) the position Set the range to detect the of a pattern in both the Xedges in both the X- and and Y-axis directions by Y-axis directions. first using the edge in the X-axis direction.

Y>X

Detect (adjust) the position Set the range to detect the of a pattern in both the Xedges in both the X- and and Y-axis directions by Y-axis directions. first using the edge in the Y-axis direction.

CAM1|2 CAM1/2

4 COLOR

EDGEMODE

COORD WINDOW X SCAN EDGE SEN

Set the range, scanning direction, and detection sensitivity of the X window.

Set the X window for the edge search.

COORD WINDOW Y SCAN EDGE SEN

Set the range, scanning direction, and detection sensitivity of the Y window.

Set the Y window for the edge search.

DATA

Measured value display

Check the measured value.

COORD (Coordinate)

Use the absolute coordinates on the screen as the numerical value output.

DEV (Deviation)

Use the deviation from the registered screen as the numerical value output.

TOL

122

Page 133

Chapter 4 Parameter

Setting X=0000 =0000

Setting Procedure

Description

Function

Set the tolerance for the distance of the X coordinate.

Set the tolerance for the X coordinate.

Set the tolerance for the distance of the Y coordinate.

Set the tolerance for the Y coordinate.

Set the scaling value for analog output.

Output the measured value with the desired output voltage.

Processing time display

Check the processing time.

COORD Y=0000 =0000

ANALOG

DATA H ANALOG H DATA L ANALOG L

T=000000 RAW SCR*

The actual image captured Check the unprocessed by the camera. image.

PROCES1

Processed image for detection.

Check the detection condition.

PROCES2

Processed image for detection.

Check the detection condition.

PROCES3

Processed image for detection.

Check the detection condition.

4

RAW SCR

3. Color menu “*” indicates the initial setting value.

Parameter

Setting

Description

Function

Select the color extraction settings.

Change the extraction methods or copy the settings of other windows.

COLOR1 COLOR2 CLR TYPE GRAY WIND• 1 to 4 SELECT

Move the cursor on the screen to select the colors To extract the colors. to be extracted.

SEN

Use the cursor to set the sensitivity for the color range when selecting the extraction colors.

Change the color range to be extracted in one operation.

IGNORE

Select colors not to be extracted.

Omit selected colors from those extracted.

AUTO

Automatically extend the range for color extraction.

Stabilize the color extraction.

SCRN REG N/Y

Register the reference image.

Save the target image in the memory.

LEVEL

Select a level for color extraction.

Manually select a level for color extraction.

Select a filter. (Reference: For details, see page 131.)

Omit the noise or optimize detection.

FILTER

0 to 9 (5*)

11 types

123

Page 134

Chapter 4

Setting Procedure

4.10.2 “REL.POS” Menu Menu structure The parameters of 2 and 3 are the same as the [ABS.POS] menu. 2. Window menu

1. Main menu No.00 MODE REL.POS

SHUTTER SCRN REG

REF WND MENU PATT

4

CAM1 CAM2

REF WND MENU SEL SCRN COLOR PW SW SRCH SPD SRCH SEN ANG ADJ

REF WND REL•1 REL•2 REL•3

DATA TOL ANG= FIT= ANALOG

ARE/CON INS/TRG INS+POS ABS.POS REL.POS

PATT EDGE

3. Color menu CLR TYPE COLOR1 SELECT SEN=5

IGNORE AUTO SCRN REG

DATA

OPTION

SAVE T= RAW SCR

124

SVD SCRN ILLU DATA CAL

WIND•1 MENU SEL SCRN COLOR EDGEMODE X WINDOW X DATA TOL COORD X= = Y= = ANALOG

PATT EDGE X Y X+Y X>Y X<Y COORD DEV

LEVEL FILTER

COLOR1 COLOR2 GRAY REF WND REL 1 REL 2 REL 3

Page 135

Chapter 4

Setting Procedure

4.10.3 Advanced position adjustment setting (Pattern search) This section describes the setting procedure for accurate position adjustment.

[SRCH SPD] (Search speed) Set the speed and resolution of the search. • • •

The initial setting is [NORMAL]. The processing time becomes longer as the setting is changed from [FAST] to [NORMAL], and then to [SUB_PIX] (Sub pixel). The [SUB_PIX] setting enables detection with a high resolution of 0.1 pixels.

1. Place the cursor on [SRCH SPD] in the window menu and press the [ENT] key. The [SRCH SPD] (Search speed) menu appears.

SW SRCH SPD SRCH SEN 2. Place the cursor on the desired option and press the [ENT] key to confirm the selection for [SRCH SPD].

SRCH SPD FAST NORMAL SUB PIX

Tips

The processing time is displayed at the bottom of the menu screen (T=000000). Check the value after changing the setting.

[SRCH SEN] (Search sensitivity) Change the sensitivity of the search when the search is unstable or fails. • •

The initial setting is [AUTO]. The sensitivity of the search increases and the stability of detection enhances as the setting is changed from [OBJT1] to [OBJT2], then to [AUTO], [FINE1], and [FINE2]. OBJT1

Rough search

Faster

Fine search

Slower

OBJT2 AUTO FINE1 FINE2

125

4

Page 136

Chapter 4

Setting Procedure Note 1: When [OBJT1] or [OBJT2] is selected under [SRCH SEN], the maximum size of a pattern window is 256 x 256 pixels. [GRAVITY] (Gravity) mode searches the image for the position of the center of gravity and its angle of principal axis of the binary-converted extracted color data (The horizontal axis of the screen and the longitudinal axis of the smallest ellipse enclosing a cluster of extracted colors form the angle of principal axis.) Binary conversion processing speeds the processing; however, detection will be unstable under the following conditions due to the operation principles. Gravity

Note 2: When the cluster of extracted colors spreads across the MEASURE window. Note 3: When two or more clusters with a similar size exist in the MEASURE window. Note 4: When the principal axis is not determined. (e.g. square and circular objects)

4

1. Place the cursor on [SRCH SEN] in the window menu and press the [ENT] key. [SRCH SEN] menu appears.

SRCH SPD SRCH SEN ANG ADJ 2. Place the cursor on the desired option and press the [ENT] key to confirm the selection for [SRCH SEN].

SRCH SEN OBJT1 OBJT2 AUTO FINE1 FINE2

Tips

126

Increasing the SERCH SEN value slows the processing time. Do not set the sensitivity higher than it needs to be.

Page 137

Chapter 4

Setting Procedure

4.10.4 Advanced position adjustment setting (Edge detection) Selecting the edge detection mode There are five modes for edge detection. In any mode, the screen is searched in the direction set with “SCAN” for edge detection. 1. Place the cursor on [MENU] in the window menu and press the [ENT] key. The search menu appears.

WIND•1 MENU SEL SCRN 2. Place the cursor on [EDGE] and press the [ENT] key. The message <ERASE SETTINGS N/Y> appears on the screen. Place the cursor on “Y” and press the [ENT] key.

4

MENU PATT EDGE 3. Place the cursor on [EDGEMODE] mode and press the [ENT] key.

COLOR EDGEMODE X WINDOW X 4. Select the desired mode and press the [ENT] key.

EDGEMODE X Y X+Y X>Y Y>X X: To adjust the position only in the X-axis direction.

X window

Y: To adjust the position only in the Y-axis direction.

Y window

127

Page 138

Chapter 4

Setting Procedure X+Y: To adjust the position in both X- and Y-axis directions. Y window X window

X>Y: To adjust the position in the X-axis direction first, and then adjust the position in the Y-axis direction. Y>X: To adjust the position in the Y-axis direction first, and then adjust the position in the X-axis direction. Tips

4

Priority position adjustment • Example: X priority (X>Y) mode When the X priority mode is selected, the X coordinate of the edge is searched in the X window. The result (the difference between the registered X coordinate value and the detected X coordinate value) is used to shift the Y window, and then the Y coordinate of the edge is searched.

X edge Y window Registered screen

Y window is shifted.

• When the preferred edge position is extremely different from the registered position and the shifted window disappears from the screen, the detection result is unacceptable regardless of the coordinate value.

The Y window is shifted off the screen.

128

Page 139

Chapter 4

Setting Procedure

WINDOW X and WINDOW Y settings WINDOW X/WINDOW Y : Set a window to search in the X-axis/Y-axis direction with [COORD]. The screen is searched in the horizontal/vertical direction. Set the direction of the edge search with [SCAN]. Use the [▲]/[▼] cursor to change the setting.

EDGEMODE X WINDOW X

•

WINDOW X COORD 100, 220 400, 260 SCAN BL→WH EDGE SEN 030

X window

Search direction

Y window

Search window

[BL] ← [WH]

Right to left

[BL] ← [WH]

Bottom to top

[WH] ← [BL]

Right to left

[WH] ← [BL]

Bottom to top

[WH] → [BL]

Left to right

[WH] → [BL]

Top to bottom

[BL] → [WH]

Left to right

[BL] → [WH]

Top to bottom

4

[EDGE SEN]: Set the sensitivity of the edge detection. Setting range: 000 to 100 (Initial setting: 030) A smaller value increases the sensitivity so that edges are detected with a smaller difference in the brightness. Set the optimal sensitivity while watching the monitor.

4.10.5 Advanced position adjustment (Tolerance setting) [TOL] (Tolerance) Select the coordinates or the deviation to set the edge tolerance. [COORD] : Use the absolute coordinates to display the measured value and to set the tolerance. [DEV] : Use the difference from the reference value (registered screen) to display the measured value and to set the tolerance. 1. Place the cursor on [TOL] in the window menu and press the [ENT] key.

TOL ANG=±010 FIT= 00 2. Place the cursor on [COORD] or [DEV] and press the [ENT] key.

TOL COORD DEV

129

Page 140

Chapter 4

Setting Procedure

4.10.6 Sensitivity adjustment for edge detection Adjusting the sensitivity for edge detection When detection is unstable (e.g. some edges are not detected or unnecessary edges are detected), adjust the sensitivity to optimize detection. 1. Place the cursor on [WINDOW X] in the window menu and press the [ENT] key.

WINDOW X COORD 100, 220 400, 260 SCAN BL→WH EDGE SEN 030

4

2. Place the cursor on [EDGE SEN] and press the [ENT] key. The first digit of the sensitivity is shown as highlighted.

EDGE SEN 030 3. Change the value for the [EDGE SEN] using the [ENT] key. •

•

The change in the values for [EDGE SEN] is reflected in the edge detection status on the monitor screen. Set the optimal sensitivity while watching the monitor. A larger value decreases the sensitivity, and a smaller value increases the sensitivity. CAM1 CAM2 PROGRAM WIND•1 INSPECT OUTER SCRN REG COLOR SCAN MEASURE EDGE SEN 035 DATA +0.000 TOL H=+0.000 L= +0.000 ANALOG T= RAW SCR

130